Repair oil leak on 45611
| Agency: | HOMELAND SECURITY, DEPARTMENT OF |
|---|---|
| State: | Texas |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Feb 18, 2026 |
| Due Date: | Feb 25, 2026 |
| Solicitation No: | 52000PR260003454 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
- Original Published Date: Feb 18, 2026 11:31 am EST
- Original Date Offers Due: Feb 25, 2026 09:00 am EST
- Inactive Policy: 15 days after date offers due
- Original Inactive Date: Mar 12, 2026
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: J020 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIP AND MARINE EQUIPMENT
-
NAICS Code:
- 336611 - Ship Building and Repairing
-
Place of Performance:
Galveston , TX 77550USA
SOW
STBD MTU S60 ENGINE REPAIR ON RB-M 45611.
ENGINE S/N: 06R1021268
Page 1 of 2
REQUIREMENTS: This requirement is for the excessive oil leak repair of the 45611 S60 Engine at Station Port Aransas. All maintenance, repair, and overhaul services performed on the MTU S60 engine must be executed exclusively by MTU-certified technicians.
This policy is mandatory to ensure the highest standards of quality, performance, and reliability as intended by the manufacturer.
To uphold warranty conditions and ensure engine longevity, the following terms are non-negotiable:
- No Subcontracting: The engagement of any third-party or subcontracting entities for any portion of the work is strictly prohibited. The authorized MTU service provider is responsible for all work performed by its direct, certified staff.
- Certified Technicians Only: All technicians must have completed extensive, official MTU training and be certified to perform work on the specified engine series.
- Genuine Parts: Only genuine MTU Original Equipment Manufacturer (OEM) parts and consumables are to be used for any service or repair.
The use of non-genuine parts or service by unauthorized providers may void the engine's warranty.
Failure to comply with these requirements may result in the voiding of the engine's warranty and could compromise the operational integrity and safety of the equipment.
DESCRIPTION:
A certified MTU diesel technician experienced in the overhaul and repair of the USCG MTU S60 engines used on the 45’ RB-M shall provide travel and labor and consumable parts to perform the repair of the Starboard engines of hull# 45611.
The use of non MTU/Detroit Dealer technician for this service will have a negative impact on the Coast Guard due to the special tooling and technician certification required to perform this service. Only a MTU technician/distributor can provide the correct parts and repairs needed to ensure the engine is sealed properly IAW MTU specifications and will function properly and accurately to new factory specifications. Using only a certified MTU/Detroit Dealer Distributor ensures and validates the engine will be functional and reliable when it is installed in the CG 45' RB-M vessel.
The technician shall provide the required credentials to access the US Government facility at:
USCG IPF Galveston, TX
3000 Fort Point Rd
Galveston, TX 77550
POC: MK1 William Constable
Station EPO
(361) 443-9048 Cell Phone
SCOPE OF WORK:
- Stbd S60 Engine S/N: 06R1021268
1.1 S60 MTU engine technician shall provide labor, and consumable parts to repair the following Stbd engine discrepancies:
-
-
- Replace front gear case housing seal and camshaft thrust bearing seal.
- Torque all fasteners IAW MTU specifications
-
1.1.3 Replace oil pan gasket and fasteners.
1.1.4 Re-time and tune up engine IAW MTU specifications for USCG S60 engine.
1.1.5 Return engine to a fully operational status.
- 2401 HAWKINS PT RD. BLDG 31 MS 26
- BALTIMORE , MD 21226
- USA
- Joshua Richardson
- joshua.c.richardson2@uscg.mil
- Feb 18, 2026 11:31 am ESTCombined Synopsis/Solicitation (Original)
See Also
STATE LET MAINTENANCE CONTRACT, TARRANT CO, METAL BEAM GUARD FENCE REPAIR Follow Solicitation
State Government of Texas
Due by 10/07/2026
STATE LET MAINTENANCE CONTRACT, LAMPASAS CO, BRIDGE PREVENTATIVE MAINTENANCE Follow Solicitation Solicitation ID:
State Government of Texas
Due by 10/07/2026
STATE LET MAINTENANCE CONTRACT, HARRIS CO, FULL DEPTH CONCRETE REPAIR Follow Solicitation Solicitation
State Government of Texas
Due by 10/07/2026
Project: Siemens Contactor Repair Ref. #: DFW20671 Department: Energy Transportation Asset Mgmt Type:
Dallas/Fort Worth International Airport
Due by 9/16/2026