Supple Science Roof Replacement-2027
| Agency: | State Government of Texas |
|---|---|
| State: | Texas |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Sep 14, 2026 |
| Due Date: | Oct 6, 2026 |
| Solicitation No: | 754-TXST-2027-CSP-515-PDC |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
754-TXST-2027-CSP-515-PDC
Posted
Allison England
(512) 245-5519
acq15@txstate.edu
10/6/2026
2:00 PM
754
21+ Days for Solicitation Notice
Dual CTCD/CTCM certification
9/14/2026
9/14/2026 8:18 am
91300-Construction Services, Heavy (Incl. Maintenance And Repair Services);
90900-Building Construction Services, New (Incl. Maintenance And Repair Services);
90921-Building Construction, Industrial (Warehouse, Etc.);
90922-Building Construction, Non;
90927-Building Construction, Educational;
91473-Roofing And Siding;
92544-General Construction: Management, Scheduling, Cost Estimation ;
91200-Construction Services, General (Incl. Maintenance And Repair Services);
90977-Special Construction: Observatory, Security, Special Rooms, Etc.;
90930-Building Construction (Not Otherwise Classified);
District 1,
District 2,
District 3,
District 4,
District 5,
District 6,
District 7,
District 8,
District 9,
District 10,
District 11,
District 12,
District 13,
District 14,
District 15,
District 16,
District 17,
District 18,
District 19,
District 20,
District 21,
District 22,
District 23,
District 24,
District 25
· Re-roofing of an existing science building. This project will consist of two phases. Phase I will be the completion of the main roof replacement, which directly impacts the building’s laboratory ventilation system. Contractor acknowledges that Texas State University laboratory classes will resume immediately following the winter break. Uninterrupted operation of the laboratory ventilation system is a strict requirement for student occupancy, academic instruction, and safety compliance. Phase II will consist of adjacent roofs which do not have a ventilation system. A Critical Path Method Schedule must be submitted detailing ventilation system coordination, weather contingencies, material procurement lead times, as well as clearly identifying all milestones that must be met in Phase I demonstrating how the winter break deadline will be successfully achieved.
See Also
STATE LET CONSTRUCTION CONTRACT, LUBBOCK CO, REHABILITATE EXISTING ROADWAY Follow Solicitation Solicitation ID:
State Government of Texas
Due by 12/02/2026
STATE LET CONSTRUCTION CONTRACT, ANDREWS CO, SAFETY LIGHTING AT INTERSECTION, ADD LEFT TURN
State Government of Texas
Due by 12/01/2026
STATE LET CONSTRUCTION CONTRACT, DE WITT CO, HAZARD ELIMINATION & SAFETY Follow Solicitation
State Government of Texas
Due by 12/02/2026
STATE LET CONSTRUCTION CONTRACT, GALVESTON CO, INSTALL NOISE BARRIER Follow Solicitation Solicitation ID:
State Government of Texas
Due by 12/02/2026