Z1AZ--Elevator Repair at Dayton VAMC
| Agency: | |
|---|---|
| State: | Ohio |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jun 22, 2026 |
| Due Date: | Jun 30, 2026 |
| Solicitation No: | 36C25026Q0673 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Jun 22, 2026 03:08 pm EDT
- Original Response Date: Jun 30, 2026 03:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Jul 15, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: Z1AZ - MAINTENANCE OF OTHER ADMINISTRATIVE FACILITIES AND SERVICE BUILDINGS
-
NAICS Code:
- 238290 - Other Building Equipment Contractors
-
Place of Performance:
Dayton VAMC Dayton , OH 45428USA
The purpose of this notice is to gain knowledge of interest and qualifications of elevator repair businesses.
BACKGROUND. The only elevator servicing the two-story Fisher House (Bldg 425) at Dayton VAMC is not serviceable. It was damaged during a lightning storm.
The elevator was manufactured by OTIS and is identified as H25701.
The elevator was evaluated by an OTIS certified technician and two defects were noted:
An I/O board was damaged and cannot be replaced, it must be repaired.
The CPU is damaged and must be replaced.
Contractor must confirm discrepancies and troubleshoot, if needed, to return the elevator to service.
SCOPE
Provide all labor, materials, and services necessary to facilitate the repair of the damaged I/O board, including packaging and shipment to an authorized repair facility. Replacement I/O boards are obsolete and unavailable; therefore, repair is required. Furnish and install one (1) new CPU board. Upon return and installation of the repaired I/O board and the new CPU board, perform all adjustments required to restore proper system functionality. All materials furnished and all work performed shall comply with the ASME A17.1 Safety Code for Elevators and Escalators. Upon completion, adjust the elevator for proper operation and conduct a full fire recall test to verify compliance and performance.
All work shall be performed by technicians certified to service OTIS elevators.
ANY INTERESTED PARTIES who can provide the services described are requested to submit the following information:
Company name, address and point of contact with phone number,
SAM Unique Entity Identifier (UEI),
Documentation substantiating OTIS certification,
Identify if your business has an existing contract vehicle that can be ordered against (e.g. GSA Advantage). If so, please provide the FSS contract number.
Any other pertinent information.
Send submissions via email to Brian.Rosciszewski@VA.gov.
Firms that respond to this Sources Sought notice but do not provide ALL the requested information may not be considered by the Government when making acquisition decisions.
This is not a solicitation for proposals. No contract will be awarded from this notice.
No proposals are being requested or accepted with this notice.
This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation.
Please be advised that the government will not pay any costs for responses and information submitted.
Respondents may not be notified of the results of this notice; it is at the discretion of the Government to release any results.
Note: Interested parties must be registered in SAM (System for Award Management) to be eligible for the award of a Government contract.
- VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
- DAYTON , OH 45428
- USA
- Brian Rosciszewski
- Brian.Rosciszewski@VA.gov
- Phone Number 937-268-6511
- Jun 22, 2026 03:08 pm EDTSources Sought (Original)
Related Document
| Jul 8, 2026 | [Combined Synopsis/Solicitation (Updated)] Repair Elevator - Bldg 425 Dayton VAMC (Services) |
| Jul 10, 2026 | [Combined Synopsis/Solicitation (Updated)] Repair Elevator - Bldg 425 Dayton VAMC (Services) |
| Jul 15, 2026 | [Combined Synopsis/Solicitation (Updated)] Repair Elevator - Bldg 425 Dayton VAMC (Services) |
| Jul 31, 2026 | [Award Notice (Original)] Z1AZ--Elevator Repair Bldg 425 -Services |
See Also
Follow Renovation/Repair of Bldg 27 at DSCC, OH Active Contract Opportunity Notice ID
DEPT OF DEFENSE
Due by 9/17/2026
Solicitation Type Description Close 26-07-155 RFQ ADA Entrance Modification Project at Bellaire Puritas
Cuyahoga Metropolitan Housing Authority
Due by 9/18/2026
Solicitation ID: SRC0000041428 Solicitation Name: PWC Headlands Beach Roof Replacement Two Restrooms Original
State Government of Ohio
Due by 9/18/2026
Publish Date Due Date Number Owner Contractring Authority Project Name Primary Service Estimated
Ohio Facility Construction Commission
Due by 9/15/2026