PHASE 4 – RECONNECT PROJECT – GENERATORS AND BATTERIES for COs and CABINETS
| Agency: | Orangeburg County |
|---|---|
| State: | South Carolina |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Aug 24, 2026 |
| Due Date: | Sep 14, 2026 |
| Solicitation No: | FY27-0914 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
| Bid Number: |
FY27-0914
|
| Bid Title: |
PHASE 4 – RECONNECT PROJECT – GENERATORS AND BATTERIES for COs and CABINETS
|
| Category: | Orangeburg County Bid Opportunities |
| Status: | Open |
|
Attachment Preview
12V FRONT TERMINAL SERIES
Battery
Range Summary
As the increased need for digital information
continues, both telecom and cable suppliers
need to keep up. They have responded by
adding additional equipment in central offices
and data centers - adding heat to an already
fragile environment. Cooling costs continue
to rise and are escalated by the density of
communication equipment. These extra costs
have led to the development of a new battery
Product Characteristics
designed to operate at higher temperatures,
allowing end users to raise the AC set points
* Wide operating temperature range -40 degreesF
and reduce their maintenance costs.
(-40 degreesC) to 149 degreesF (65 degreesC)
* Front terminal design
The next generation of front terminal batteries
* UL 94 V-0 Plastic
from EnerSys(R). The PowerSafe SBS XL series
* Designed for operation in accordance with
comes from a respected lineage, the industry
Telcordia(R) GR-4228 Level III, NEBS(TM) GR-63
leading, PowerSafe SBS Thin Plate Pure Lead
* Designed to comply with the requirements
(TPPL) battery. PowerSafe SBS XL takes the
of the international IEC 60896-21/22
SBS to the next level. The PowerSafe SBS XL
standard
battery is designed to provide 10 years of life
* 20 year design life @ 77 degreesF (20 degreesC)
at 95 degreesF (35 degreesC) in back up applications at high
* 10 year design life @ 95 degreesF (35 degreesC)
operating temperatures. The value of this
innovative new line is a true cost savings to the
operator for both cooling and maintenance.
Visit us at www.enersys.com
| Nominal Ah | Nominal Dimensions | Electrolyte 1.33SG Weight (per bloc) | Pure Acid (HSO) 2 4 | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PowerSafe Battery Type | Nominal Voltage (V) | 8hr. Rate 1.75Vpc @ 77 degreesF* | 8hr. Rate 1.75Vpc @ 95 degreesF* | 10hr. Rate 1.75Vpc @68 degreesF* | 10hr. Rate 1.75Vpc @ 95 degreesF* | Lenght | Width | Height | Typical Weight | Short Circuit Current (Amps) | Internal Resistance Milli-0hms | Lead Weight (per bloc) | Volume (per bloc) | ||||||||
| in | mm | in | mm | in | mm | lbs | kg | lbs | kg | lbs | kg | gal | L |
Construction
* Positive Plates - utilize TPPL Installation & Operation Standards
technology * Designed for operation at high * Approved as non-hazardous cargo for
* Negative Plates - provide perfect temperatures in float applications ground, sea and air transportation in
balance with the positive plate to * Wide operating temperature: -40 degreesF accordance with US DOT Regulation
ensure optimum recombination (-40 degreesC) to 149 degreesF (65 degreesC) 49 and ICAO & IATA Packing
efficiency instruction 806
* Classic industry container footprint
* Separators - superior quality * Designed to be compliant with
* Designed for use in cabinets or on
microporous glass mat separators with international standard IEC 60896/21
stands, close to the point of use;
high absorption and stability and 22
separate battery room is not required
* Containers and Lids - UL94 V-0 rated * Designed to be compliant with
* Blocs should be installed on their base
flame retardant Polycarbonate (PC) Telcordia(R) GR-4228
or horizontally on their longest sides
- ABS material, highly resistant to * The management systems governing
elevated temperatures, shocks and * Up to two year shelf life due to low the manufacture of this product are
vibrations rate of self-discharge ISO 9001:2008, ISO 14001:2004 and
* Electrolyte - high grade dilute sulphuric * Low maintenance; no water addition OHSAS 18001 certified.
acid absorbed into separator material required
* Terminals - high integrity leak resistant
terminal seal design
* Terminals - 2 X M6 Male
* Self-regulating Pressure Relief Valves -
prevent ingress of atmospheric oxygen
* Flame Arrestors - built into each bloc
for increased operational safety
General Specifications
Nominal Ah Nominal Dimensions Electrolyte Pure Acid (HSO)
2 4
1.33SG Weight
Lead Weight Volume
Lenght Width Height Typical Weight (per bloc)
Short (per bloc) (per bloc)
Nominal 8hr. Rate 8hr. Rate 10hr. Rate 10hr. Rate Internal
PowerSafe Circuit
Voltage 1.75Vpc 1.75Vpc 1.75Vpc 1.75Vpc Resistance
Battery Type Current
(V) @ 77 degreesF* @ 95 degreesF* @68 degreesF* @ 95 degreesF* in mm in mm in mm lbs kg Milli-0hms lbs kg lbs kg gal L
(Amps)
SBSXL 80F-FT 12 78.4 80 80 82.5 16.4 417 4.1 105 10.1 256 58.8 26.7 1700 7.7 11.46 5.2 41.4 18.8 0.32 1.23
SBSXL 150F-FT 12 147.2 150.4 150 155 22.1 561 4.9 125 11.1 283 111.7 50.7 2950 4.4 21.82 9.9 78.2 35.5 0.62 2.35
SBSXL 170F-FT 12 167.2 170.4 170 175 22.1 561 4.9 125 12.4 316 127.8 58 4100 3 25.57 11.6 89.5 40.6 0.73 2.75
Outline Drawings
W
W
L
L
H
H
SBS XL 80F SBS XL 150F-FT and SBS XL 170F-FT
| PowerSafe Battery Type | Standby Time (Minutes) | Standby Time (Hours) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Vpc | 30 | 35 | 40 | 45 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 20 |
| PowerSafe Battery Type | Standby Time (Minutes) | Standby Time (Hours) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Vpc | 30 | 35 | 40 | 45 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 20 |
Discharge Currents (Amperes) 77 degreesF (25 degreesC)
PowerSafe Standby Time (Minutes) Standby Time (Hours)
Battery Type Vpc 30 35 40 45 1 2 3 4 5 6 7 8 9 10 20
1.75 89.98 80.79 73.46 67.45 54.48 31.88 22.88 17.89 14.77 12.63 11.05 9.83 8.87 8.08 4.33
SBSXL 80F-FT 1.80 82.56 74.51 68.06 62.68 51.05 30.45 22.15 17.52 14.56 12.5 10.97 9.79 8.852 8.084 4.33
1.85 71.25 54.73 59.39 54.97 45.6 27.81 20.44 16.28 13.59 11.7 10.29 9.2 8.33 7.6 4.13
1.75 168.1 150.9 137.3 126.1 101.9 59.68 42.85 33.52 27.69 23.66 20.71 18.43 16.63 15.16 7.98
SBSXL 150F-FT 1.80 154.3 139.2 127.2 117.2 95.49 57 41.49 32.82 27.29 23.42 20.56 18.35 16.6 15.16 7.98
1.85 133.2 121 111.1 102.8 85.31 52.07 38.29 30.51 25.46 21.93 19.29 17.25 15.62 14.24 7.59
1.75 192.9 173.1 157.3 144.3 116.4 67.98 48.73 38.08 31.43 26.85 23.49 20.9 18.85 17.18 9.21
SBSXL 170F-FT 1.80 176.9 159.5 145.6 134.1 109.1 64.92 47.18 37.29 30.98 26.58 23.32 20.81 18.81 17.18 9.21
1.85 152.5 138.5 127 117.5 97.37 59.28 43.53 34.65 28.9 24.88 21.88 19.55 17.7 16.16 8.76
Discharge Currents (Amperes) 95 degreesF (35 degreesC)
PowerSafe Standby Time (Minutes) Standby Time (Hours)
Battery Type Vpc 30 35 40 45 1 2 3 4 5 6 7 8 9 10 20
1.75 94.2 84.4 76.6 70.2 56.5 32.7 23.5 18.3 15.1 12.9 11.3 10 9.05 8.25 4.43
SBSXL 80F-FT 1.80 86 77.5 70.7 65.1 52.7 31.2 22.7 17.9 14.8 12.7 11.2 9.99 9.03 8.25 4.43
1.85 73.7 67 61.4 56.7 46.9 28.5 20.9 16.6 13.8 11.9 10.5 9.38 8.5 7.76 4.22
1.75 176 158 143 131 106 61.3 44 34.3 28.3 24.1 21.1 18.8 17 15.5 8.16
SBSXL 150F-FT 1.80 161 145 132 122 98.6 58.5 42.5 33.5 27.8 23.9 21 18.7 16.9 15.5 8.16
1.85 138 125 115 106 87.7 53.3 39.2 31.1 25.9 22.4 19.7 17.6 15.9 14.5 7.76
1.75 202 181 164 150 121 69.8 50 38.9 32.1 27.4 24 21.3 19.2 17.5 9.41
SBSXL 170F-FT 1.80 184 166 151 139 113 66.6 48.4 38.1 31.6 27.1 23.8 21.2 19.2 17.5 9.41
1.85 158 143 131 121 100 60.7 44.5 35.3 29.5 25.4 22.3 19.9 18.1 16.5 8.98
EnerSys World Headquarters EnerSys EMEA EnerSys Asia Contact:
2366 Bernville Road EH Europe GmbH 152 Beach Road
Reading, PA 19605, USA Baarerstrasse 18 Gateway East Building #11-08
Tel: +1-610-208-1991 6300 Zug Singapore 189721
+1-800-538-3627 Switzerland Tel: +65 6416 4800
(C) 2024 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates except ISO, Telcordia and NEBS which are not the property of EnerSys.
Subject to revisions without prior notice. E.&O.E.
4210-LXSBS-SP-SR-NE-REMA
:oN
noitacilbuP
See Also
Ad Title: PHASE 4 - RECONNECT PROJECT - GENERATORS AND BATTERIES for COs
State of South Carolina - State Fiscal Accountability Authority(SFAA)
Due by 9/14/2026
Project: Lifecycle Replacement of Existing 60 kW Generator Ref. #: RFP 2026-0029 Department:
Savannah Hilton Head International Airport
Due by 9/30/2026
Project Name: Greenville Branch Phase 2 - Bridge and Park Components Agency/Owner: City
State of South Carolina - State Fiscal Accountability Authority(SFAA)
Due by 10/15/2026