PW - 103497-2 Marine Creek Sanitary Sewer Parallel Interceptor M-279 & M-245B - Part II
| Agency: | City of Fort Worth |
|---|---|
| State: | Texas |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Sep 24, 2026 |
| Due Date: | Oct 29, 2026 |
| Solicitation No: | 26-0332 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
Project Description: Unit I: Sanitary Sewer Improvements
1. Installation of approximately 3,960 LF of 48-inch thru 72-inch sanitary sewer pipe by open cut with all associated appurtenances and required testing.
2. Installation of approximately 570 LF of 72-inch sanitary sewer pipe with 90-inch steel casing pipe by other than open cut (Open-Shield Pipejacking) with all associated appurtenances and required testing.
3. Installation of approximately 2,430 LF of 48-inch thru 72-inch sanitary sewer pipe by other than open cut within 60-inch thru 90-icnh steel casing pipe or 60-inch thru 100-inch tunnel liner plate with all associated appurtenances and required testing.
4. Installation of approximately 1,470 LF of 6-inch thru 18-inch sanitary sewer pipe by open cut with all associated appurtenances and required testing.
5. Bypass Pumping of existing sanitary sewer lines.
6. Construction of (2) sanitary sewer siphon structures
7. Construction of (2) sanitary sewer junction structures
Unit II: Water Improvements
1. Installation of approximately 2,200 LF of 36-inch water pipe by open cut with all associated appurtenances and required testing.
2. Installation of approximately 280 LF of 36-inch water pipe with 48-inch steel casing pipe or 50-inch tunnel liner plate by other than open cut with all associated appurtenances and required testing.
3. Installation of approximately 425 LF of 24-inch AWWA C200 Steel water pipe on existing bridge with all associated appurtenances and required testing.
4. Installation of approximately 4,330 LF of 6-inch thru 12-inch water pipe by open cut with all associated appurtenances and required testing.
5. Cathodic Protection of 24-inch thru 36-inch water pipe with all associated appurtenances and required testing.
See Also
LOCAL LET MAINTENANCE CONTRACT, TERRELL CO, PICNIC AREA MAINTENANCE Follow Solicitation Solicitation ID:
State Government of Texas
Due by 12/08/2026
Project: Pavement Rehabilitation District 1 Ref. #: RFB 2026-061 Department: Infrastructure Services Type:
City of Waco
Due by 12/08/2026
RFQ769-27-1028CS Sycamore Hall Stewardship Renovation Status: Open Solicitation Prebid Meeting Date: Wednesday, October
University of North Texas System
Due by 11/20/2026
Bid Number: IFB # 2027-600-02 Bid Title: UTILITY SYSTEM SUPPLIES Category: Request for
City of Jacksonville
Due by 11/24/2026