Rubb Shelter Inspections

Agency: DEPT OF DEFENSE
State: Texas
Type of Government: Federal
FSC Category:
  • 54 - Prefabricated Structures and Scaffolding
NAICS Category:
  • 332311 - Prefabricated Metal Building and Component Manufacturing
Set Aside: No Set aside used
Posted Date: Feb 18, 2026
Due Date: Mar 5, 2026
Solicitation No: W50S77-26-Q-0001
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
Rubb Shelter Inspections
Active
Contract Opportunity
Notice ID
W50S77-26-Q-0001
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE ARMY
Major Command
NATIONAL GUARD BUREAU
Sub Command
JFHQ USPFO TX
Sub Command 2
USPFO TX PROCUREMENT
Office
W7N2 USPFO ACTIVITY TXANG 147
General Information
  • Contract Opportunity Type: Special Notice (Original)
  • Original Published Date: Feb 18, 2026 10:18 am CST
  • Original Response Date: Mar 05, 2026 02:00 pm CST
  • Inactive Policy: 15 days after response date
  • Original Inactive Date: Mar 20, 2026
  • Initiative:
    • None
Classification
  • Original Set Aside: No Set aside used
  • Product Service Code: 5410 - PREFABRICATED AND PORTABLE BUILDINGS
  • NAICS Code:
    • 332311 - Prefabricated Metal Building and Component Manufacturing
  • Place of Performance:
    Houston , TX 77034
    USA
Description

The 147th ATKW, Texas Air National Guard, intends to sole source inspection services of currently owned Aircraft Shelters. The repairs will consist of: The contractor shall provide all management, tools, supplies, equipment, and labor necessary to operate and maintain the required inspections. Structures are designed to require a minimal amount of maintenance over the life of the structures. The inspection should be performed bi-annually or after the structures are exposed to winds or snow loads close to the designed limit of the structure.





2.1. INSPECTION REQUIREMENTS





2.1.1. Check fabric tension around perimeter by pushing out fabric by hand from the inside of the structure at shoulder height. PVC should snap back sharply when released if correctly tensioned. Tighten as required. Removal of bird netting may be required.



2.1.2. Check tension rods along foundation for equal tension and lock nuts set. Tighten as required to equal tension in all rods in each bay area. Tighten any loose lock nuts as needed. Removal of bird netting may be required.



2.1.3. Check shackles connecting tension rods to foundation for loose pins or missing safety wire. Tighten pins as required and replace missing safety wire. Removal of bird netting may be required.



2.1.4. Check that the PVC covering is tensioned around the entire perimeter, Doors and vents. Reattach any loose PVC. Removal of bird netting may be required.



2.1.5. Check for any holes or rips in the PVC cover. Damage should be repaired according to the PVC repair procedure. Removal of bird netting may be required.



2.1.6 Check for areas of damaged galvanization or corrosion. Remove any corrosion and cover with a zinc rich coating. Removal of bird netting may be required.



2.1.7. Spot check a sample of various bolts for tightness. Tighten as required. A325 bolts are tightened according to the turn-of –the-nut method given in the A.I.S.C steel manual, 16th edition. This states that A325 bolts less than 4 diameters in length must be tightened an additional 1/3 turn past snug tight. Note A325 bolts in structure are less then 4 diameters long. All non A325 bolts are snug tight. Removal of bird netting may be required.



2.1.8. Check wind bracing cables for proper tensioning. They should be sag free. If cables are found to have sag, tighten a minimum of two full turns past the point where all the slack has been taken out of the cable. Removal of bird netting may be required.



2.1.9. Check node restraint cables for proper tension. Node restraint cables should be free of sag and snug tight. Removal of bird netting may be required.



2.1.10. STEELWORK INSPECTION - Check steelwork for missing or damagedcomponents. Replace or repair any damaged components found. Removal of bird netting may be required.



The 147th ATKW, Texas Air National Guard, intends to sole source the inspections as the current assets were purchased from Rubb Inc. and must be repaired, inspected, and maintained by the company to ensure the warranty for the shelters stays intact. Work by any other vendor would void any warranty for the shelters. FAR 13.106-1(b)(1) soliciting from one responsible source.


Attachments/Links
Contact Information
Contracting Office Address
  • KO FOR TXANG DO NOT DELETE 14667 SNEIDER ST BLDG 12
  • HOUSTON , TX 77034-5586
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Feb 18, 2026 10:18 am CSTSpecial Notice (Original)

Related Document

Apr 21, 2026[Combined Synopsis/Solicitation (Original)] Aircraft Shelter Inspections
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Follow Guard Booth - Austin Active Contract Opportunity Notice ID 2023H2-26-Q-00056 Related Notice

TREASURY, DEPARTMENT OF THE

Due by 9/18/2026

Bid Number: #046-026 Bid Title: McGarity 0.9 Million Gallon Ground Storage Tank Category:

City of Lucas

Due by 9/30/2026

Bid Number: BID #CB-2639 Bid Title: First Pressure Plane - 2.0 MG Elevated

City of Abilene

Due by 9/15/2026

Bid Information Type Request for Proposal Status Issued Number 2026-7-62 (Animal Shelter Storage

City of Allen

Due by 9/17/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.