Z2LZ--Replace Parking Lot Gates for Fisher House
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Florida |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Aug 13, 2025 |
| Due Date: | Aug 18, 2025 |
| Solicitation No: | 36C24825Q1022 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- Updated Published Date: Aug 13, 2025 11:15 am EDT
- Original Published Date: Jul 29, 2025 10:21 am EDT
- Updated Date Offers Due: Aug 18, 2025 03:00 pm EDT
- Original Date Offers Due: Aug 08, 2025 03:00 pm EDT
- Inactive Policy: Manual
- Updated Inactive Date: Oct 17, 2025
- Original Inactive Date: Oct 07, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: Z2LZ - REPAIR OR ALTERATION OF PARKING FACILITIES
-
NAICS Code:
- 812930 - Parking Lots and Garages
-
Place of Performance:
Department of Veterans Affairs James A. Haley Veterans' Hospital Tampa , FL 33612USA
Fisher House Gates (RFQ# 36C24825Q1022)
Amendment 0001
The following questions were asked of the Government relating to the subject requirement which are hereby posted and responded to.
Q&As:
All cabling must be included.
Question:
Answer:
How far away is the power source? Approximately 150 ft.
How far is the control panel away from the barriers? Approximately 300 ft.
Is there pathways available to use for new cabling or will new conduit and trenching be needed in order to pull cabling? There are pathways available. Existing wire may be used if verified working with no shorts in circuit.
Are there any drawings of the site for reference? Yes, I will attach a drawing to this email.
Bollards must be installed to protect the arms from vehicle damage.
Question:
Answer:
Are there any specifications for these bollards? Diameter, height, color, style, manufacturer. I don t have any specs on the bollards. I would say equivalent to what is there. Diameter is about 6 in., height is about 5 ft., color is safety yellow, style is tough, no specific manufacturer.
How many are required per arm? Two bollards total. One in front of the pedestal and one behind the pedestal. They are to protect the pedestal that the card reader is on. We also need the pedestal to be replaced.
Card reader must be tied to CCure 9000 security system.
Question:
Answer:
We are not an access control company so will we be terminating to the existing system or will the access control company perform that effort? Relay and card reader wire currently exists at location. Contractor will be required to make terminations into system. Electronics will be available to identify wiring.
Do you have any other specifications on the type of card reader? Needs to have 200-bit Federal Agency Smart Credential Number (FASC-N) card format encryption and compatible with C-Cure. Current examples used at our facility are Wave Lynx ET20-3PS and HID pivCLASS RP40-H.
What type of card should the reader use? PIV card.
Do we need account for any cards? No.
Who will be responsible for programming current badges to the system? VA staff will be responsible for programming.
Question: Extension of due date and attached blueprint.
Answer: Quotes must be emailed to Walida.MooreSaintil@va.gov and received No Later Than Monday, August 18th, 2025, by 15:00 pm EST on the close date.
- 8875 HIDDEN RIVER PARKWAY
- TAMPA , FL 33637
- USA
- Walida Moore-Saintil
- Walida.MooreSaintil@va.gov
- Phone Number 813-631-2856
- Aug 13, 2025 11:15 am EDTCombined Synopsis/Solicitation (Updated)
- Jul 29, 2025 10:21 am EDT Combined Synopsis/Solicitation (Original)
Related Document
| Jul 29, 2025 | [Combined Synopsis/Solicitation (Original)] 5660--Replace Parking Lot Gates for Fisher House |
See Also
Notice: 31252156 Notice of Bid/Request for Proposal Department: EXPRESSWAY AUTHORITIES Division: Greater Miami
Florida Department of State
Due by 9/21/2026
Project ID: Y25-726-MB Title: Orange County Traffic Signal Upgrade Phase I and Phase
Orange County
Due by 9/17/2026
Indian River Elementary - Replace Switchgear Bldg. 4 - Project No. 2648222 Mandatory
Volusia County Schools
Due by 10/15/2026
Follow KC-46A ADAL Apron and Hydrant Fueling Pits Active Contract Opportunity Notice ID
DEPT OF DEFENSE
Due by 9/29/2026