Y1DZ--437-24-101, Replace UST's & Leak Detection System
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | North Dakota |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Mar 2, 2026 |
| Due Date: | Mar 31, 2026 |
| Solicitation No: | 36C26326B0016 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Original)
- Original Published Date: Mar 02, 2026 11:08 am CST
- Original Date Offers Due: Mar 31, 2026 02:00 pm CDT
- Inactive Policy: Manual
- Original Inactive Date: Dec 31, 2026
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: Y1DZ - CONSTRUCTION OF OTHER HOSPITAL BUILDINGS
-
NAICS Code:
- 236220 - Commercial and Institutional Building Construction
-
Place of Performance:
Fargo , ND 58102USA
The Contractor shall furnish all labor, materials, and equipment to replace existing UST’s (Underground Storage Tank) #1, #2, #3, #4, #8, existing AST’s (Aboveground Storage Tank) #4, and #5, along with existing #1, #2, #3, #4, #8, #9 and #10 UST interconnected below-grade piping systems on the Fargo VA campus including designing flexible spill containment liners, tertiary containment barriers, encasement barriers, waterproof manway covers, and Auto Tank Gauges (ATG) with integrated monitoring and reporting. Environmental assessments, soil boring tests and geotechnical drilling at four VA site locations required, along with compliance with physical security and resiliency standards for intrusion and blast protection. A phasing plan to ensure zero downtime for existing backup generators with temporary power solutions shall be proposed & followed. Additional work includes cathodic protection system design, semiautomatic pump clarification systems, and establish control points for future construction
POP: 540 days.
- 316 Robert Street N Suite 506
- Saint Paul , MN 55101
- USA
- Benjamin Woehrle
- benjamin.woehrle@va.gov
- Phone Number 651-293-3071
- Mar 02, 2026 11:08 am CSTSolicitation (Original)
- Feb 22, 2026 11:00 pm CST Presolicitation (Original)
Related Document
| Jan 23, 2026 | [Presolicitation (Original)] Y1DZ--437-24-101, Replace UST's & Leak Detection System |
| Mar 30, 2026 | [Solicitation (Updated)] Y1DZ--437-24-101, Replace UST's & Leak Detection System |
| Mar 31, 2026 | [Presolicitation (Updated)] Y1DZ--437-24-101, Replace UST's & Leak Detection System |
| Apr 24, 2026 | [Award Notice (Original)] Y1DZ--437-24-101, Replace UST's & Leak Detection |
See Also
Follow I Field Project Active Contract Opportunity Notice ID 127EAX26Q0103 Related Notice Department/Ind.
AGRICULTURE, DEPARTMENT OF
Due by 9/23/2026
Follow I Field Project Active Contract Opportunity Notice ID 127EAX26Q0103 Related Notice Department/Ind.
AGRICULTURE, DEPARTMENT OF
Due by 9/23/2026
Follow Industry Feedback for Draft Requirements, Solicitation, and Request for White Papers for
DEPT OF DEFENSE
Due by 9/23/2026
Follow REMOVE AND REPLACE CONCRETE DRAINAGE PAD FOR BUILDING #11 WITH OPTOINS Active
AGRICULTURE, DEPARTMENT OF
Due by 9/23/2026