Description
- Contract Opportunity Type: Special Notice (Original)
- Original Published Date: Nov 18, 2025 10:11 am PST
- Original Response Date: Nov 21, 2025 08:00 am PST
- Inactive Policy: 15 days after response date
- Original Inactive Date: Dec 06, 2025
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: J020 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIP AND MARINE EQUIPMENT
-
NAICS Code:
- 336611 - Ship Building and Repairing
-
Place of Performance:
Seattle , WA 98134USA
This is for informational purposes only. This has been awarded via JOTFOC
TECHNICAL SERVICES
USCGC POLAR STAR (WAGB-10) – Z14501
SERVICES FOR WOODWARD GOVERNOR CONTROLS
-
Objective. The objective of this requirement is to restore full capabilities to the Woodward governor control equipment for the #2 Main Gas Turbine (MGT). Specifics of the equipment are the following:
-
LQ25 Valve Actuator, Part # 9907-995
- Previous Unit: Serial # 17923576
- Installed Unit: Serial # 17926022
-
Digital Valve Positioner, Part # 8200-507
- Installed Unit: Serial # 22672252
-
LQ25 Valve Actuator, Part # 9907-995
970) 482-5811
-
References. For any listed references to be distributed, the contractor must be registered in the Joint Certification Program (JCP) through Defense Logistics Agency (DLA) and provide your JCP number and expiration date to the listed point of contact (POC) for this work.
- United States Coast Guard Technical Publication: 4390-234-A, GAS TURBINE PROPULSION SYSTEM
- COMDTINST 9077.1 (series), Equipment Lockout/Tags-Plus Process
- Background. This requirement is for the contractor to provide a certified Original Equipment Manufacturer (OEM) technician to perform field troubleshooting on governor control components for the Main Gas Turbine, products of Woodward. When approaching 3600 RPM on the N3 rotor, the turbine controls perform an emergency stop due to a Fuel Driver Fault. The ship’s technicians performed extensive field troubleshooting to attempt resolution of system issues with negative results. The ship technicians replaced the digital valve positioner and LQ-25 with on-board spares. With remote guidance from Woodward technicians, the crew attempted initial set up and configurations, but system remains inoperable due to unfamiliarity with equipment specifics, i.e. diagnostic software used to program components, verifying installation and calibration set up, etc.
-
Tasks. The contractor shall provide labor services and technical expertise for the Woodward LQ25 Valve Actuator, which includes but may not limited to:
- Coordinate field visit and base access with provided points of contact for an Original Equipment Manufacturer (OEM) certified technical representative. Services must be conducted in the presence of designated USCG personnel.
-
Conduct an initial and final operational test of equipment. USCG personnel will operate all shipboard machinery and equipment. USCG personnel will secure and tag applicable equipment prior to the start of any work. If unable to perform an initial operational test due to equipment issues, the requirement may be waived only by the USCG Technical Points of Contact listed in this SOW. The final operational test must be performed to demonstrate satisfactory operation of equipment and resolution of issues.
- Observe safety precautions when working with electrical and electronic equipment. Failure to comply exposes personnel to the danger of electrical shock and personal injury.
-
In accordance with applicable references, the contractor shall groom the Woodward components to identify and correct issues with the equipment for #2 Main Gas Turbine.
- Any additional material and labor (and associated costs) outside the scope of the field visit, or above the not to exceed price, must receive approval from a warranted Contracting Officer (KO) prior to proceeding. The contractor shall submit a Condition Found Report.
- Provide an invoice and trip report including at least the following: service dates and location, issue description with any errors/symptoms, troubleshooting steps, findings, resolution, and recommendations (if any). If parts are needed for additional work, the contractor must provide part number, the quantity needed, price per unit, lead time, and potential source(s) with contact information.
-
Government Furnished Property.
- None.
- Security Requirement. Base access is required. The contractor shall have a valid government issued ID (or driver’s license) and show proper identification at the security gate. The contractor must provide information at least 48 hours in advance for security to process access requests. A USCG representative from the ship or SFLC Product Line can sponsor and escort vendor to the ship.
- Place of Performance. USCGC POLAR STAR at USCG Base Seattle. Address: 1519 Alaskan Way S, Seattle, WA 98134
- Period of Performance. 19-20 November 2025
-
Technical Points of Contact.
- USCG-SFLC-LREPL, Asset Manager: LT Mikael Axelsson, Mikael.J.Axelsson@uscg.mil, (571) 607-1134
- USCGC POLAR STAR, Engineer Officer: LCDR Josh Herring, Joshua.C.Herring@uscg.mil
- USCGC POLAR STAR, Main Propulsion Assistant: CWO Matthew Tuten, Matthew.R.Tuten@uscg.mil
- COAST GUARD ISLAND, BLDG 50-7
- ALAMEDA , CA 94501
- USA
- Justin Wooldridge
- justin.r.wooldridge2@uscg.mil
- Phone Number 2068205327
- Lindsay Mongiovi
- lindsay.n.mongiovi@uscg.mil
- Phone Number 5716086752
- Nov 18, 2025 10:11 am PSTSpecial Notice (Original)
See Also
Follow CALIBRATION AND MAINTENANCE SERVICE BALANCES AND WEIGHING DEVICES Active Contract Opportunity Notice
DEPT OF DEFENSE
Due by 9/15/2026
Follow HVAC Replacement -Mount Baker-Snoqualmie National Forest Active Contract Opportunity Notice ID 1240BJ26Q0052
AGRICULTURE, DEPARTMENT OF
Due by 9/15/2026
SEP Program: Solicitation Name: MBE Bus Fire Suppression System Maintenance SEP %: Solicitation
Washington Metropolitan Area Transit Authority
Due by 10/07/2026
Follow CGC HEALY SPIRAX SARCO STEAM TRAP Active Contract Opportunity Notice ID 70Z08526Q0027750
HOMELAND SECURITY, DEPARTMENT OF
Due by 9/16/2026