| Agency: | State Government of Hawaii |
|---|---|
| State: | Hawaii |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Jun 18, 2026 |
| Due Date: | Jul 20, 2026 |
| Solicitation No: | Q26003433 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
General Information
Direct all questions regarding this Solicitation, and any questions or Issues relating to the accessibility
of this Solicitation (Including the appendices and exhibits to this Document, and any other document related
to this Solicitation), to:
Wong, Jason.
| Commodity Code | Description |
| 332913 | Backflow preventers, plumbing, manufacturing |
| 488119 | Airports, civil, operation and maintenance |
Direct all questions regarding this Solicitation, and any questions or Issues relating to the accessibility
of this Solicitation (Including the appendices and exhibits to this Document, and any other document related
to this Solicitation), to:
Wong, Jason.
STATE OF HAWAII
DEPARTMENT OF TRANSPORTATION
AIRPORTS DIVISION / MAUI DISTRICT
MOLOKAI AIRPORT
REPAIR BACKFLOW PERVENTERS
CM2646-33
SCOPE OF WORK - The Contractor shall furnish all equipment, labor and materials to
troubleshoot and repair leaking backflow preventer at the Molokai Airport (MKK). Depending
on the results of the troubleshooting task, some, or none, of the other work items below will
be directed by the Airport District Manager.
a. Troubleshoot Leak: Contractor shall test, troubleshoot and diagnosis the cause of a
water leak in the 6-inch Reduced Pressure Backflow Preventer assembly at the
Aircraft Rescue Fire Fighting (ARFF) facility at MKK. Work shall be done on a Lump
Sum basis, in the proposal schedule. Work must be performed by a licensed
technician certified to test and maintain backflow preventers.
b. Repairs to Backflow Preventer: Contractor shall procure all parts and perform work to
repair 6-inch backflow preventer. Work shall be done on a force account basis, under
the Allowance bid item in the proposal schedule.
c. Replacement of 6-Inch Backflow Preventer and Gate Valve Assembly: Contractor
shall furnish all equipment, labor and materials to replace 6-Inch Backflow Preventer
assembly (assembly includes backflow preventer unit and two each 6-inch gate
valves between 90 degree elbow fittings) with a new DWS approved assembly unit, if
needed. Work shall be done to ensure the whole assembly unit is fully functional for
use for intended purpose.
d. Miscellaneous Repairs: Contractor shall perform miscellaneous testing and repairs
for unforeseen conditions at ARFF facility, and other backflow preventers at MKK, as
directed by the Airport District Manager on a force account basis. The Airport
Manager shall negotiate recommended repairs through the Allowance item in the
Proposal Schedule. Use of this Allowance shall be at the sole discretion of the Airport
Manager.
WORKING HOURS - 7:00 am to 3:00 pm, Monday through Friday, except for State Holidays.
All work shall be coordinated with the Airport Maintenance Supervisor.
Work is subject to Chapter 104 requirements. Prevailing wages and certified payroll
shall apply to this project.
All bids over $25,000.00 shall be required to provide a performance and payment bond
for award.
To arrange a site visit, please contact Antone Kalilikane at Ph. 808-567-9660.
Contractor shall provide a Certificate of Insurance for the project with coverage
amounts of $1 million dollars for general liability and $1 million automotive liability
with the State of Hawaii named as additionally insured.
AIRPORT SECURITY - Due to location of jobsite within Airport Operation Area (AOA) the
Contractor shall be responsible to obtain AOA ID badges for employees working on this
project. Cost to obtain AOA ID badge is approx. $60 per employee. Use of company vehicles
within AOA requires special $1,000,000 General Liability Commercial Insurance and AOA
vehicle sticker. Cost for AOA ID badges and AOA vehicle stickers are considered incidental
to the project.
CONTRACTOR QUALIFICATIONS
a. Contractor shall possess a State of Hawaii Specialty Contractor's License "C-37"
at the time of bid.
b. Contractor must be certified to perform testing and maintenance on backflow
preventer equipment and present a current certificate when the diagnostic and
repair work is being done.
COMPLETION OF WORK - All work shall be complete within 30 calendar days from the
issuance of the Purchase Order.
LIQUIDATED DAMAGES - Liquidated damages of $100.00 per calendar day shall be assess
for each day the project is delayed beyond the 30-day completion time.
PAYMENT - Invoices including any deductions for liquidated damages shall be submitted for
payment to the Business Services Supervisor at the address below:
State Department of
Transportation
Airports Division - Maui District
1 Kahului Airport Road, Unit 5
Kahului, Hawaii 96732-2327
WORK AREA - See attached Location Plan
With Free Trial, you can:
You will have a full access to bids, website, and receive daily bid report via email and web.
Solicitation #: 2026-1290 Title: KAHALU`U BOOSTERS A & B REPAIR Category: Construction Jurisdiction:
State Government of Hawaii
Bid Due: 9/03/2026
Day Date Time Area ADD/ / AMD GCA# Project 08/21/26 11:00am Guam 1
General Contractors Association
Bid Due: 8/21/2026
Follow Repair Roll-up Doors, JBPHH, Hawaii Air National Guard Active Contract Opportunity Notice
DEPT OF DEFENSE
Bid Due: 8/18/2026
Solicitation #: IFB 27-0012 Title: PRICE TERM AGREEMENT FOR ICE MACHINE PREVENTATIVE MAINTENANCE,
State Government of Hawaii
Bid Due: 8/19/2026