Type I Ambulance
| Agency: | State Government of North Carolina |
|---|---|
| State: | North Carolina |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Mar 21, 2025 |
| Due Date: | Apr 17, 2025 |
| Solicitation No: | 121-121-02242025 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
| Solicitation Number: | 121-121-02242025 |
| Project Title: | Type I Ambulance |
| Description: | Type I ambulance with minimum 144” box length -2025 Ford F450 chassis with gas engine or functionally equivalent CAAS GVS v 3.0 unit compliant (Commission on Accreditation of Ambulance Services Ground Vehicle Standards) - 4 X 2 Drivetrain Regular cab with minimum heat, A/C, power locks, power windows, and radio - Back up camera system - Wheelbase minimum 158” to maximum 175” Interior box height (headroom) minimum 70” Exterior LED Emergency Lighting (minimum) • Two (2) Red Front Grill Lights • One (1) Red Left Front Fender Lights • One (1) Red Right Front Fender Lights • Six (6) Red and Two (2) White Front Box Scene Lights • Four (4) Red, Two (2) White and One (1) Amber/Yellow Rear Box Lights • Two (2) Red and Two (2) White Left Box Scene Lights • Two (2) Red and Two (2) White Right Box Scene Lights Interior Box Lights (minimum) • Four (4) LED Light Bars, Ceiling Mounted • Eight (8) LED Dome Lights, Ceiling Mounted • LED Lights Inside Cabinets Ambulance box must have the ability to operate with the chassis running (generator driven) -Integral generator (5.5 kw minimum) 110 volt to run ambulance box electrical and rear HVAC systems External hidden unlock switch - Minimum five-point harness in all box seats (four total) - Standard white/off white box with Rowan Cabarrus Community College Graphics (see example) Minimum 5 lb. mounted fire extinguisher - Dri-deck material in exterior compartments - Auto eject shore power 20/30 amp - Pigtail plug option - Oxygen compartment with M cylinder bracket/rollers Two D cylinder holders in oxygen compartment - Oxygen cylinder changing wrench dedicated to oxygen compartment - Connected oxygen regulator with hose in compartment for M cylinder Self-contained rear/box A/C unit with exhaust fan (capable of generator operation) - Rear/box heating - Backboard compartment with shelf - Door locks on all entry doors for cab and box Gas operated door holds for compartments - Siren speakers Whelen SA 315 -Siren Whelen C9 in console - Siren microphone - Siren Whelen C9 in console - Siren microphone - Single slot console switch panel in cab Siren mounted in console - Blank console slot with cover for future radio addition - USB / USB-C device connectors in cab and box - Armrests on seats in cab - 120 VAC connection in cab at console - Cab cupholders (2) Three box glove holder in cab - Backup warning system with speaker - Antitheft system - Stainless steel countertops in box - Stainless steel grab rails in box - Two duplex outlets in box - Safety netting in front corner area of box Mounted aluminum drug box, double locking, mounted in box - Minimum two oxygen outlets mounted in box with regulators (one on action wall, one near bench seating area -Thermostat control in box Mounted suction unit in action area of box - 120 VAC connection in box - Mounted door lock switches on action wall - Action area wall mounted large sharps container - Action wall lights and switches Single CPR seat with harness - Generator start/stop switch in box and in cab - Two seat positions on squad bench with harnesses - Squad bench cabinet - Handrail at head of squad bench Three box glove holder mounted on back way of box over squad bench - Mounted trash can with lid at head of squad bench or in step well - Two IV hangers on ceiling (one over stretcher, one over squad bench) Driver side stainless steel ceiling grab bar - Rear head knocker protections - Mounted clock - Stryker cot tower in box - Stryker floor track for power load Gen 2 Captain chair in box with integral child safety seat and harnesses - Cab running boards - D cylinder oxygen mount in box interior - Interior box cabinetry with Lexan doors |
| Opening Date: | 4/17/2025 12:30 AM |
| Posted Date: | 3/22/2025 |
| Status: | Open |
| Department: | ROWAN-CABARRUS COMMUNITY COLLEGE |
|
Solicitation Number
*
121-121-02242025
|
Department
ROWAN-CABARRUS COMMUNITY COLLEGE
|
Status Reason
Open
|
|
|
Opening Date
2025-04-17T00:30:00.0000000
|
Posted Date
*
2025-03-21T18:27:34.0000000Z
|
Commodity Code
Vehicle bodies and trailers
|
|
|
Mandatory Conference/Site Visit
—
—
|
Special Instructions
—
|
||
|
Description
Type I ambulance with minimum 144” box length -2025 Ford F450 chassis with gas engine or functionally equivalent CAAS GVS v 3.0 unit compliant (Commission on Accreditation of Ambulance Services Ground Vehicle Standards) - 4 X 2 Drivetrain Regular cab with minimum heat, A/C, power locks, power windows, and radio - Back up camera system - Wheelbase minimum 158” to maximum 175” Interior box height (headroom) minimum 70” Exterior LED Emergency Lighting (minimum) • Two (2) Red Front Grill Lights • One (1) Red Left Front Fender Lights • One (1) Red Right Front Fender Lights • Six (6) Red and Two (2) White Front Box Scene Lights • Four (4) Red, Two (2) White and One (1) Amber/Yellow Rear Box Lights • Two (2) Red and Two (2) White Left Box Scene Lights • Two (2) Red and Two (2) White Right Box Scene Lights Interior Box Lights (minimum) • Four (4) LED Light Bars, Ceiling Mounted • Eight (8) LED Dome Lights, Ceiling Mounted • LED Lights Inside Cabinets Ambulance box must have the ability to operate with the chassis running (generator driven) -Integral generator (5.5 kw minimum) 110 volt to run ambulance box electrical and rear HVAC systems External hidden unlock switch - Minimum five-point harness in all box seats (four total) - Standard white/off white box with Rowan Cabarrus Community College Graphics (see example) Minimum 5 lb. mounted fire extinguisher - Dri-deck material in exterior compartments - Auto eject shore power 20/30 amp - Pigtail plug option - Oxygen compartment with M cylinder bracket/rollers Two D cylinder holders in oxygen compartment - Oxygen cylinder changing wrench dedicated to oxygen compartment - Connected oxygen regulator with hose in compartment for M cylinder Self-contained rear/box A/C unit with exhaust fan (capable of generator operation) - Rear/box heating - Backboard compartment with shelf - Door locks on all entry doors for cab and box Gas operated door holds for compartments - Siren speakers Whelen SA 315 -Siren Whelen C9 in console - Siren microphone - Siren Whelen C9 in console - Siren microphone - Single slot console switch panel in cab Siren mounted in console - Blank console slot with cover for future radio addition - USB / USB-C device connectors in cab and box - Armrests on seats in cab - 120 VAC connection in cab at console - Cab cupholders (2) Three box glove holder in cab - Backup warning system with speaker - Antitheft system - Stainless steel countertops in box - Stainless steel grab rails in box - Two duplex outlets in box - Safety netting in front corner area of box Mounted aluminum drug box, double locking, mounted in box - Minimum two oxygen outlets mounted in box with regulators (one on action wall, one near bench seating area -Thermostat control in box Mounted suction unit in action area of box - 120 VAC connection in box - Mounted door lock switches on action wall - Action area wall mounted large sharps container - Action wall lights and switches Single CPR seat with harness - Generator start/stop switch in box and in cab - Two seat positions on squad bench with harnesses - Squad bench cabinet - Handrail at head of squad bench Three box glove holder mounted on back way of box over squad bench - Mounted trash can with lid at head of squad bench or in step well - Two IV hangers on ceiling (one over stretcher, one over squad bench) Driver side stainless steel ceiling grab bar - Rear head knocker protections - Mounted clock - Stryker cot tower in box - Stryker floor track for power load Gen 2 Captain chair in box with integral child safety seat and harnesses - Cab running boards - D cylinder oxygen mount in box interior - Interior box cabinetry with Lexan doors
|
|||
|
Attachments
|
|||
Get Government Bids Like This by Email
Receive daily bid alerts that match your keywords, business categories, and target regions.
See Also
Solicitation Number: Doc2312204550 Project Title: North Carolina Forest Service - Forest Protection (NCFS-FP)
State Government of North Carolina
Due by 10/01/2026
Solicitation Number: SCO-24-29039-02A Project Title: North Carolina Department of Transportation Description: Division 9
State Government of North Carolina
Due by 10/08/2026
DN01161 (WBS 2027CPT.14.01.10201, 2027CPT.14.01.20201, 50943.3.8) BO-2014E POC DN01161 (WBS 2027CPT.14.01.10201, 2027CPT.14.01.20201, 50943.3.8) BO-2014E
Division of Highways
Due by 9/22/2026
Solicitation Number: SCO-26-30900-01A Project Title: NC Department of Transportation Description: Hatteras Ferry Terminal
State Government of North Carolina
Due by 10/01/2026
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.