Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System
| Agency: | COMMERCE, DEPARTMENT OF |
|---|---|
| State: | Maryland |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jun 12, 2026 |
| Due Date: | Jun 23, 2026 |
| Solicitation No: | 1333ND26QNB680282 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Updated)
- Updated Published Date: Jun 12, 2026 02:04 pm EDT
- Original Published Date: Jun 12, 2026 01:58 pm EDT
- Updated Date Offers Due: Jun 23, 2026 11:00 am EDT
- Original Date Offers Due: Jun 23, 2026 11:00 am EDT
- Inactive Policy: 15 days after date offers due
- Updated Inactive Date: Jul 08, 2026
- Original Inactive Date: Jul 08, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6695 - COMBINATION AND MISCELLANEOUS INSTRUMENTS
-
NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
-
Place of Performance:
Gaithersburg , MD 20899USA
The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.
This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.
- ACQUISITION MANAGEMENT DIVISION 100 BUREAU DR.
- GAITHERSBURG , MD 20899
- USA
- Robert Singman
- robert.singman@nist.gov
- Phone Number 3019756388
- Jun 12, 2026 02:04 pm EDTSolicitation (Updated)
- Jun 12, 2026 01:58 pm EDT Solicitation (Original)
- May 26, 2026 03:59 pm EDT Sources Sought (Original)
See Also
IFB 2027-15 ORGANIC OIL FOR BIOSOLIDS DUST SUPPRESSION SYSTEM A Pre-Bid Conference will
Howard County
Due by 9/23/2026
Follow Octet(r) R4 to Octet(r) R8 Upgrade Active Contract Opportunity Notice ID 75N98026Q01175
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 9/18/2026
Follow Leica M320 Diagnostic ENT Microscope with 4K Camera Active Contract Opportunity Notice
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 9/18/2026
Follow Miltenyi Biotec for a gentleMACS(tm) Octo Dissociator with Heaters. Active Contract Opportunity
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 9/17/2026