2WS/557WW Demountable Walls
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Nebraska |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Aug 27, 2026 |
| Due Date: | Sep 11, 2026 |
| Solicitation No: | FA460026Q0095 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Presolicitation (Original)
- Original Published Date: Aug 27, 2026 06:00 pm EDT
- Original Response Date: Sep 11, 2026 11:00 am EDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Sep 26, 2026
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: N071 - INSTALLATION OF EQUIPMENT- FURNITURE
-
NAICS Code:
- 238390 - Other Building Finishing Contractors
-
Place of Performance:
Offutt AFB , NE 68113USA
PRE-SOLICITATION
OFFUTT AFB 2WS/557WW Demountable Walls 55 CONS/PKB - FA4600
106 PEACEKEEPER LN, STE 2N3, OFFUTT AFB, NE 68113
27 August 2026
Product/Service Code: N017
NAICS code: 238390
Place of Performance: Offutt AFB, Nebraska
Proposed Set Aside: 100% Total Small Business Set-Aside
DESCRIPTION
55CONS intends to award a sole source, firm-fixed-price contract to Encompass Corporation for the reconfiguration of Haworth Demountable Walls for the 2WS and the 557WW. This notice is not a request for competitive quotes; however, interested parties who believe they can meet the requirements listed below may submit capability statements for consideration. Please see the attached PWS's for further specifications of this requirement.
Summary of Performance Work Statements:
2WS
4.1 Wall Modifications
-
Rooms 1340 & 1342 Partition: Disassemble existing demountable wall panels dividing Rooms 1340 and 1342. Salvage, inspect, and reuse hardware to relocate and install the wall, completely enclosing Room 1342 as an independent space.
-
Room 1332 Reconfiguration: Install new demountable partition walls to divide the current footprint into two (2) fully enclosed offices and a shared communal area, including all ceiling tracks, floor channels, acoustic seals, and trim.
-
Room 1343 Deconstruction: Fully disassemble and remove demountable walls, door frames, and hardware from Room 1343 to restore it to an open-plan layout. Hand over salvaged components to the 557th WW Facility Manager (or legally dispose/recycle as directed).
-
Rooms 1220, 1221, & 1222 Merger: Disassemble and remove the demountable partitions dividing Rooms 1220, 1221, and 1222 to merge them into a single, open-concept footprint. Patch and repair affected ceiling grids, floor surfaces, and adjacent walls.
4.2 Door Installations
The Contractor shall install four (4) 40-inch demountable door panels configured to open inward at the following locations:
-
Room 1342: One (1) door panel.
-
Room 1332: Two (2) door panels (one for each of the newly constructed offices).
-
Room 1332 (from Room 1320): One (1) door panel.
4.3 HVAC (Government Furnished Property/Work)
-
Air Transfer Grilles: Install return air transfer grilles between Room 1340 and the new office space, and between the new offices within Room 1332 to balance static pressure and ensure proper airflow distribution.
-
Note: This specific task (4.3) will be accomplished by the 557th Weather Wing Facilities office and is excluded from the contractor's performance requirements.
B185
The contractor shall perform the following teardown, relocation, and installation tasks:
-
Room L422 Relocation and Reconfiguration:
- Dismantle and move the L423 four (4) West wall panels to the East by approximately 8ft.
- Utilize the existing L422 door and glass panel to establish the new L422 door space.
-
Room L423 Expansion and Reconfiguration:
- Reclaim and integrate existing L423 and legacy L422 demountable panels to expand the designated work area.
- Use on hand demountable wall stock to fill in existing wall gaps to complete the room (~25ft).
- Install double solid wood doors in the Southeast corner of the room, complete with appropriate framing and HAWORTH-compatible commercial hardware. Final door location determined at install (adjust as needed to accommodate install)
-
Room L421 Configuration
- Use existing material stock to install new walls to close in Collaboration and training space. Approximately 25 linear feet of panels, configured as two intersecting runs of approximately 23 feet and 2 feet. Final adjustment allowed during install.
- Extract the legacy L423 door and associate hardware and re-install door to serve as the new entrance for Room L421. TBD during install (Adjustments allowed as needed)
This requirement will be awarded using RFO part 12 Simplified Procedures. The award will be made prior to 30 September 2026.
If you have any questions please reach out via email to A1C Hunter Hendrix (hunter.hendrix.1@us.af.mil) or TSgt Jennifer Prestridge (jennifer.prestridge.1@us.af.mil).
- ADMIN ONLY NO REQTN CP 402 232 6459 106 PEACEKEEPER DR BLDG 3 STE 2N3
- OFFUTT AFB , NE 68113
- USA
- Hunter Hendrix
- hunter.hendrix.1@us.af.mil
- Phone Number 4022945206
- TSgt Jennifer Prestridge
- jennifer.prestridge.1@us.af.mil
- Phone Number 4022946393
- Aug 27, 2026 06:00 pm EDTPresolicitation (Original)
See Also
Post Date 08/21/2026 Quest Number 10338626 Category Code 285 - Electrical Equipment And
City of Grand Island
Due by 9/16/2026