Z1DA--632-16-101 UPGRADE EMERGENCY GENERATORS - PHASE I
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Dec 2, 2024 |
| Due Date: | Jan 7, 2025 |
| Solicitation No: | 36C24225R0007 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Updated)
- Updated Published Date: Dec 02, 2024 10:31 am EST
- Original Published Date: Nov 26, 2024 08:13 am EST
- Updated Date Offers Due: Jan 07, 2025 11:00 am EST
- Original Date Offers Due: Dec 09, 2024 11:00 am EST
- Inactive Policy: Manual
- Updated Inactive Date: Feb 06, 2025
- Original Inactive Date: Feb 07, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: Z1DA - MAINTENANCE OF HOSPITALS AND INFIRMARIES
-
NAICS Code:
- 236220 - Commercial and Institutional Building Construction
-
Place of Performance:
EVALUATION FACTORS
Please describe your recent experience with multi-generator, paralleled emergency power systems in clinical healthcare facilities. Please include recent, not to exceed three project profiles of these similar projects completed in the past five years. Please include the project location, initial magnitude, planned and actual construction durations, total change order amount, any post-construction callbacks, any challenges and lessons learned, and a contact for the client who is familiar with the project.
Please describe your approach and phasing of work to construct the project. What would you consider the critical path? Please include written narrative and any supporting documents such as pictures, drawings, etc., taking into consideration long lead equipment and how it will be implemented into the projects schedule, any electrical power disruptions and their durations, any required temporary provisions, and maintenance of existing facility operations.
  Â
Please describe your recent experience with the construction of new buildings to house emergency power systems and/or building infrastructure systems, preferably in clinical healthcare facilities. Please include recent, not to exceed three project profiles of these similar projects completed in the past five years. Please include the project location, initial magnitude, planned and actual construction durations, total change order amount, any post-construction callbacks, and a contact for the client who is familiar with the project.
Please describe your recent experience retrofitting existing low voltage switchgear and its electrical components in occupied facilities, preferably in clinical healthcare facilities. Please include three project profiles of these similar projects completed in the past five years. Identify what manufacturer and type of switchgear was retrofitted and with what type of retrofit kit. Please include the project location, initial magnitude, planned and actual construction durations, total change order amount, any post-construction callbacks, any challenges and lessons learned, and a contact for the client who is familiar with the project.
Please describe your recent experience replacing automatic transfer switches in occupied clinical healthcare facilities. Please include three project profiles of these similar projects completed in the past five years. Please include the project location, initial cost, planned and actual construction durations, total change order amount, any post-construction callbacks, any challenges and lessons learned, and a contact for the client who is familiar with the project.
Please describe your recent experience with replacing underground fuel storage tanks and constructing new underground fuel oil storage systems, preferably in clinical healthcare facilities. Please include recent, not to exceed three project profiles of these similar projects completed in the past five years. Please include project location, initial cost, planned and actual construction durations, total change order amount, any challenges and lessons learned, and any post-construction callbacks.
Please describe who is your subcontractor on this job and what experience do you have working together? Provide a short narrative of any recent project collaborations you and this key subcontractor have partnered on.
- 113 HOLLAND AVE
- ALBANY , NY 12208
- USA
- Lester S Griffith
- Lester.Griffith@va.gov
- Dec 02, 2024 10:31 am ESTSolicitation (Updated)
- Nov 26, 2024 08:13 am EST Solicitation (Original)
Related Document
| Oct 23, 2024 | [Presolicitation (Original)] Z1DA--632-16-101 UPGRADE EMERGENCY GENERATORS - PHASE I |
| Nov 26, 2024 | [Solicitation (Original)] Z1DA--632-16-101 UPGRADE EMERGENCY GENERATORS - PHASE I |
| Dec 9, 2024 | [Solicitation (Updated)] Z1DA--632-16-101 UPGRADE EMERGENCY GENERATORS - PHASE I |
| Jan 3, 2025 | [Solicitation (Updated)] Z1DA--632-16-101 UPGRADE EMERGENCY GENERATORS - PHASE I |
| May 1, 2025 | [Award Notice (Original)] Z1DA--632-16-101 UPGRADE EMERGENCY GENERATORS - PHASE I |
See Also
Follow Bradbury Dam Outlet Valve Replacement Active Contract Opportunity Notice ID 140R2026R0018 Related
INTERIOR, DEPARTMENT OF THE
Due by 9/17/2026
Historic Schoolhouse Renovation Gautier, September 17, 2026 11:00 am
Goodwyn Mills Cawood(GMC)
Due by 9/17/2026
Follow OA?Donnell Dam Stabilization and Erosion Control Active Contract Opportunity Notice ID 140L6426R0001
INTERIOR, DEPARTMENT OF THE
Due by 10/02/2026
Follow Z--GRSM ROAD STRIPING Active Contract Opportunity Notice ID 140P5326R0022 Related Notice Department/Ind.
INTERIOR, DEPARTMENT OF THE