SP-300 Potentiostat, Potentiostat/galvanostat board and a standard cell cable with electrometer

Agency: ENERGY, DEPARTMENT OF
State: Tennessee
Type of Government: Federal
FSC Category:
  • 66 - Instruments and Laboratory Equipment
NAICS Category:
  • 334516 - Analytical Laboratory Instrument Manufacturing
Posted Date: Apr 29, 2025
Due Date: May 7, 2025
Solicitation No: RFQ371738
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
SP-300 Potentiostat, Potentiostat/galvanostat board and a standard cell cable with electrometer
Active
Contract Opportunity
Notice ID
RFQ371738
Related Notice
Department/Ind. Agency
ENERGY, DEPARTMENT OF
Sub-tier
ENERGY, DEPARTMENT OF
Office
ORNL UT-BATTELLE LLC-DOE CONTRACTOR
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Solicitation (Original)
  • Original Published Date: Apr 29, 2025 06:07 pm EDT
  • Original Date Offers Due: May 07, 2025 05:00 pm EDT
  • Inactive Policy: Manual
  • Original Inactive Date: May 10, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: 6630 - CHEMICAL ANALYSIS INSTRUMENTS
  • NAICS Code:
    • 334516 - Analytical Laboratory Instrument Manufacturing
  • Place of Performance:
    Oak Ridge , TN 37830
    USA
Description

SP-300 Potentiostat, Potentiostat/galvanostat board and a standard cell cable with electrometer



Request for the exact or domestic equivalent multi-channel, modular design potentiostat/galvanostat/EIS analyzer based on a portable chassis is required. Needs to be capable of USB and ethernet communication. Needs the following operational modes: floating, grounded, counter electrode to ground, working electrode to ground. EIS experiment functionality from 10 micro-Hz to 7 MHz. No separate analyzer should be required. Both sine and multi-sine techniques need to be available. Current and voltage should be possible to be measured simultaneously, with compliance voltage of +/- 12 Volt and reference voltage adjustable between -10 to +10 volts, with same range between working and reference electrodes. Resolution must be programmable from 300 micro-volts down to 1 micro-volts. Needs to apply and measure currents from 1 pico-amp to 500 milli-amps, a current control resolution of 0.004% and accuracies to 0.1% of FSR. Should be possible to be interfaced with boosters of 1,2,4 or 10 Amps on the same chassis. Multi-amp boosters should be possible to be paired for higher currents. Should be expandable to include a linear scan generator for true analog waveforms, up to 1 MV/s with data aquisition rates as fast as 1 micro-second. Requires an ultra-low current option to +/- 100 femto-amps on 1 pico-amp range with greater than 10^14 ohms input impedance. Should be capable of switching control modes in under 5 microseconds, without adverse spiking of the current in the connected cell. Requires an external input for control of potential or current via external analog input from separate device. Needs to have at least nine user-selectable bandwidths for full stability control on channels. Analog filters (50 kHz, 1 kHz, 5 Hz) as well as digital filtering in software. Needs to be able to acquire data at 20 micro-second frequency. Needs to be capable of 2-5 terminal measurements (for simultaneous WE-RE and RE-CE voltage and EIS techniques). Needs to be possible to self-calibrate. Software should be freely available and not require licenses or cloud computing. Needs to be able to interface with LabView virtual instrument software. needs to be able to load prior settings upon loading a previously-run data file. Should be able to group or synchronize channels for duplicate measurements. Software should be able to fit and simulate cyclic voltammetry curves. EIS analysis tools should include Mott-Schottky analysis. Should be able to run multiple sets of settings in a specific order utilizing a batch mode.


Attachments/Links
Contact Information
Contracting Office Address
  • Oak Ridge National Laboratory PO Box 2008
  • Oak Ridge , TN 37831
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Apr 29, 2025 06:07 pm EDTSolicitation (Original)
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Follow Keithley Instruments/Tektronix, Picoammeter/Voltage Source, and Calibration Active Contract Opportunity Notice ID RFQSS496408

ENERGY, DEPARTMENT OF

Due by 9/18/2026

Organic Polymer RFP Number: TC2027-03 Start Date: 08/19/2026 10:50 AM Close Date: 10/07/2026

Town of Collierville

Due by 10/07/2026

Follow Keithley Instruments/Tektronix, Picoammeter/Voltage Source, and Calibration Active Contract Opportunity Notice ID RFQSS496408

ENERGY, DEPARTMENT OF

Due by 9/18/2026

Follow 532 nm Single Channel Raman Instrument with SpectraSoft data acquisition software, and

ENERGY, DEPARTMENT OF

Due by 9/16/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.