Z2AA - Renovate Historic Building 4
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | North Carolina |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Dec 13, 2024 |
| Due Date: | Jan 4, 2025 |
| Solicitation No: | 36C24624R0030 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Updated)
- Updated Published Date: Dec 13, 2024 11:24 am EST
- Original Published Date: Nov 12, 2024 11:53 pm EST
- Updated Date Offers Due: Jan 04, 2025 03:00 pm EST
- Original Date Offers Due: Dec 13, 2024 03:00 pm EST
- Inactive Policy: Manual
- Updated Inactive Date: Jun 12, 2025
- Original Inactive Date: Jun 12, 2025
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
-
NAICS Code:
- 236220 - Commercial and Institutional Building Construction
-
Place of Performance:
Fayetteville , NC 28301USA
This project consists of a complete renovation of the existing Historic Building 4 for administrative space and offices along with necessary support and utility requirements. This is designated as Mission Critical and must comply with VA Physical Security and Resiliency Design Manual (PSRDM) requirements for Mission Critical structures as incorporated in this design and the specifications. The project provides an addition for an elevator with access to all levels, and addresses life safety egress issues with the addition of code-compliant stairwells. Exterior renovations of the historical building will be renovated per National and State Historic Preservation Office (SHPO) requirements outlined in the specifications and drawings. The project will modernize the space with the most current level of technology and design including all new mechanical, plumbing, electrical, and fire protections systems. This design was created using Revit and Building Information Modeling (BIM) and all efforts post construction award shall be required to use Revit level of detail (LOD) 300 or higher. The Revit drawings will only be made available to the contractor awarded this project.
This project does require asbestos and lead abatement.
There are underground existing utilities and installations this contactor shall relocate.
There is mobilization and project area located at the building, but pedestrian and vehicle traffic ways must be kept open for facility use. Any additional space required may be remote on the facility or the contractor shall have to find a location off station but will not be compensated by the VA.
See specification section 01 35 26 Safety Requirements for detailed requirements of the Site Superintendent, SSHO, and Quality Control Manager.
The contractor shall provide a mobilization plan along with all other required plans prior to being allowed on this station. MOB plan shall address all temporary utility measures, fence/gates, contractor parking, temporary signage/project signage, materials storage, dumpsters and any other details as requested by the VA COR.
- 100 EMANCIPATION DR
- HAMPTON , VA 23667
- USA
- Wayne Goodmond
- wayne.goodmond@va.gov
- Phone Number 910 824 9189
- Dec 13, 2024 11:24 am ESTSolicitation (Updated)
- Nov 14, 2024 02:18 pm EST Solicitation (Updated)
- Nov 12, 2024 11:54 pm EST Solicitation (Updated)
- Nov 12, 2024 11:53 pm EST Solicitation (Original)
Related Document
| Nov 13, 2024 | [Presolicitation (Updated)] Z2AA-- Renovate Historic Building 4 Project No: 565-20-101 |
| Nov 13, 2024 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Nov 14, 2024 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Jan 4, 2025 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Jan 11, 2025 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Jan 13, 2025 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Jan 22, 2025 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Jan 31, 2025 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
| Jun 16, 2025 | [Solicitation (Updated)] Z2AA - Renovate Historic Building 4 |
See Also
Solicitation Number: 274-PMSSRR-P1 Project Title: Raleigh Water Program Management for Sanitary Sewer Rehabilitation
State Government of North Carolina
Due by 9/17/2026
Bid Opportunity: RFP: Mason Farm Wastewater Treatment Plant Secondary Clarifier #3 Repairs Pre-Bid
Carrboro OWASA (Water and Sewer Authority)
Due by 9/25/2026
Bid Opportunity: W. Stinson Street Sewer Replacement Pre-Bid Meeting: Non-Mandatory: September 3, 2026
Carrboro OWASA (Water and Sewer Authority)
Due by 9/21/2026
RFB #26-085 Nomaco Park Renovations RFB #26-085 Nomaco Park Renovations (former Five County
Wake County
Due by 9/16/2026