W065--6 Month Lease C-Arm XRAY System BRAND NAME OR EQUAL
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Florida |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Mar 17, 2025 |
| Due Date: | Mar 20, 2025 |
| Solicitation No: | 36C24825Q0546 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Mar 17, 2025 02:54 pm EDT
- Original Response Date: Mar 20, 2025 02:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Apr 04, 2025
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: W065 - LEASE OR RENTAL OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
-
NAICS Code:
- 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
-
Place of Performance:
10,000 Bay Pines Blvd Bay Pines FL 33744 ,
Please direct reply in the affirmative via email if you are interested and can provide the required product for this requirement. Please provide capability statement, I will accept responses for this Sources Sought until the 20th of March 2025 14:00, thanks. 3. Technical Requirements:
Unit physical specifications
R/F unit, mobile type
Full
Image type
Flat panel detector
Minimum detector size [cm]
30 x 30
Minimum central resolution [lp/mm]
2.5
Minimum range of motion orbital rotation [deg]
148
Minimum range of motion pivot rotation [deg]
225
Minimum range of motion panning motion [deg]
12
Minimum range of motion horizontal travel [cm]
20
Minimum range of motion vertical travel [cm]
45
Minimum c-arm depth [in]
28.7
Minimum generator output power [kW]
25
Minimum capacity for images [# of images]
300,000
Minimum image matrix size [pixels]
1952 x 1952
Maximum system dimensions [in]
78 x 33 x 65
Maximum system weight [lbs.]
375
Other physical specifications Additional specifications Flat surface beneath detector to allow for efficient table-top positioning
Image magnification with a minimum of 3 settings
Consistent field of view during rotation
Tube head controls for use by clinician
Foot pedal
Wireless Centering/alignment light for tube head
Reference monitor
Motion and metal detection
Measurement software
Automatic video playback
User-configurable threshold dose warning
Digital image rotation, reversal, and image invert
Selectable mode settings for high-level pulse and low dose
Touchscreen monitor
UPS on board
Automatic brightness stabilization (ABS) control
Remote control for entire unit, mountable on the patient table
Motorization of orbital, angular, and vertical movement.
Advanced applications Digital Subtraction Angiography (DSA)
Pulsed cine Bolus chase imaging with single contrast injection
Roadmap technology for vascular imaging, to include.
Increased frame rate from base model 30fps or greater
Real-time digital subtraction
Road mapping
Increased image storage (1000 images or greater)
Bolus tracking
Vessel measurement tools and calculations
Catheter/guidewire visualization enhancement
Preset vascular profiles
Security/Connectivity requirements OEM-supported operating system
Latest DICOM print, store, commit, structured report (SR) and modality worklist
Encrypted hard drive
PACS compatibility Philips Intellispace
PACS compatibility VA VistA Imaging
OR table compatibility Philips NCVA791 Xper Table Tilt Clinical Training On-site clinical applications training for 2 technologists during go-live
On-site clinical applications training for 2 physicians during go-live
- 8875 HIDDEN RIVER PARKWAY
- TAMPA , FL 33637
- USA
- Michael A Shook
- Michael.Shook@va.gov
- Phone Number 813-972-2000 Ext 2819
- Mar 17, 2025 02:54 pm EDTSources Sought (Original)
Related Document
| Mar 28, 2025 | [Presolicitation (Original)] W065--6 Month Lease C-Arm XRAY System |
| Mar 31, 2025 | [Solicitation (Original)] W065--6 Month Lease C-Arm XRAY System |
| Apr 9, 2025 | [Solicitation (Updated)] W065--6 Month Lease C-Arm XRAY System |
| May 14, 2025 | [Award Notice (Original)] W065--6 Month Lease C-Arm XRAY System |
See Also
Project ID: Title: Multi-Function Device (MFD) Fleet Replacement, Lease, and Cost-Per-Copy Maintenance Services
City of Hollywood
Due by 9/15/2026
Project: RE-BID of On-Airport Rental Car Concessions at Tallahassee International Airport Ref. #:
City of Tallahassee
Due by 9/09/2027
Follow FCC COLEMAN FREEZER TRAILER LEASE Active Contract Opportunity Notice ID 15B30226PR000411 Related
JUSTICE, DEPARTMENT OF
Due by 9/30/2026
Description: TOWELS AND FENDER COVERS, RENTAL OF, TERM CONTRACT Department: Procurement Buyer: Kristen
Palm Beach County
Due by 10/22/2030