6150--631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Massachusetts |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Dec 5, 2024 |
| Due Date: | Dec 20, 2024 |
| Solicitation No: | 36C24125R0038 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Dec 05, 2024 02:07 pm EST
- Original Response Date: Dec 20, 2024 01:00 pm EST
- Inactive Policy: Manual
- Original Inactive Date: Mar 29, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6150 - MISCELLANEOUS ELECTRIC POWER AND DISTRIBUTION EQUIPMENT
-
NAICS Code:
- 238210 - Electrical Contractors and Other Wiring Installation Contractors
-
Place of Performance:
Department of Veterans Affairs VA Central Western Massachusetts HCS Leeds , 01053USA
The purpose of this notice is to determine if there are qualified SDVOSBs or VOSBs, WOSBs, and Small Businesses that have the experience with this type of work and if such firms are interested in this procurement. The magnitude of construction is between $1,000,000 and $5,000,000. The NAICS code is 238210 and the small business size standard is $19 Million. Interested firms should indicate their interest to the Contracting Officer no later than 1:00 PM EST December 20, 2024, via email to Brian.Kelly@va.gov.
The following information is required in response to this notice:
(1) A positive statement of your intention to submit a proposal in response to a solicitation for this project and include your firm s name (as it appears in SAM.gov) SAM UEI number, and socio-economic status of the firm (i.e., verified SDVOSB or VOSB, WOSB, SB, or Large Business);
(2) Provide examples of two (2) projects within the past five (5) years that contain the following criteria:
(A) Renovating and installing campus electrical panels over 200 amps;
(B) Phasing plan for electrical panel replacement in a healthcare facility;
(3) Provide examples of two (2) projects within the past five (5) years that contain the following criteria
(A) Programming, installing and upgrading building metering;
(B) Circuit tracing, rerouting existing circuits and new interior electrical installations;
(4) Provide examples of two (2) projects within the past five (5) years that contain the following criteria
(A) Renovating and installation of automatic transfer switches within healthcare setting;
(5) Prime shall provide proof of insurance and bonding for a construction project of this magnitude.
Interested firms shall hold active SAM registration. Visit www.sam.gov to register in this database.
SDVOSB or VOSB firms shall be certified by Veterans Small Business Certification (VetCert) (Veterans Small Business Certification (sba.gov).
All information must be submitted in sufficient detail for a decision to be made on the availability of interested firms. Failure to address all information requested in addition to the below form will result in a contractor not being considered as an interested concern. If adequate interest is not received by 1:00 PM EST on December 20, 2024, this action will not be set-aside for SDVOSBs, VOSBs, WOSBs, or Small Business firms. Interested firms must reply via e-mail to Brian.Kelly@va.gov with the title Response to Sources Sought Correct Deficiency Generator Buildings 1WA, 1EA . DISCLAIMER
This sources sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this notice.
Project Example Template
Firm:
Project title:
Location:
Award amount:
Final amount:
Description of project Addressing the Following:
(2) Provide examples of two (2) projects within the past five (5) years that contain the following criteria:
(A) Renovating and installing campus electrical panels over 200 amps;
(B) Phasing plan for electrical panel replacement in a healthcare facility;
Description of project Addressing the Following:
(3) Provide examples of two (2) projects within the past five (5) years that contain the following criteria
(A) Programming, installing and upgrading building metering;
(B) Circuit tracing, rerouting existing circuits and new interior electrical installations;
Description of project Addressing the Following:
(4) Provide examples of two (2) projects within the past five (5) years that contain the following criteria
(A) Renovating and installation of automatic transfer switches within healthcare setting;
- ONE VA CENTER
- TOGUS , ME 04330
- USA
- Brian Kelly
- Brian.Kelly@va.gov
- Phone Number 413-584-4040 x6722
- Dec 05, 2024 02:07 pm ESTSources Sought (Original)
Related Document
| Jan 13, 2025 | [Sources Sought (Updated)] 631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA |
| Mar 12, 2025 | [Presolicitation (Original)] N061--631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA |
| Apr 16, 2025 | [Presolicitation (Updated)] N061--631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA |
| Apr 29, 2025 | [Presolicitation (Updated)] N061--631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA |
| May 9, 2025 | [Presolicitation (Updated)] N061--631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA |
| May 9, 2025 | [Sources Sought (Updated)] 631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA |
| Aug 4, 2025 | [Presolicitation (Updated)] N061--631-18-003 Correct Deficiency Generator Buildings 1WA, 1EA Award Notice |
See Also
Header Information Bid Number: BD-27-1293-MAR15-MAR15-133100 Description: 25kV 1000 kCMIL Copper Conductor Bid Opening
Commonwealth of Massachusetts
Due by 10/09/2026
Bid Solicitation: BD-23-1044-EPS90-1044E-80657 Responses Due in 3690 Days, 20 Hours, 48 Minutes Header
Commonwealth of Massachusetts
Due by 11/24/2032
Header Information Bid Number: BD-27-2233-SRTA-STRA-132989 Description: Electric Vehicle Charger Station EVCS Installations RFP
Commonwealth of Massachusetts
Due by 10/09/2026