Periodic Bid for Sanitary Sewer Bore Items-2026 Project No. 71-26-SP33

MANDATORY Pre-Bid Meeting will be held on Wednesday, April 22, 2026, at 10:00 a.m. CST and the Bid Opening will be held on Wednesday, April 29, 2026, at 10:00 a.m. CST.

Both meetings will be held at City Hall, in Training Room 624, located at 305 Fountain Circle, Huntsville, AL 35801.

Attached Files
File Description Download
Quantities-Attachment A Download
Specifications Download
Advertisement Download
Bid Contacts
Name Job Title
Chase Marshall Project Engineer
Mary Ridgeway Procurement & Contracts Coordinator

Attachment Preview

ITEM NO. DESCRIPTION BID QTY BID UNIT BID UNIT PRICE BID AMOUNT
MOBILIZATION
1 Project Mobilization A (will be paid on projects that have a cost greater than $5,000.00) 1 EA $0.00
2 Project Mobilization B (will be paid on projects that have a cost greater than $5,000.00, but less than $10,000.00) 10 EA $0.00
3 Project Mobilization C (will be paid on projects that have a cost greater than $10,000.00, but less than $25,000.00) 20 EA $0.00
4 Project Mobilization D (will be paid on projects that have a cost greater than $25,000.00, but less than $50,000.00) 30 EA $0.00
5 Project Mobilization E (will be paid on projects that have a cost greater than $50,000.00, but less than $75,000.00) 2 EA $0.00
6 Project Mobilization F (will be paid on projects that have a cost greater than $75,000.00, but less than $100,000.00) 8 EA $0.00

ATTACHMENT "A" 4/10/2026
Periodic Bid for Sanitary Sewer Bore Items-2026
Project No. 71-26-SP33
UNIT BID SHEET
ITEM NO. DESCRIPTION BID QTY BID UNIT BID UNIT PRICE BID AMOUNT
MOBILIZATION
Project Mobilization A (will be paid on projects that have
1 1 EA $0.00
a cost greater than $5,000.00)
Project Mobilization B (will be paid on projects that have
2 a cost greater than $5,000.00, but less than $10,000.00) 10 EA $0.00
Project Mobilization C (will be paid on projects that have
3 a cost greater than $10,000.00, but less than $25,000.00) 20 EA $0.00
Project Mobilization D (will be paid on projects that have
4 a cost greater than $25,000.00, but less than $50,000.00) 30 EA $0.00
Project Mobilization E (will be paid on projects that have
5 a cost greater than $50,000.00, but less than $75,000.00) 2 EA $0.00
Project Mobilization F (will be paid on projects that have
6 a cost greater than $75,000.00, but less than $100,000.00) 8 EA $0.00
Project Mobilization G (will be paid on projects that have
7 a cost greater than $100,000.00, but less than 4 EA $0.00
$250,000.00)
Page 1 of 10

JACK AND BORE INSTALLATION
Jack and Bore Installation of Steel Casing Pipe per linear foot installed in place. Includes compensation for furnishing steel casing pipe; excavation of bore pits; temporary shoring; sheeting and bracing; dewatering; traffic control and maintenance; backfilling; and all other required appurtenances for a complete installation. The installation of the carrier pipe inside the encasement pipe shall be by others and is not included.
16" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.25", SOIL installation
8 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C 200 LF $0.00
9 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF
16" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.25", ROCK installation
10 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
11 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and (Appendix B, C) 600 LF
18" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.25", SOIL installation
12 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
13

JACK AND BORE INSTALLATION
Jack and Bore Installation of Steel Casing Pipe per linear foot installed
in place. Includes compensation for furnishing steel casing pipe;
excavation of bore pits; temporary shoring; sheeting and bracing;
dewatering; traffic control and maintenance; backfilling; and all other
required appurtenances for a complete installation. The installation of
the carrier pipe inside the encasement pipe shall be by others and is not
included.
16" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.25", SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
8 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C
b. 10' - 16' depth (City of Huntsville Design and
9 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
16" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.25", ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
10 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
11 Acceptance Manual for Sanitary Sewers, Sec. 4 and 600 LF $0.00
(Appendix B, C)
18" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.25", SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
12 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
13 Acceptance Manual for Sanitary Sewers, Sec. 4 and 600 LF $0.00
Appendix B, C)
Page 2 of 10

18" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.25", ROCK installation
14 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix, B, C) 200 LF $0.00
15 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF
24" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.25", SOIL installation
16 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
17 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec 4 and Appendix B, C) 600 LF
24" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.25", ROCK installation
18 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
19 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF
30" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.312", SOIL installation
20 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
21

18" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.25", ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
14 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix, B, C)
b. 10' - 16' depth (City of Huntsville Design and
15 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
24" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.25", SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
16 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
17 Acceptance Manual for Sanitary Sewers, Sec 4 and 600 LF $0.00
Appendix B, C)
24" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.25", ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
18 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
19 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
30" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.312", SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
20 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
21 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
Page 3 of 10

30" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.312", ROCK installation
22 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
23 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 600 LF
36" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.312", SOIL installation
24 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
25 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF
36" Diameter Steel Encasement Pipe, ASTM A139, Minimum Wall 0.312", ROCK installation
26 a. 3'-10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
27 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF
48" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.312", ROCK installation
28 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 100 LF $0.00
29

30" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.312", ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
22 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
23 Acceptance Manual for Sanitary Sewers, Sec. 4 and 600 LF $0.00
Appendix B, C)
36" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.312", SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
24 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
25 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
36" Diameter Steel Encasement Pipe, ASTM A139,
Minimum Wall 0.312", ROCK installation
26 a. 3'-10' depth (City of Huntsville Design and Acceptance 200 LF $0.00
Manual for Sanitary Sewers, Sec. 4 and Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
27 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
48" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.312", ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
28 Acceptance Manual for Sanitary Sewers, Sec. 4 and 100 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
29 Acceptance Manual for Sanitary Sewers, Sec. 4 and 100 LF $0.00
Appendix B, C)
Page 4 of 10

48" Diameter Steel Encasement Pipe, ASTM A139, Minimum wall 0.312", SOIL installation
30 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 100 LF $0.00
31 b. 10' - 16' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 100 LF $0.00
Installation of Carrier Pipe Inside Encasement Pipe including required spacers. Pipe & Gaskets furnished by others.
32 a. 4" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
33 b. 6" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
34 c. 8" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
35 d. 10" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
36 e. 12" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
37 f. 16" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00

48" Diameter Steel Encasement Pipe, ASTM A139,
Minimum wall 0.312", SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
30 Acceptance Manual for Sanitary Sewers, Sec. 4 and 100 LF $0.00
Appendix B, C)
b. 10' - 16' depth (City of Huntsville Design and
31 Acceptance Manual for Sanitary Sewers, Sec. 4 and 100 LF $0.00
Appendix B, C)
Installation of Carrier Pipe Inside Encasement Pipe
including required spacers. Pipe & Gaskets furnished by
others.
a. 4" Ductile Iron Pipe (City of Huntsville Design and
32 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
b. 6" Ductile Iron Pipe (City of Huntsville Design and
33 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
c. 8" Ductile Iron Pipe (City of Huntsville Design and
34 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
d. 10" Ductile Iron Pipe (City of Huntsville Design and
35 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
e. 12" Ductile Iron Pipe (City of Huntsville Design and
36 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
f. 16" Ductile Iron Pipe (City of Huntsville Design and
37 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
Page 5 of 10

$0.00
39 h. 24" Ductile Iron Pipe (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
40 New Pipe Connection to Existing Manhole, including laterals (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 3, 4 and Appendix B, C) 20 EA $0.00
DIRECTIONAL DRILL INSTALLATION
Direction Drill Installation of HDPE Pipe per linear foot installed in place. Includes compensation for excavation of bore pits; temporary shoring, sheeting and bracing; dewatering; traffic control and maintenance; backfilling; and all other required appurtenances for a complete installation. The purchase of the HDPE Pipe, necessary Fittings, and the fusing of the Pipe shall be by others and is not included.
2" Diameter HDPE Pipe, SOIL installation
41 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
2" Diameter HDPE Pipe, ROCK installation
42 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00

g. 18" Ductile Iron Pipe (City of Huntsville Design and
38 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
h. 24" Ductile Iron Pipe (City of Huntsville Design and
39 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
New Pipe Connection to Existing Manhole, including
40 20 EA $0.00
laterals (City of Huntsville Design and Acceptance
Manual for Sanitary Sewers, Sec. 3, 4 and Appendix B, C)
DIRECTIONAL DRILL INSTALLATION
Direction Drill Installation of HDPE Pipe per linear foot installed in place.
Includes compensation for excavation of bore pits; temporary shoring,
sheeting and bracing; dewatering; traffic control and maintenance;
backfilling; and all other required appurtenances for a complete
installation. The purchase of the HDPE Pipe, necessary Fittings, and
the fusing of the Pipe shall be by others and is not included.
2" Diameter HDPE Pipe, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
41 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
2" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
42 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
Page 6 of 10

4" Diameter HDPE, SOIL installation
43 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
4" Diameter HDPE Pipe, ROCK installation
44 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
6" Diameter HDPE, SOIL installation
45 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 1,000 LF $0.00
6" Diameter HDPE Pipe, ROCK installation
46 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 400 LF $0.00
8" Diameter HDPE, SOIL installation
47 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
8" Diameter HDPE Pipe, ROCK installation
48 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00

4" Diameter HDPE, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
43 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
4" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
44 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
6" Diameter HDPE, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
45 Acceptance Manual for Sanitary Sewers, Sec. 4 and 1,000 LF $0.00
Appendix B, C)
6" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
46 Acceptance Manual for Sanitary Sewers, Sec. 4 and 400 LF $0.00
Appendix B, C)
8" Diameter HDPE, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
47 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
8" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
48 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
Page 7 of 10

10" Diameter HDPE, SOIL installation
49 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
10" Diameter HDPE Pipe, ROCK installation
50 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
12" Diameter HDPE, SOIL installation
51 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
12" Diameter HDPE Pipe, ROCK installation
52 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
16" Diameter HDPE, SOIL installation
53 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00
16" Diameter HDPE Pipe, ROCK installation
54 a. 3' - 10' depth (City of Huntsville Design and Acceptance Manual for Sanitary Sewers, Sec. 4 and Appendix B, C) 200 LF $0.00

10" Diameter HDPE, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
49 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
10" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
50 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
12" Diameter HDPE, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
51 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
12" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
52 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
16" Diameter HDPE, SOIL installation
a. 3' - 10' depth (City of Huntsville Design and
53 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
16" Diameter HDPE Pipe, ROCK installation
a. 3' - 10' depth (City of Huntsville Design and
54 Acceptance Manual for Sanitary Sewers, Sec. 4 and 200 LF $0.00
Appendix B, C)
Page 8 of 10

This page summarizes the opportunity, including an overview and a preview of the attached documents.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Sourcing Project Number: SRC0000034615 Solicitation Label: Various Handyman Repairs in Showers at Talladega

State Government of Alabama

Bid Due: 8/17/2026

Follow Horizontal Construction MATOC Active Contract Opportunity Notice ID W9127826RA088 Related Notice Department/Ind.

DEPT OF DEFENSE

Bid Due: 9/11/2026

Sourcing Project Number: SRC0000034696 Solicitation Label: ITB_Replace Rotten Windows at Gadsden GSB Status:

State Government of Alabama

Bid Due: 8/11/2026

Sourcing Project Number: SRC0000034755 Solicitation Label: ENGR-Kilby-Metal for Freezer roof Status: Open for

State Government of Alabama

Bid Due: 7/28/2026