Town of High River
Background and Description of the Project:
The Town of High River is looking for a qualified contractor to complete an assessment of the current Mechanical Systems located at the Charles Clarke Health Clinic and provide prioritized recommendations and pricing.

Scope of the Services:
The Charles Clarke Health Clinic building is a two story with basement, LEED certified design and construction and the mechanical system is a conventional system for small buildings.

1.        Electrical Preheat Coil Installation Assessment
The installation of electrical preheat coils in the intake ducts servicing the Energy Recovery Ventilators (ERVs) is to be evaluated. The successful candidate shall engage a qualified electrical consultant to review the existing power distribution system and confirm the building’s electrical capacity to support the addition of preheat coils.

2.        Building Management System (BMS) Review
The building’s current Building Management System (BMS), enteliWEB, provides limited user access. The contractor shall assess the BMS to determine the feasibility of integrating an open-source or more accessible platform. This assessment must ensure the system allows full access to temperature controls and the ability to adjust setpoints as required.

3.        Elevate all the Mechanical Systems:
•        The system is heated with 2 Camus 300,000 Btuh boilers located in the penthouse mechanical room.
•         Located outdoors at grade is a 60-ton Carrier air cooled chiller filled glycol water solution. Glycol is piped to a glycol / water heat exchanger. Water is distributed to fan coils.
•        Hot water and chilled water are distributed to 4 pipe fan coils (Fan, cooling coil, heating coil and filter) on each building level.
•        Each building entrance has been provided with hot water fan coils.
o        4 Pipe Fan Coils
o        Basement - 4 Fan coils Size B @1, C@3
o        Main floor – 24 Fan coils Size A@3, B@8, C@5, D@3, E@5
o        Second floor – 27 Fan coils Size A@6, B@12, C@5, D@2, E@2
•        Ventilation to the fan coils is provided via 11 Mitsubishi Energy Recovery Ventilators
o        Basement – 2 Energy Recovery Ventilators
o        Main floor – 5 Energy Recovery Ventilators
o        Second floor – 5 Energy Recovery Ventilators
APC Reference # AB-2025-04372
Category Services
Posting Date • Time Jun 20, 2025 • 2:50 pm (MT)
Closing Date • Time Jul 10, 2025 • 4:00:00 pm (MT)
Region(s) of Delivery Alberta, High River
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Basic Information APC Reference # AB-2026-06256 Internal Reference # 27PAR8088 Title Crimson Lake

Government of Alberta

Due by 10/05/2026

Basic Information APC Reference # AB-2026-06286 Internal Reference # 27PAR8111 Title Pigeon Lake

Government of Alberta

Due by 10/05/2026

Basic Information APC Reference # AB-2026-05912 Internal Reference # 2026RFP0029 Title Parking lot

Government of Alberta

Due by 9/22/2026

Basic Information APC Reference # AB-2026-05839 Internal Reference # RFP-2026-0086 Title Downtown Utilities

Government of Alberta

Due by 9/29/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.