REPAIR HVAC BUILDING 550
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Georgia |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Aug 22, 2025 |
| Due Date: | Sep 23, 2025 |
| Solicitation No: | FA670325B0005 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Original)
- Original Published Date: Aug 22, 2025 05:36 am EDT
- Original Date Offers Due: Sep 23, 2025 02:00 pm EDT
- Inactive Policy: 15 days after date offers due
- Original Inactive Date: Oct 08, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
Marietta , GA 30069USA
This project will replace the outside air damper for AHU 1 & 2, install a modulating actuator on AHU 1 & 2 outside air damper. Install an outdoor air humidity and outside air temperature sensor to AHU 1 & 2. Replace AHU2 supply fan motor and VFD to match the new 15hp motor. Replace AHU 3 DX cooling coil with a chilled water coil that meets the existing coil specs. Install new black iron chilled water piping from AHU3 to connect to existing chilled water loop. Install a new modulating 3-way valve at AHU3 chilled water coil. Install two new chilled water pumps with new electrical disconnects and starters in AHU 1 & 2 mechanical room. Replace damaged AHU 3 duct and insulation. Replace all plunger type VAV’s with damper type and all perimeter VAV’s are to have reheating coils. All HVAC control components need to be connected to the existing HVAC control system, programmed and functional in accordance with Dobbins Design Guide. This project will comply with UFC 1-200-01, UFC 3-410-01, and other applicable UFCs, installation architectural standards, and local building codes.
- ADMIN ONLY NO REQTN CP 678 655 5783 1538 ATLANTIC AVE BLDG 812
- DOBBINS AFB , GA 30069-4900
- USA
- Kevin Song
- kevin.song@us.af.mil
- Phone Number 6786553695
- Kenneth J. Jacob
- kenneth.jacob.1@us.af.mil
- Phone Number 6786555745
- Aug 22, 2025 05:36 am EDTSolicitation (Original)
Related Document
| Aug 7, 2025 | [Presolicitation (Original)] Repair HVAC Building 550 |
See Also
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-77021-NONST-2027-000000197
State Government of Georgia
Due by 9/17/2026
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-66418-NONST-2026-000000023
State Government of Georgia
Due by 10/07/2026
B2932 - Resurfacing Contract 2027-1 Local Roads (Northwest) ADVERTISEMENT FOR BIDS 2022 TRANSPORTATION
Cobb County
Due by 9/24/2026
Event ID Event Title Government Entity Start Date (ET) End Date (ET) PE-66397-NONST-2027-000000018
State Government of Georgia
Due by 10/01/2026