2026 PS02 – Collegeville Pump Station Improvements

Agency: Jefferson County
State: Alabama
Type of Government: State & Local
NAICS Category:
  • 237110 - Water and Sewer Line and Related Structures Construction
Posted Date: Oct 30, 2025
Due Date: Dec 19, 2025
Solicitation No: 9912791
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Post Date 10/30/2025
Quest Number 9912791
Category Code Electrical and Controls,Fittings and Valves,Pumps or Pump stations,Sanitary Sewer (Gravity)
Bid/Request Name 2026 PS02 – Collegeville Pump Station Improvements
Bid Closing Date 12/19/2025 11:00 AM CST
City Birmingham
County Jefferson
State AL
Owner Jefferson County, AL - Environmental Serv (Hazen)
Soliciator Hazen and Sawyer - Birmingham
Posting Type Construction Project
Location Details
City: Birmingham
County: Jefferson
State/Province: AL
Project Details
Closing Date: Fri, 12/19/2025 11:00 AM CST
Project Bid Received By & Opening Information: Jefferson County Environmental Services Department
Est. Value: $ 10,000,000.00
Pre-Qualification:
Yes
Pre-Bid Meeting Info: The Contractor is hereby advised that a Pre-Bid Conference will be held via a virtual video conference on Wednesday, December 3rd, 2025, at 10:00 A.M. This Pre-Bid Conference is MANDATORY for all contractors planning to submit a Bid Proposal on this project. The conference call will be held using Microsoft Teams and can be accessed using a direct invitation link sent via email (request this link from Tad Powell, Hazen and Sawyer, at email tpowell@hazenandsawyer.com). If you are unable to join the call due to technical difficulties, call Tad Powell (Hazen and Sawyer) at 205-957-4151 or Brian Rohling (Jefferson County) at 205-521-7512 for assistance.
Project Description
Project Category Code: Pumps or Pump stations, Fittings and Valves, Electrical and Controls, Sanitary Sewer (Gravity)
Description: Collegeville Pump Station (PS050): •        Demolition of existing pump station, including but not limited to, pumps, piping, building structure, and electrical components; •        Installation of 8-foot by 6-foot precast concrete bypass structure with cast-in-place concrete base, stainless steel weir assembly, and monolithic liner; •        Improvements and conversion of existing wet well and dry pit into auxiliary overflow storage structure; •        Installation of approximately 60 linear feet of 24-inch new sanitary sewer pipe; •        Installation of two 60-inch diameter precast concrete sewer manholes; •        Installation of one 12-foot by 12-foot precast concrete wet well with monolithic liner; •        Installation of four submersible pumps with all controls, piping, valves, fittings, and appurtenances; •        Installation of one 16-foot by 8-foot precast concrete valve vault; •        Installation of one 60-inch diameter precast concrete manhole with magnetic flow meter; •        Installation of one elevated generator building with exterior platform and natural-gas-powered backup generator and electrical equipment and pump station electrical components; •        Removal, relocation, and installation of electrical riser poles, transformers, and overhead lines; •        New Spire Gas service and relocations; •        Site improvements, including gates, fencing, concrete paving, concrete pump station pad, lighting, and restoration work.
Primary Contact Information
Owner Details
Owner Name: Jefferson County, AL - Environmental Serv (Hazen)
Address: 716 Richard Arrington Jr. Blvd North, Suite A 300, Birmingham, AL - 35203
Phone: 205-521-7512
Contact: Brian Rohling
Email: rohlingb@jccal.org
Solicitor Details
Solicitor Name: Hazen and Sawyer - Birmingham
Design Discipline: Soliciting agent
Address: Two Chase Corporate Drive, Suite 170, Birmingham, AL - 35244
Phone: 205-547-5960
Contact: Tad Powell
Email: tpowell@hazenandsawyer.com
Project Document Information
Document Information: The Contractor is hereby advised that the Engineer will be available to the project site on Thursday, December 4th, 2025, at 9:00 A.M. Additional details will be provided at the Pre-Bid Conference. Questions concerning meaning or intent of Bidding Documents shall be submitted to Tad Powell, PE, Senior Associate, Hazen and Sawyer, at email tpowell@hazenandsawyer.com no later than 5:00 P.M. local time on Thursday, December 11th, 2025. All questions must be in writing on Bidder’s company’s letterhead.
Quest eBidDoc™ Delivery Info: Download delivery fee is $22.00 , file size is 203 MB . Preview Download
Fee for bidding online is $42.00
You must be a plan holder to enter an Online Bid. Do you want to continue?
Yes No
PLACE HOLDER
OK
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Sourcing Project Number: SRC0000034096 Solicitation Label: Replacement Air Compressor at Decatur NGA Status:

State Government of Alabama

Bid Due: 6/15/2026

Follow Sources Sought B1502 Renovation Active Contract Opportunity Notice ID PANNGB-26-P-0000033323 Related Notice

DEPT OF DEFENSE

Bid Due: 6/05/2026

Agency Agency Link Agency Number Status Category Sub Category 2026-163-07 Description: Coffee Shop

Alabama Department of Finance

Bid Due: 6/04/2026

Follow Z1DA--679-24-102 B18 Laundry Renovations & Additions Active Contract Opportunity Notice ID 36C24726R0083

VETERANS AFFAIRS, DEPARTMENT OF

Bid Due: 6/05/2026