Z2DA--623-23-121 Reroof portions of various Bldgs (53.24.1E) Construction (VA-26-00004686)
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Oklahoma |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Aug 4, 2025 |
| Due Date: | Aug 15, 2025 |
| Solicitation No: | 36C25925R0097 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Aug 04, 2025 09:57 am CDT
- Original Response Date: Aug 15, 2025 10:00 am CDT
- Inactive Policy: Manual
- Original Inactive Date: Nov 22, 2025
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: Z2DA - REPAIR OR ALTERATION OF HOSPITALS AND INFIRMARIES
-
NAICS Code:
- 238160 - Roofing Contractors
-
Place of Performance:
Department of Veterans Affairs Jack C. Montgomery VA Medical Center Muskogee , OK 74401USA
Re-Roof Portions of Various BLDGs (53, 24, 1-E) Pt 4; 623-23-121, at the Jack C. Montgomery VA Medical Center in Muskogee, OK
36C25925R0097
The Department of Veteran Affairs has a requirement for a Contractor provide all required labor, material, equipment, and site investigations to perform partial reroofing construction on buildings 24, a portion of Building 1-E Wing that connects to Building 24 and Building 1-C Wing, two lower roofs on Building 53 and Building 24 stairwell. This degradation has led to unwanted water leaking into the facility. The Contractor shall provide acceptable electronic services for submittal and document exchange for both design and construction, i.e. Submittal Exchange . Work includes construction period services, site visits, and acceptance inspections by a qualified inspector. Construction includes the following items:
Firms shall be properly licensed and bonded to perform general contracting work in the State of Oklahoma or have equivalent licensing and be approved for such work by the Veteran s Administration.
This project will require the removal and replacement of existing roof systems which shall include: re-roof with new TPO roof system; replace all perimeter and penetration flashings; remove all unnecessary penetrations; replace all roof drain hardware, rings, gutters, and downspouts; lightening protection system on building 53, 24, and 1E shall have the aggregate, roofing membrane, and insulation removed down to the roofing deck. New insulation of R-33, high-density coverboard, and TPO membrane will be installed in all locations. The concrete roof decks will receive a vapor barrier bellow the insulation, and the metal decks will have a substrate board to cover the fluted deck. Building 24 and 1E shall have multiple opening in the concrete roof patched. Multiple vent fans and exhaust fans shall be replaced.
The contractor shall store all material offsite and only bring in up to 3 days worth of material on site. A crane shall NOT be allowed on bldgs. 24, 1E, and 53 due to being 24-hour operations and not being able to shut down.
Approximate areas:
BLDG 24 - 3340 ft2
BLDG 24 Corridor - 1350 ft2
BLDG 52 Outdoor Pavilion - 1750 ft2
BLDG 53 Above ER - 1400 ft2
Building 54 has been pulled out of the construction and is not part of the project.
It is to be documented in the construction documents that the prime construction contractor shall provide engineering and technical support, all manuals, wiring diagrams, and tools necessary for adjusting, maintaining, repairing, and testing of equipment for use by VA engineering staff or VA s designated Maintenance Provider.
The above requirements for design will also apply to construction and shall be in accordance with ADA, OSHA, and NFPA requirements. It is to be documented in the construction documents that the prime construction contractor shall provide engineering and technical support, all manuals, wiring diagrams, and tools necessary for adjusting, maintaining, repairing, and testing of equipment for use by VA Engineering staff or VA s designated Maintenance Provider. Construction Prime Contractor shall provide one year of maintenance and inspection service following beneficial use as specified and required within the specifications of this project. The space conditions and the execution of this project shall proceed with minor interference to the operation of the medical center and shall comply with all requirements for infection control, utility interruptions, fire protection, and all other safety requirements of the contract.
The NAICS code for this procurement is 238160 with a small business size standard of $19M. The magnitude of this project is between $1,000,000.00 and $2,000,000.00. This project will be 100% set-aside for Service-Disabled Veteran-Owned Small Businesses, as stated below.
The POC for this project will be Angela Waalkes and she can be contacted by email at angela.waalkes@va.gov
Important Notice: Apparent successful offerors must apply for and receive verification from the Department of Veterans Affairs Center for Verification and Evaluation (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control enough to establish appropriate status. Offerors must be both VISIBLE and VERIFIED by the Department of Veteran Affairs CVE at the time of offer submission. Failure to be both VERIFIED by CVE and VISIBLE on SBA s VetBiz at the time of offer submission and contract award, will result in the offeror s proposal being deemed non-compliant. All offerors are urged to contact the CVE and submit the required documents to obtain CVE verification of their SDVOSB status if they have not already done so.
- 6162 S WILLOW DR SUITE 300
- Greenwood Village , CO 80111
- USA
- Angela Waalkes
- angela.waalkes@va.gov
- Phone Number 303-712-5781
- Aug 04, 2025 09:57 am CDTPresolicitation (Original)
Related Document
| Sep 16, 2025 | [Solicitation (Original)] Z2DA--623-23-121 Reroof portions of various Bldgs (53.24.1E) Construction (VA-26-00004686) |
| Oct 9, 2025 | [Solicitation (Updated)] Z2DA--623-23-121 Reroof portions of various Bldgs (53.24.1E) Construction (VA-26-00004686) |
| Oct 28, 2025 | [Solicitation (Updated)] Z2DA--623-23-121 Reroof portions of various Bldgs (53.24.1E) Construction (VA-26-00004686) |
| Dec 30, 2025 | [Award Notice (Original)] Z2DA--623-23-121 Reroof portions of various Bldgs (53.24.1E) Construction |
See Also
Project Number - SP 21-8 Project Title - Mohawk Filter Press Building Roof
City of Tulsa
Due by 10/16/2026
Follow Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM -
VETERANS AFFAIRS, DEPARTMENT OF
Follow WWYK200270 CNSLD Demo Convert Space to Drug Testing Office, B7037 Active Contract
DEPT OF DEFENSE
Follow 697DCK-26-R-00355: OKC ATCT Full-Service Elevator Maintenance Active Contract Opportunity Notice ID 697DCK-26-R-00355
TRANSPORTATION, DEPARTMENT OF
Due by 10/26/2026