REPAIR WAKABA CDC

Agency: DEPT OF DEFENSE
State: Federal
Type of Government: Federal
FSC Category:
  • Z - Maintenance, Repair or Alteration of Real Property
NAICS Category:
  • 236220 - Commercial and Institutional Building Construction
Set Aside: No Set aside used
Posted Date: Jun 17, 2025
Due Date: Jul 1, 2025
Solicitation No: FA527025R0038
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page

Description

Follow
REPAIR WAKABA CDC
Active
Contract Opportunity
Notice ID
FA527025R0038
Related Notice
Department/Ind. Agency
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Major Command
PACIFIC AIR FORCES
Office
FA5270 18 CONS PK
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Presolicitation (Original)
  • Original Published Date: Jun 17, 2025 12:50 pm JST
  • Original Response Date: Jul 01, 2025 12:00 pm JST
  • Inactive Policy: Manual
  • Original Inactive Date: Jul 01, 2025
  • Initiative:
    • None
Classification
  • Original Set Aside: No Set aside used
  • Product Service Code: Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
  • NAICS Code:
    • 236220 - Commercial and Institutional Building Construction
  • Place of Performance:
    Kadena AFB , JP-47 96368
    JPN
Description

This project shall accomplish a design-build repair of:

 Work for the addition shall be completed in Phase I, B131, includes recoat roof with elastomeric

roofing, replace rusted exterior door fixtures and frames, replace ceiling tiles, replace all float glass

with tempered glass, repaint wall and countertop, install FRP wainscot, replace corroded flush

valves and faucets, clean HVAC ductworks, replace diffuser, and replace rusted light fixtures.

Work area has been tested for Asbestos-Containing Materials (ACM)/Lead-Based Paint (LBP) and

only found asbestos in the wall mortar, so no ACM/LBP abatement is needed but workers shall

wear appropriate protective equipment if work involves disturbing the mortar.

 Repair the Wakaba Child Development Center (CDC), B132 shall be completed in Phase II and

may require additional phasing. Work for the main building, B132, includes demolish front

entrance metal grating door mat, replace rusted exterior door fixtures and frames, replace all float

glass with tempered glass, repaint wall and countertop, install Fiberglass Reinforced Panel (FRP)

wainscot, replace Children Activity Room (CAR) adult size toilets with children size toilets,

replace corroded flush valves and faucets, repair kitchen grease duct to correct Fire Safety

Deficiency (FSD), clean HVAC ductworks, replace diffuser, and replace all HVAC components

that are near the end of their service life such as the condenser, chiller, boiler, and water circulating

pumps.

Work for the project is described in more detail in Section 8 of this Statement of Work (SOW). Sustainable

principles, to include life cycle cost- effective practices shall be integrated into the design, development, and

construction of the project(s) in accordance with the latest version of UFC 1-200-02, High Performance and

Sustainable Building Requirements.

Construction activities may commence after the approval of the Environmental Protection Plan (EPP) and AF

Form 103 (work clearance). The Contractor shall coordinate on-site safety requirements through the 718th

Civil Engineer Squadron (718 CES).


Attachments/Links
Contact Information
Contracting Office Address
  • (ADMIN ONLY NO REQTN) UNIT 5199
  • APO , AP 96368-5199
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • Jun 17, 2025 12:50 pm JSTPresolicitation (Original)

Related Document

Jun 16, 2025[Sources Sought (Original)] REPAIR WAKABA CDC
Jul 15, 2025[Solicitation (Original)] REPAIR WAKABA CDC
Aug 5, 2025[Solicitation (Updated)] REPAIR WAKABA CDC
Get Government Bids Like This by Email Receive daily bid alerts that match your keywords, business categories, and target regions.

See Also

Follow Z1DA--Replace Cast Iron Fittings 676-23-009 Active Contract Opportunity Notice ID 36C25226B0037 Related

VETERANS AFFAIRS, DEPARTMENT OF

Due by 10/14/2026

Follow ZION-EAST ENTRANCE STATION REHAB Active Contract Opportunity Notice ID 140P6026Q0063 Related Notice

INTERIOR, DEPARTMENT OF THE

Due by 9/15/2026

Follow NNSY DD4 DUCT INSULATION REPLACEMENT Active Contract Opportunity Notice ID N4008526R0254 Related

DEPT OF DEFENSE

Due by 9/21/2026

Follow MT-BOWDOIN NWR-HQ OFFICE FLOORS Active Contract Opportunity Notice ID 140FGA26Q0074 Related Notice

INTERIOR, DEPARTMENT OF THE

Due by 9/23/2026

* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.