ADDENDUM NUMBER 04
DATE:
May 19, 2026
PROJECT:
CHEAHA STATE PARK FIRE STATION
PROJECT NUMBER: ASPD PROJECT #: 2026-005-16FS
OWNER:
State Parks Division of the ADCNR
64 N. Union Street, Suite 538
Montgomery, AL 36104
ENGINEER:
Three Notch Group, Inc.
224 Broad Street, Suite 201
Gadsden, Alabama 35901
TO:
Prospective Bidders
This Addendum forms a part of the Contract Documents and modifies the Bidding Documents dated April
17, 2026.
Contractors shall acknowledge receipt of this Addendum in the space provided in the Proposal Form.
Failure to do so may disqualify future Bidders.
This Addendum consists of Three (3) pages including attachments.
CHANGES TO THE PROJECT MANUAL
1. N/A
CHANGES TO THE CONSTRUCTION PLANS
1. Sheet C-302A – UTILITY PLAN
a. Replace with the attached revised drawing.
b. Soils & soil bore locations updated according to Health Dept. comments
CLARIFICATIONS
1. Pertaining to the casework – equivalent manufacturers/ products, adhering to all requirements of
the plans/specifications, will be entertained as an alternative upon submittal request during
construction.
2. The cutoff for RFI’s was pushed, one week, to Friday, May 15th.
CONTRACTOR QUESTIONS / RFI’s
1. There is no spec for the elastomeric coating. Is this required since it is shown at an interior wall? If
so, please provide a spec. The elastomeric coating is not required. Paint to match the interior paint
of the CMU walls.
2. There is no spec for the rigid insulation. Please provide. Refer to Specifications, Section “07 4800
Rainscreen Attachment System” 2.02 MINERAL FIBER INSULATION:
Addendum No. 04
2100
SEE HIGH INTENSITY
SOILS MAP 2095
REMOVE EXISTING TREES IN
CONFLICT W/ DESIGN, TYP.
280 LF (5 ROWS OF 56') OF 36" WIDE
INFILTRATOR CHAMBERS, QUICK4
LOW PROFILE (OR EQUAL),
16" MAX TRENCH DEPTH PER SOIL
SCIENTIST REPORT, SEE PROFILES
2080
2075
SOIL CLASSIFIER BORE
LOCATIONS, TYP
2095
BORE HOLE SB7
SB7
ROW 4
ROW 2
ROW 5 ROW 3
ROW 1
TALLAPOOSA RIVER ELECTRIC COOP
OVERHEAD POWER & EASEMENT
DISPOSAL AREA TO BE FLAGGED,
2
STAKED, OR OTHERWISE FENCED OFF
AND PROTECTED DURING THE ENTIRE
56'
DURATION OF CONSTRUCTION
56'
BORE HOLE SB6
2090
SB6 BM# 1
SB8
2090
BORE HOLE SB8 S
4
S
5',
MIN.
52"x40" METAL GRATE
D
INLET EL: 2085.65'
S
INV: 2082.07'
STM
150 L.F. SPLIT
RAIL FENCE
15S"TMCMP
STM
STM
2085
BORE HOLE SB5
REDF AREA
SB5
PRESSURE MANIFOLD,
SEE DETAIL
INV: 2080.98'
4" SDR-35 PVC GRAVITY
2085
LINES @ 2% MIN.,
TYP OF 5
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
OE
SANITARY SEWER ALTERNATING D20U80PLEX GRINDER PUMP,
GOULDS AGS1012 GRINDER PUMP
1HP, 230V (±10%), SINGLE PHASE
~203 L.F. SANITARY SEWER
FORCE MAIN,
1.5" SCH 40 PVC,
SEE DETAILS THIS SHEET
OE
OE
TOP = 2093.50' (~6" ABOVE SURROUNDING GRADE)
4" INV. IN ≈ 2090.00'
STATION BOTTOM ≈ 2086.50'
2 1000 GALLON SEPTIC TANK W/ INTEGRAL PUMP
3 CHAMBER, MITCHELL CONCRETE SPECIALTIES
M1000IPC (OR EQUAL) W/ EFFLUENT FILTER
BLDG
(POLYLOK PL-68 OR EQUAL)
C
W
WATER LINES SHALL BE:
1.
~ INSTALLED
LINES SHALL
BWEITIHNSATMALINLIEMDUWMITHHORAIZMOINNITMAULMSVEEPRATRIACTAILONSEOPFA5R20AF7TE0IEOTNFORFO1M8"SAANNDITATHREY
SEWER, WHEN CROSSING GRAVITY
WATER LINE SHALL BE CASED WITH
SEWERS OR FORCE MAINS, WATER
10 LINEAR FEET OF STEEL PIPE, SEE
UTILITY CROSSING DETAIL
2" WATER SERVICE SHALL BE:
~ CL 200 PVC
2.
~ MARKED WITH NO. 10 COPPER LOCATOR WIRE
~ 36" MINIMUM COVER
NOTE: SEE TYPICAL TRENCH DETAIL FOR ADDITIONAL INFORMATION
CONTRACTOR SHALL FURNISH ALL BENDS AND FITTINGS AS REQUIRED FOR WATER SERVICE INSTALLATION.
2075
~ ALL BENDS AND FITTINGS SHALL BE DUCTILE IRON (D.I.) MECHANICAL JOINT (M.J.)
3.
~ ALL VALVES, BENDS, FITTINGS, AND TAPPING SLEEVES AND VALVES SHALL HAVE CONCRETE THRUST BLOCKS, SEE DETAIL
~ ALL FITTINGS SHALL BE THE SAME SIZE AND PRESSURE RATING AS THE PIPE.
~ ALL VALVES SHALL BE DUCTILE IRON (D.I.)
2065
OE
OE
C
SANITARY SEWER SERVICE
W/ TWO-WAY CLEANOUT
SEE MECH FOR
CONTINUATION
OE
CONTRACTOR SHALL FURNISH ALL BENDS, FITTINGS, AND CLEANOUTS AS REQUIRED FOR SEWER LATERAL INSTALLATION.
1.
~ PIPE LENGTHS AND SLOPES CAN BE FOUND ON PLANS
NOTE: SEE TYPICAL CLEANOUT DETAILS FOR ADDITIONAL INFORMATION
1.5" SANITARY SEWER FORCEMAIN SHALL BE:
~ SCH 40 PVC
2.
~ MARKED WITH NO. 10 COPPER LOCATOR WIRE
~ 36" MINIMUM COVER
NOTE: SEE TYPICAL TRENCH DETAIL FOR ADDITIONAL INFORMATION
OE
OE
OE
OE
OE
ALTERNATING DUPLEX
CONTROL PANEL W/ ALARM
BY PUMP MANUFACTURER
MOUNTED TO BUILDING,
SUBMITTAL REQUIRED
BREAKROOM
171
133 SF
UTILITY
169
38 SF
STOAGE
170
38 SF
13'-4"
PARK STAFF
162
186 SF
This document and its contents are property of Three Notch Group, Inc. and may not be distributed, reused, or modified without permission.
TIE TO EXISTING 3" PVC WATER
SERVICE (APPROXIMATE
LOCATION - FIELD VERIFY)
2095
~52 L.F. WATER SERVICE LINE,
2" CL 200 PVC, SEE DETAILS
THIS SHEET
PT
20
0
20
SCALE IN FEET
PROFESSIONAL SEAL:
05/19/2026
COA: ECA105
ADDRESS:
515 LOCUST ST.
GADSDEN, AL 35901
PH: (256) 543-9431
SHEET NO:
C-302A