C1DZ--631-25-002 Renovate B2 for Pharmacy SF330 Requests for Qualifications Full and Open
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Massachusetts |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jun 4, 2025 |
| Due Date: | Jun 11, 2025 |
| Solicitation No: | 36C24124R0106 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
- Contract Opportunity Type: Special Notice (Updated)
- Updated Published Date: Jun 04, 2025 11:52 am EDT
- Original Published Date: Nov 21, 2024 03:38 pm EST
- Updated Response Date: Jun 11, 2025 01:00 pm EDT
- Original Response Date: Dec 30, 2024 01:00 pm EST
- Inactive Policy: Manual
- Updated Inactive Date: Oct 08, 2025
- Original Inactive Date: Apr 08, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: C1DZ - ARCHITECT AND ENGINEERING- CONSTRUCTION: OTHER HOSPITAL BUILDINGS
-
NAICS Code:
- 541310 - Architectural Services
-
Place of Performance:
Leeds , MA 01053USA
631-25-002 Renovate Building 2 for Pharmacy RFIs Received Paragraph A. INTRODUCTION on page 1 indicates that the scope to be performed consists of interior spaces, however the design service list on page 3 indicates that Building 2 is part of the Northampton Veterans Administration Hospital Historic District and therefore care must be made with exterior changes to remain close to historical appearances. Please clarify, does scope include exterior improvements or is all work expected to be interior for the Building 2 renovation? VA Response: Some exterior work expected. SOW has following line items regarding exterior: Review and design of building egress pathways (i.e., entry doors, rear doors, ADA ramps, emergency egress stair towers, etc.) Review of exterior walls to improve envelope performance. Repairing the building envelope will be a part of this design as there are known issues with the masonry, windowsills and lintels, and other infrastructure. Replacement of existing windows. Professional Qualifications listed on page 6 state that the design firm must provide a Physical Security team member and resume as part of the submission. Please advise if this a low-voltage security designer or otherwise. The role of Physical Security is a bit ambiguous. VA Response: Physical Security team member must be familiar with the PSRDM and meet the qualifications in section 1.8 of the manual: In order to meet the physical security and resiliency requirements of this manual, as appropriate to the scope of the project, the design team must include: (1) a certified physical security specialist with an emphasis on risk and vulnerability assessments, physical security design and CPTED, and anti-terrorism force protection; (2) a control systems cybersecurity specialist with in-depth knowledge of the Risk Management Framework; (3) a certified physical security specialist with an emphasis on Electronic Security Systems; (4) certified information and communications technology (ICT) specialist with an emphasis on networking and cabling; (5) a certified systems integrator specialist with an emphasis on HSPD/PPD-21 integrations; and, (6) a licensed professional structural engineer who has specialized training in blast design and analysis (structural blast specialist). These specialists must be part of the design team during the concept phase of any project. The résumé of the specialist must be submitted to the VA Project Manager (PM), local facility equivalent, or Contracting Officer Representative for review and approval prior to the concept phase of the project. The qualifications of the firm for whom the specialist works must also be submitted with the résumé. The professional qualifications that all specialists must comply with PHYSICAL SECURITY & RESILIENCY DESIGN MANUAL October 1, 2020 Revised 05-01-2024 INTRODUCTION 1-23 are found where their respective disciplines are addressed in Chapters 2, 6, 7, and 10 of this manual. Does the VA hire the Fire Protection engineer for the independent fire review or is that a consultant that should be included? VA Response: The VA provides the Fire Protection Engineer for the Independent Fire Review. See section 2.2 which states, [a] complete design including but not limited to determination and evaluation of existing conditions, necessary engineering calculation, necessary design work, independent fire safety/life safety review (Independent Fire Safety Review provided by VA. A/E is required to address comments from this review), IH Services, quantity and cost estimates, bid schedule, construction cost estimates, a proposed construction schedule, design analyses and calculations, a design documentation report, engineering considerations and options report shall be developed for this project.Â
- ONE VA CENTER
- TOGUS , ME 04330
- USA
- Brian Kelly
- Brian.Kelly@va.gov
- Phone Number 413-584-4040 x6722
- Jun 04, 2025 11:52 am EDTSpecial Notice (Updated)
- May 16, 2025 10:02 am EDT Special Notice (Updated)
- May 15, 2025 11:15 am EDT Special Notice (Updated)
- Apr 08, 2025 11:55 pm EDT Special Notice (Updated)
- Dec 18, 2024 10:38 am EST Special Notice (Updated)
- Nov 30, 2024 12:00 am EST Sources Sought (Original)
- Nov 22, 2024 11:43 am EST Special Notice (Updated)
- Nov 21, 2024 03:38 pm EST Special Notice (Original)
Related Document
See Also
Bid Solicitation: BD-18-1020-DCRCU-DC250-28443 Header Information Bid Number: BD-18-1020-DCRCU-DC250-28443 Description: Fire Management Planning Services
Commonwealth of Massachusetts
Due by 12/25/2027
RFP A/E design services High St. Veterans roof replacement
Brookline Housing Authority
RFP for HR Services (Due by October 5, 2026 by 12:00pm) 703 Washington
Town of Holliston
Due by 10/05/2026
10 Walnut Geotechnical and Environmental Engineering RFP
Brookline Housing Authority