Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope
| Agency: | HEALTH AND HUMAN SERVICES, DEPARTMENT OF |
|---|---|
| State: | Maryland |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Jul 15, 2026 |
| Due Date: | Jul 25, 2026 |
| Solicitation No: | 75N98026Q00794 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Jul 15, 2026 09:25 am EDT
- Original Date Offers Due: Jul 25, 2026 09:00 am EDT
- Inactive Policy: Manual
- Original Inactive Date: Jul 26, 2026
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
-
NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
-
Place of Performance:
Bethesda , MD 20892USA
Requirements:
Provides accurate dynamic control of temperature, humidity, CO2 and oxygen to maintain required cell culture conditions for live cell confocal and STED super-resolution imaging. The stage top incubator is required in order to perform live cell imaging with the unique resolution capabilities of our Leica Stellaris 5 STED microscope. It currently does not have a stage top incubator, and therefore, is unable to perform this type of imaging requested by NCI researchers.
Stage top incubator controller must have two feedback modes, chamber temperature or specimen temperature, while it also continuously monitors the room temperature to maintain specimen temperature within set point anywhere between 25 – 50 degrees Celsius. The built-in digital gas mixer controller accepts 100% CO2 from lab supply to regulate CO2 concentration at the sample, with a CO2 range of 5.0 to 20% with real-time sample feedback. In addition, humidity is actively controlled with an internal humidifier to sense sample chamber humidity. The electrically heated stage top incubator chamber must have magnets for easy interchange of specimen holders, including inserts for 35 mm coverglass dish, 50/60mm coverglass dish, chamber slide, coverglass chamber, and open frame insert for imaging multi-well chambers. A flexible heated collar that accommodates a range of objective lens diameters must also be included.
The components of the stage top incubator must include:
- Tokai Hit STXG-GSI2X-SET Stage Top Incubator for Super Z galvo stage (inverted microscope stands)
- Pure (100%CO2) gas use (110- 240V) for individual temperature settings to create optimum temperature and humidity conditions without difficulty for long term live cell imaging.
- Setting temperature range from 25 to 50°C.
- Dimensions of 112 x 87 mm compatible with Leica Super Z galvo stage on existing Leica Stellaris 5 STED microscope.
- the lightest chamber (less than 140g) for Super Z Glavo stage
- temperature controller with built-in digital gas mixer (CO2: 5.0 - 20.0%)
- Objective heater
- Magnetic Dish holder and fixing lid for 35mm, 50/60mm dish, chamber slide, slide glass and chamber slide use.
- External Sensor, enable to autoclave repeatability for Sample Feedback regulation.
- Tokai Hit original data logging, temp/CO2 program control, software compatible to use with LAS-X software
- 6011 EXECUTIVE BLVD., SUITE 503L
- BETHESDA , MD 20892
- USA
- John Burton
- burtonjo@mail.nih.gov
- Jul 15, 2026 09:25 am EDTCombined Synopsis/Solicitation (Original)
See Also
Follow Residual Gas Analyzer Active Contract Opportunity Notice ID 1333ND26QNB030584 Related Notice Department/Ind.
COMMERCE, DEPARTMENT OF
Due by 9/14/2026
Follow Miltenyi Biotec for a gentleMACS(tm) Octo Dissociator with Heaters. Active Contract Opportunity
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 9/17/2026
Follow RAYMARINE OVERHAUL SERVICES Active Contract Opportunity Notice ID 70Z04026Q50258B00 Related Notice Department/Ind.
HOMELAND SECURITY, DEPARTMENT OF
Due by 9/14/2026
IFB 2027-15 ORGANIC OIL FOR BIOSOLIDS DUST SUPPRESSION SYSTEM A Pre-Bid Conference will
Howard County
Due by 9/23/2026