XTLF 15-1018 Repair AA and E Storage at F527
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Oklahoma |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Jul 29, 2025 |
| Due Date: | Aug 15, 2025 |
| Solicitation No: | FA3029-25-R-0007 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Updated)
- Updated Published Date: Jul 29, 2025 01:51 pm CDT
- Original Published Date: Jul 02, 2025 10:24 am CDT
- Updated Date Offers Due: Aug 15, 2025 10:00 am CDT
- Original Date Offers Due: Aug 15, 2025 10:00 am CDT
- Inactive Policy: Manual
- Updated Inactive Date: Jul 09, 2026
- Original Inactive Date: Aug 30, 2025
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
-
NAICS Code:
- 236220 - Commercial and Institutional Building Construction
-
Place of Performance:
246 Brown Parkway Suite 225, Enid Oklahoma 73705 Enid , OK 73705USA
The purpose of this solicitation is to notify prospective contractors on the performance of construction services for project XTLF 15-1018 Repair AA and E Storage at F527. This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor renovations to eliminate deviation request VANCE AFB 97-01. These renovations include the reinforcement of the existing AA and E storage room by adding steel and plywood layers to surrounding interior walls and ceiling. In addition, existing fixtures will be removed and reinstalled on the new wall and ceiling faces, the entry door will be replaced with a compliant door, and window fasteners will be replaced with compliant tamper-resistant fasteners. Circuits on the interior electrical panel dedicated to other areas of the facility will be relocated to a new panel outside the room, providing better access to emergency personnel. AA and E Risk Categories II through IV must be stored in a structure with a minimum forced entry resistance of 10 minutes against threat severity level III.
- ADMIN ONLY NO REQTN CP 580 213 6770 246 BROWN PKWY STE 228 BLDG 500
- ENID , OK 73705-5037
- USA
- Alexis Bishop
- alexis.bishop.2@us.af.mil
- Phone Number 5802137848
- Thomas Patton
- thomas.patton.1@us.af.mil
- Phone Number 5802136770
- Jul 29, 2025 01:51 pm CDTSolicitation (Updated)
- Jul 02, 2025 10:24 am CDT Solicitation (Original)
Related Document
| Jul 2, 2025 | [Solicitation (Original)] XTLF 15-1018 Repair AA&E Storage at F527 |
See Also
Project Number - SP 21-8 Project Title - Mohawk Filter Press Building Roof
City of Tulsa
Due by 10/16/2026
Follow Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM -
VETERANS AFFAIRS, DEPARTMENT OF
Follow WWYK200270 CNSLD Demo Convert Space to Drug Testing Office, B7037 Active Contract
DEPT OF DEFENSE
Follow 697DCK-26-R-00355: OKC ATCT Full-Service Elevator Maintenance Active Contract Opportunity Notice ID 697DCK-26-R-00355
TRANSPORTATION, DEPARTMENT OF
Due by 10/26/2026