6515--Oximeters Nellcorâ„¢ Portable SpO2 Patient Monitoring System, Model PM10
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jul 8, 2025 |
| Due Date: | Jul 15, 2025 |
| Solicitation No: | 36C24125Q0631 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Jul 08, 2025 11:30 am EDT
- Original Response Date: Jul 15, 2025 04:30 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Aug 14, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
- 339112 - Surgical and Medical Instrument Manufacturing
-
Place of Performance:
VAMC Bedford Bedford , 01730USA
Medtronic/Coviden Nellcor Portable SpO2 Patient Monitoring System, Model PM10N, brand name or equal, domestic and non-domestic.
The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide the following items:
ITEM NUMBER
DESCRIPTION
QUANTITY
UNIT OF MEASURE
0001
PM10N PORTABLE SpO2 PATIENT MONITOR
34
EA
0002
PMAC10N-G PORTABLE SpO2 COVER GREEN
34
EA
0003
DS100A-1 DURASENSOR ADULT FINGER CLIP
1
BX
0004
DURA-Y SENSOR
34
EA
0005
DURA-Y SENSOR EAR
34
EA All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum:
(1) Company name and address point of contact with phone number and SAM UEI.
(2) Documentation relating to performance capability, current point of contact, and phone number).
(3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc.
(4) Place of manufacture
(5) Any other pertinent company documentation prior to submission of offers to a solicitation.
Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation.
This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via manases.cabrera@va.gov
RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. FDA Clearance
Must have pre-market approval
Stand-Alone / Modular
Must be a handheld device
Displays
Must display Sp02 and heart rate. Signal strength is added value.
Display must be backlit and easily visible in the dark.
Sp02
Range must be greater than 1-100%
Accuracy must be +/- 3%, added value if accuracy is +/- 2% or more accurate.
Pulse Rate
Range must be greater than 30-240bpm, added value if range is closer to 20-300bpm
Accuracy must be +/- 5bpm including with motion. Added value if accuracy is +/- 2bpm or more accurate.
Perfusion Index And/Or Signal Strength Indicator
Signal strength indicator is added value.
Response Time
Added value for lower response times
Alarms
Must be visual and audible
Patient alarms must include out-of-range Sp02 and heart rate.
Equipment alarms must include low battery and probe disconnection
User must be able to control volume and/or silence alarm
Self-Test Mode
Must offer self-test mode
Probe Types
Must include reusable adult digit and ear probes
Cable length must be greater than 2 ft
Dimensions and Weight
Must fit comfortably in the user's hand
Battery
Must have replaceable battery option
- ONE VA CENTER
- TOGUS , ME 04330
- USA
- Manases Cabrera
- manases.cabrera@va.gov
- Phone Number 781-687-4418
- Jul 08, 2025 11:30 am EDTSources Sought (Original)
Related Document
| Jul 31, 2025 | [Combined Synopsis/Solicitation (Original)] Oximeters Nellcor™ Portable SpO2 Patient Monitoring System, Model PM10 Brand Name or Equal |
See Also
Follow Dapagliflozin Tablets Active Contract Opportunity Notice ID SPE2D2-26-R-0018 Related Notice Department/Ind. Agency
DEPT OF DEFENSE
Follow Progesterone Capsules Active Contract Opportunity Notice ID SPE2D2-26-R-0015 Related Notice SPE2D2-26-R-0015 Department/Ind.
DEPT OF DEFENSE
Due by 9/18/2026
Follow 65--SURVIVAL KIT,INDIVIDUA Active Contract Opportunity Notice ID SPE2DS26T414R Related Notice Department/Ind. Agency
DEPT OF DEFENSE
Due by 9/15/2026
Follow 6505--Ticagrelor Tablets Active Contract Opportunity Notice ID 36E79726R0028 Related Notice 36E79726R0028 Department/Ind.
VETERANS AFFAIRS, DEPARTMENT OF
Due by 9/17/2026