Attachment Preview

CONSTRUCTION DOCUMENTS
PICKLEBALL COURTS
EAST TENNESSEE STATE UNIVERSITY
JOHNSON CITY, TENNESSEE
SBC PROJECT NO. 369/000-01-2021
CODE SYNOPSIS
GOVERNING CODES:
2021 International Building Code
2023 National Electric Code
2021 NFPA Life Safety Code (NFPA 101)
OCCUPANCY CLASSIFICATION:
N/A
BUILDING CONSTRUCTION:
N/A
PROJECT DESCRIPTION
WORK IS LIMITED TO THE FOLLOWING:
· NEW PICKLEBALL COURTS INCLUDING PLAYING SURFACE AND PERIMETER FINISHES
· NEW PICKLEBALL LIGHTING SYSTEM
· PROVISIONS FOR FUTURE COMMUNICATIONS CABLING
Architects
11/19/2025
11/19/2025
LEGEND
EXISTING CONTOUR MAJOR
EXISTING CONTOUR MINOR
EXISTING SPOT ELEVATION
PROPOSED CONTOUR MAJOR
PROPOSED CONTOUR MINOR
PROPOSED SPOT ELEVATION
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED CATCH BASIN
1675
1674
1674.6
1675
1674
1674.17
ST (E)
ST (E)
ST
ST
CB
1673.7
1673.7
1673.83
1673.6
1673.83
SITE GRADING NOTES
1. THIS SITE GRADING AND DRAINAGE PLAN SUPERIMPOSED ON SITE SURVEY
INFORMATION PROVIDED BY ALLEY & ASSOCIATES, PC AND OTHER SITE
INVESTIGATIONS.
1673.4
2. FOR PURPOSES OF ESTABLISHING SUB-GRADES, THE FOLLOWING FINISH
SURFACE THICKNESSES ARE APPLICABLE: PAVING 10" (4" ASPHALT AND 6" BASE
STONE), 8" FOR EXTERIOR CONCRETE SLAB (4" CONCRETE AND 4" BASE STONE).
3. PROVIDE POSITIVE DRAINAGE TO ALL LOW POINTS TO PREVENT PONDING OF
SURFACE RUN-OFF.
1673.7
15" RCP
INV.=1668.3'
1673.83
1674.0
4. PROVIDE A MINIMUM OF 6" TOPSOIL AND SEEDING OVER ALL DISTURBED YARD
AND/OR LANDSCAPE AREAS.
LOWER EXISTING CATCH BASIN
TO 1673.58 AND PROVIDE NEW
FOOT TRAFFIC RATED GRATE
(NEENAH FOUNDRY CATALOG
NO. 4808-A OR EQUAL) SEE
DETAILS SH. C 4.0
1673.8
1674.3
1674.4
CB
TOP=1674.0'
15" RCP
INV.=1668.4'
ST (E)
1673.58
S1T 6(E7) 3.83
1674.1
6" PVC
INV.=1668.3'
1674.08
1673.83
1673.83
1674.3
ST (E)
NEW CATCH BASIN (CB1)
TOP OF GRATE EL. 1673.83
INV. EL. 1671.83
NEW STORM PIPE - P1
30± LFT. 6" PVC
CONNECT TO EXITING CATCH
BASIN AT INV. EL. 1669.42
S = 8.03%
1673.8
1674.17
1673.9
NEW STORM PIPE - P2
16± LFT. 4" PVC
CONNECT TO EXISTING CATCH
BASIN AT INV. EL. 1669.83
1673.9
1673.83
T.G. 1673.83
INV. 1673.17
1674.0
±40 LFT. NEW 8" ACO S2OOK (OR
EQUIVALENT) TRENCH DRAIN
WITH MIN LOAD CLASS E
SLOTTED GRATE, S = 0.50%
BEGINNING INV. EL. 1673.17,
OUTLET INV. EL. 1673.07
1674.1
1674.17
1674.17
1673.9
1673.8
1674
ST (E)
ST (E)
ST (E)
ST (E) 1674.1S7T (E)
1674.3
PROVIDE SOLID COVER FOR EXISTING
CATCH BASIN AND PAVE OVER. LOWER
TOP OF CATCH BASIN AS NEEDED
1674.4
1674.17
1674.1
1674.17
ST
1674.1
T.G. 1673.83
INV. 1673.07
ST (E)
ST (E)
15" RCP
INV.=1669.0'
CB
TOP=1674.1'
1673.91
ST (E)
ST (E)
ST (E)
1674.4
8" PVC
INV.=1669.1'
T.G. 1673.83
INV. 1673.17
1673.83
ST (E)
1674.4
1674.2
ST (E)
ST (E1) 674.17 ST (E)
1674.08
1674.6
1674.17
NEW CATCH BASIN (CB2)
TOP OF GRATE EL. 1673.83
INV. EL. 1671.83
1674.0
1674.0
1673.83
1673.83
1674.0
NEW STORM PIPE - P3
24± LFT. 6" PVC
CONNECT TO EXITING CATCH
BASIN AT INV. EL. 1670.08
S = 7.29%
1674.0
8" PVC
INV.=1669.6'
ST (E)
ST (E)
1674.6
ST (E)
1673.83
1674.2
1674.2
CB
TOP=1674.2'
ST1(E6)73.83
1673.67
LOWER EXISTING CATCH BASIN
TO 1673.67 AND PROVIDE NEW
FOOT TRAFFIC RATED GRATE
(NEENAH FOUNDRY CATALOG NO.
4808-A OR EQUAL) SEE DETAILS
SH. C 4.0
1674.0
1674.5 1673.83
8" PVC
INV.=1669.7'
1674.17
1674.00
1674.1
1674.1
1674.08 1674.1 1674.08
1674.3
1674.33
1674.3
1674.00
1674.5
1674.3
1674.25
1674.3
1674.5
1674.6
1674.3
1674.5
1674.4
FFE = 1674.6
1674.4
1674.8
1674.6
1674.7
8" PVC
INV.=1670.2'
1674.5
CB
TOP=1674.1'
1674.6
8" PVC
INV.=1670.4'
ST (E)
1674.4
ST (E)
ST (E)
1674.3
ST (E)
1674.6
1674.1
1674.2
FACILITY
SYSTEMS
CONSULTANTS, LLC
713 S. Central Street
Suite 101
Knoxville, Tennessee 37902
ph: (865) 246-0164
fx: (865) 246-1084
This drawing and the design shown are the
property of Facility System Consultants,
LLC, and are not to be reproduced, copied,
published or used in whole or in part
without written consent. They are to be
used only for the project and site identified
and shall be returned upon request.
Revisions:
GRADING AND DRAINAGE PLAN
SCALE: 1/8" = 1'-0"
TRUENORTH
Job No:
Date:
Designed by:
Drawn by:
ETS508
1111//1179//22002255
BWJ
JDG
Sheet Title:
GRADING AND
DRAINAGE PLAN
Scale:
AS NOTED
SHEET
C 3.0
EXISTING STORM SEWER CATCH BASIN GRATE DETAIL
SCALE: N.T.S.
ENSURE GRATE
OPENINGS ARE
SAFE FOR
PLAYGROUND USE
(1) INTEGRATED DUCTILE IRON
FRAME & GRATE TO MATCH BASIN
O.D. GRATE TO BE STAMPED
"DUMP NO WASTE" & "DRAINS TO
STREAM"
(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERS
AVAILABLE: 4" - 30" FOR CORRUGATED HDPE
(ADS N-12/HANCOR DUAL WALL, ADS/HANCOR
SINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),
PVC DWV (EX: SCH 40), PVC C900/C905,
CORRUGATED & RIBBED PVC
(5) ADAPTER
ANGLES
VARIABLE 0° -
360°
ACCORDING TO
PLANS
WATERTIGHT JOINT
(CORRUGATED HDPE SHOWN)
(3) VARIABLE SUMP DEPTH
ACCORDING TO PLANS
(6" MIN. ON 8" - 24", 10" MIN. ON 30"
BASED ON MANUFACTURING REQ.)
4" MIN ON 8" - 24"
6" MIN ON 30"
1 - 8" - 30" STANDARD GRATES SHALL BE DUCTILE IRON PER ASTM A536
GRADE 70-50-05.
2 - 12" - 30" FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE
70-50-05.
8" & 10" STANDARD GRATES FIT DIRECTLY ONTO DRAIN BASINS WITH
THE
USE OF A PVC BODY TOP. SEE DRAWING NO. 7001-110-045.
3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN
DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO
SHIPPING
RESTRICTIONS. SEE DRAWING NO. 7001-110-065.
4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO
ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL),
N-12 HP, & PVC SEWER (4" - 24").
5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO
DETERMINE
MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.
6 - 12" - 30" STANDARD GRATES SHALL MEET H-20 LOAD RATING.
7 - 8" & 10" STANDARD GRATES ARE RATED FOR LIGHT DUTY
APPLICATIONS
ONLY; NO CONCRETE COLLAR NEEDED FOR LIGHT DUTY RATING.
THE BACKFILL MATERIAL SHALL BE CRUSHED
STONE OR OTHER
GRANULAR MATERIAL MEETING THE
REQUIREMENTS OF CLASS I,
CLASS II, OR CLASS III MATERIAL AS DEFINED IN
ASTM D2321.
BEDDING & BACKFILL FOR SURFACE DRAINAGE
INLETS SHALL BE
PLACED & COMPACTED UNIFORMLY IN
ACCORDANCE WITH ASTM D2321.
THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH
DRAWN BY EBC MATERIAL
NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT
OR POSSESSION OF THIS PRINT DOES NOT CONFER, DATE
1-23-06
TRANSFER, OR LICENSE THE USE OF THE DESIGN OR
TECHNICAL INFORMATION SHOWN HEREIN
REVISED BY NMH PROJECT NO./NAME
REPRODUCTION OF THIS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF ANY
DATE
ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS
03-11-16
IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSION FROM NYLOPLAST.
©2011 NYLOPLAST DWG SIZE
A SCALE 1:40 SHEET 1 OF 1
TITLE
3130 VERONA AVE
BUFORD, GA 30518
PHN (770) 932-2443
® FAX (770) 932-2490
www.nyloplast-us.com
DRAIN BASIN WITH STANDARD GRATE
QUICK SPEC INSTALLATION DETAIL
DWG NO.
7001-110-144
REV H
CB1 & CB2 NYLOPLAST DRAIN BASIN WITH 18" x 18" FRAME AND GRATE (OR EQUIVALENT)
SCALE: N.T.S.
FACILITY
SYSTEMS
CONSULTANTS, LLC
713 S. Central Street
Suite 101
Knoxville, Tennessee 37902
ph: (865) 246-0164
fx: (865) 246-1084
This drawing and the design shown are the
property of Facility System Consultants,
LLC, and are not to be reproduced, copied,
published or used in whole or in part
without written consent. They are to be
used only for the project and site identified
and shall be returned upon request.
Revisions:
TRENCH DRAIN INSTALLATION DETAIL
SCALE: N.T.S.
Job No:
Date:
Designed by:
Drawn by:
ETS508
1111//1179/2025
BWJ
JDG
Sheet Title:
GRADING AND
DRAINAGE DETAILS
Scale:
AS NOTED
SHEET
C 4.0
This page summarizes the opportunity, including an overview and a preview of the attached documents.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Form Details (Abstract): RFQ 361785 Status Active Document PDF File Abstract Negotiation Number

City of Memphis

Bid Due: 6/24/2026

SBC Project Number Agency Project Title Attachments 529/028-01-2026 DGS Tennessee Residence Update TN

State Government of Tennessee

Bid Due: 6/09/2026