6515--636-24-2-4154-0058 - Supply - Slim HD Nasolaryngoscope - IC Need Date 5/31/2024

Agency: VETERANS AFFAIRS, DEPARTMENT OF
State: Iowa
Type of Government: Federal
FSC Category:
  • 65 - Medical, Dental, and Veterinary Equipment and Supplies
NAICS Category:
  • 339112 - Surgical and Medical Instrument Manufacturing
Posted Date: Apr 8, 2024
Due Date: Apr 17, 2024
Solicitation No: 36C26324Q0577
Bid Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Follow
6515--636-24-2-4154-0058 - Supply - Slim HD Nasolaryngoscope - IC Need Date 5/31/2024
Active
Contract Opportunity
Notice ID
36C26324Q0577
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 23 (36C263)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Sources Sought (Original)
  • All Dates/Times are: (UTC-05:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Original Published Date: Apr 08, 2024 09:03 am CDT
  • Original Response Date: Apr 17, 2024 10:00 am CDT
  • Inactive Policy: Manual
  • Original Inactive Date: Jul 25, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
  • NAICS Code:
    • 339112 - Surgical and Medical Instrument Manufacturing
  • Place of Performance:
    IOWA CITY VA HEALTH CARE SYSTEM 601 HIGHWAY 6 WEST IOWA CITY , 52246
Description
Sources Sought Brand Name Or Equal Nasolaryngoscope and Leak Tester for the Central Iowa VA Health Care System.

NAICS Code: 339112
Sources Sought Number: 36C26324Q0577
Notice Type: Sources Sought

This is a Request for Information (RFI) only; it is not a request for quotations or offers.

52.215-3 -- Request for Information or Solicitation for Planning Purposes (Oct 1997)
(a) The Government does not intend to award a contract on the basis of this solicitation or to otherwise pay for the information solicited except as an allowable cost under other contracts as provided in subsection 31.205-18, Bid and proposal costs, of the Federal Acquisition Regulation.
(b) Although proposal and offeror are used in this Request for Information, your response will be treated as information only. It shall not be used as a proposal.
(c) This solicitation is issued for the purpose of: conducting market research to identify potential sources for a potential procurement of Stress Test Equipment as indicated below.
See attached item specifications
This is a request for information and sources only, which may or may not lead to a future solicitation. This is not a request for proposal (RFP). The VA will not pay for any information received resulting from this sources sought notice. Information should be forwarded to the Contract Specialist. Any questions should be addressed to the Contract Specialist, in writing, at the email address provided. Because this is a request for information only, answers to questions will not be posted. If your organization has the capability to provide these supplies/services and is interested in this opportunity, please respond to Sara Hanson, Contract Specialist, Network 23 Contracting Office (NCO23), 4801 Veterans Drive St. Cloud, MN 56303 or via e-mail at Sara.Hanson@va.gov.
Please address the following in your responses:
Point of contact, UEI Number, complete mailing address, telephone number, and email address for your company/entity.
Socioeconomic status of your company/entity.
If applicable - GSA/FSS/ECAT/NASA SEWP contract number that these products or services are available under.
Product information/specifications of the systems that you can provide that meet the requirements of the DRAFT Specification-Statement of Work.
Proof of Authorized Distributorship for any product that is not manufactured by your company/entity. **Please note that the government will not accept any gray market items.
Manufacture Information of the product that your company/entity can provide to include: Manufacturer Name, Address, and UEI Number.
DISCLAIMER

This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
The deadline for this information is 10:00 AM Central Time on, Wednesday, April 17th, 2024

DESCRIPTION/SPECIFICATIONS for PENTAX Nasolaryngoscope and Hand-held Leak Tester
Requirement:

The contractor shall deliver, and provide any initial support associated with the purchase of qty 1 (one) PENTAX VNL11-J10, Slim HD or equal Nasolaryngoscope with the following minimum characteristics:

Endoscope must be flexible to be inserted transorally and transnasally
Solid state sensors arranged at the distal end of the endoscope to acquire images
Body mounted angulation control lever
Minimum field of view 85 degrees
Direction of no greater than 0 degrees
Depth of view minimum 3mm, maximum 50mm
Tip angulation shall span a minimum 130 degrees up and down
Minimum rigid distal width of 3.5 mm
Insertion tube width maximum 3.6 mm
Maximum insertion portion width 4.55 mm
Minimum insertion portion working length 300 mm
Maximum total length 500 mm
Compatible with Pentax EPK-i5010 light source/camera

The contractor shall deliver, and provide any initial support associated with the purchase of qty 1 (one) ZUTR0002P PENTAX Hand Held Leak Tester or equal with the following minimum characteristics:
Immediate air release capability to deflate endoscope for injury prevention
Minimum 250mm tubing
Compatibility with flexible scopes
Attachments/Links
Contact Information
Contracting Office Address
  • 316 Robert Street N Suite 506
  • Saint Paul , MN 55101
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 08, 2024 09:03 am CDTSources Sought (Original)

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Follow 6515--Bone Mill Active Contract Opportunity Notice ID 36C26324Q0587 Related Notice Department/Ind. Agency

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 5/01/2024

State of Iowa Bid Opportunities Bid Information Bid Number 240 Solicitation Tower removal

State Government of Iowa

Bid Due: 4/29/2024

Follow BPA for Theileria equi and Babesia caballi test kits at NVSL Ames,

Federal Agency

Bid Due: 1/18/2025

Follow BPA for Theileria equi and Babesia caballi test kits at NVSL Ames,

Federal Agency

Bid Due: 1/18/2025