Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope

Agency: HEALTH AND HUMAN SERVICES, DEPARTMENT OF
State: Maryland
Type of Government: Federal
FSC Category:
  • 66 - Instruments and Laboratory Equipment
NAICS Category:
  • 334516 - Analytical Laboratory Instrument Manufacturing
Set Aside: Total Small Business Set-Aside (FAR 19.5)
Posted Date: Jul 15, 2026
Due Date: Jul 25, 2026
Solicitation No: 75N98026Q00794
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope
Active
Contract Opportunity
Notice ID
75N98026Q00794
Related Notice
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
NATIONAL INSTITUTES OF HEALTH
Office
NATIONAL INSTITUTES OF HEALTH OLAO
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
  • Original Published Date: Jul 15, 2026 09:25 am EDT
  • Original Date Offers Due: Jul 25, 2026 09:00 am EDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jul 26, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 334516 - Analytical Laboratory Instrument Manufacturing
  • Place of Performance:
    Bethesda , MD 20892
    USA
Description

Requirements:



Provides accurate dynamic control of temperature, humidity, CO2 and oxygen to maintain required cell culture conditions for live cell confocal and STED super-resolution imaging. The stage top incubator is required in order to perform live cell imaging with the unique resolution capabilities of our Leica Stellaris 5 STED microscope. It currently does not have a stage top incubator, and therefore, is unable to perform this type of imaging requested by NCI researchers.



Stage top incubator controller must have two feedback modes, chamber temperature or specimen temperature, while it also continuously monitors the room temperature to maintain specimen temperature within set point anywhere between 25 – 50 degrees Celsius. The built-in digital gas mixer controller accepts 100% CO2 from lab supply to regulate CO2 concentration at the sample, with a CO2 range of 5.0 to 20% with real-time sample feedback. In addition, humidity is actively controlled with an internal humidifier to sense sample chamber humidity. The electrically heated stage top incubator chamber must have magnets for easy interchange of specimen holders, including inserts for 35 mm coverglass dish, 50/60mm coverglass dish, chamber slide, coverglass chamber, and open frame insert for imaging multi-well chambers. A flexible heated collar that accommodates a range of objective lens diameters must also be included.



The components of the stage top incubator must include:




  • Tokai Hit STXG-GSI2X-SET Stage Top Incubator for Super Z galvo stage (inverted microscope stands)




  • Pure (100%CO2) gas use (110- 240V) for individual temperature settings to create optimum temperature and humidity conditions without difficulty for long term live cell imaging.




  • Setting temperature range from 25 to 50°C.




  • Dimensions of 112 x 87 mm compatible with Leica Super Z galvo stage on existing Leica Stellaris 5 STED microscope.




  • the lightest chamber (less than 140g) for Super Z Glavo stage




  • temperature controller with built-in digital gas mixer (CO2: 5.0 - 20.0%)




  • Objective heater




  • Magnetic Dish holder and fixing lid for 35mm, 50/60mm dish, chamber slide, slide glass and chamber slide use.




  • External Sensor, enable to autoclave repeatability for Sample Feedback regulation.




  • Tokai Hit original data logging, temp/CO2 program control, software compatible to use with LAS-X software




Attachments/Links
Contact Information
Contracting Office Address
  • 6011 EXECUTIVE BLVD., SUITE 503L
  • BETHESDA , MD 20892
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Jul 15, 2026 09:25 am EDTCombined Synopsis/Solicitation (Original)
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Follow Residual Gas Analyzer Active Contract Opportunity Notice ID 1333ND26QNB030584 Related Notice Department/Ind.

COMMERCE, DEPARTMENT OF

Due by 9/14/2026

Follow Miltenyi Biotec for a gentleMACS(tm) Octo Dissociator with Heaters. Active Contract Opportunity

HEALTH AND HUMAN SERVICES, DEPARTMENT OF

Due by 9/17/2026

Follow RAYMARINE OVERHAUL SERVICES Active Contract Opportunity Notice ID 70Z04026Q50258B00 Related Notice Department/Ind.

HOMELAND SECURITY, DEPARTMENT OF

Due by 9/14/2026

IFB 2027-15 ORGANIC OIL FOR BIOSOLIDS DUST SUPPRESSION SYSTEM A Pre-Bid Conference will

Howard County

Due by 9/23/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.