6110--Variable Frequency Drive Units VA Connecticut Healthcare System West Haven VA Medical Center
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Connecticut |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Jun 11, 2026 |
| Due Date: | Jun 16, 2026 |
| Solicitation No: | 36C24126Q0551 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- Updated Published Date: Jun 11, 2026 11:36 am EDT
- Original Published Date: Jun 03, 2026 12:46 pm EDT
- Updated Date Offers Due: Jun 16, 2026 12:00 pm EDT
- Original Date Offers Due: Jun 16, 2026 12:00 pm EDT
- Inactive Policy: Manual
- Updated Inactive Date: Jul 01, 2026
- Original Inactive Date: Jul 01, 2026
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: 6110 - ELECTRICAL CONTROL EQUIPMENT
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
VA Connecticut Healthcare System West Haven VA Medical Center West Haven , 06516
Solicitation No.: 36C24126Q0551
Date: June 11, 2026
Purpose of Amendment
The purpose of this amendment is to provide responses to questions submitted regarding the solicitation. As a result of these questions and responses, the response due date will remain unchanged, as June 16, 2026.
Question: For evaluation of technician qualifications, please clarify what documentation the Government expects to be submitted with the quotation (e.g., OEM training certificates, factory certifications, resumes, licenses, OSHA certifications, or other supporting documentation).
Answer: At a minimum. Contractors should provide the following for each technician who may perform work under the contract. Current. Relevant experience, training, and qualifications. OEM manufacturer training certificates applicable to the equipment or systems covered by the contract. Current factory certifications or manufacture authorized service Certifications.
Question: The solicitation states that contractors shall demonstrate that their technicians meet the qualification standards identified in the Performance Work Statement. Can the Government please clarify what information and/or documentation offers are expected to submit to demonstrate technician qualifications for evaluation purposes.
Answer: At a minimum. Contractors should provide the following for each technician who may perform work under the contract. Current. Relevant experience, training, and qualifications. OEM manufacturer training certificates applicable to the equipment or systems covered by the contract. Current factory certifications or manufacture authorized service Certifications.
Question: Provide clarification on the controls scope and can you please confirm whether the new VFDs will be controlled automatically through the existing Johnson Controls BMS? If so, is the contractor responsible for all BAS programming, integration, point mapping, and commissioning associated with the new VFD installations, or will these services be provided by the VA and/or its existing controls contractor?
Answer: The contractors control scope shall be limited to the installation and physical integration of the new VFD control wiring into the existing building automation system infrastructure. The new VFD's are intended to operate automatically through the existing Johnson Controls building automation system. The contractor should provide all required field wiring terminations and coordination necessary to facilitate connection to the VFD to the existing Johnson control system. Upon completion of the field installation, the controls contractor will perform all required programming and software modifications to achieve automatic operation.
- ONE VA CENTER
- TOGUS , ME 04330
- USA
- Yolanda Rankin
- Yolanda.Rankin@va.gov
- Phone Number 978-890-2709
- Jun 11, 2026 11:36 am EDTCombined Synopsis/Solicitation (Updated)
- Jun 03, 2026 12:46 pm EDT Combined Synopsis/Solicitation (Original)
Related Document