4310--Optical Lab Air Compressor Replacement Project, IND
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Indiana |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Dec 10, 2025 |
| Due Date: | Dec 17, 2025 |
| Solicitation No: | 36C25026Q0162 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
Follow
Active
Contract Opportunity
Notice ID
36C25026Q0162
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
250-NETWORK CONTRACT OFFICE 10 (36C250)
Looking for contract opportunity help?
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Dec 10, 2025 09:38 am EST
- Original Response Date: Dec 17, 2025 04:30 pm EST
- Inactive Policy: Manual
- Original Inactive Date: Jan 01, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 4310 - COMPRESSORS AND VACUUM PUMPS
-
NAICS Code:
- 333912 - Air and Gas Compressor Manufacturing
-
Place of Performance:
Indianapolis VA Medical Center - Optical Lab Indianapolis , IN 46241USA
This is a REQUEST FOR INFORMATION and SOURCES SOUGHT for TWO Industrial Air Compressors
Contractors that deem themselves capable of meeting the requirement shall provide the below information to Brooke Hansen, Contracting Officer, at Brooke.Hansen@va.gov no-later-than Wednesday, December 17, 2025 at 4:30PM, EST, referencing (36C25026Q0162). Responses shall include: (1) Business Name and Address, (2) GSA Contract Number and expiration date, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size SMALL or LARGE (6) Type of Small Business (if applicable): service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard (8) Country of Origin. If the concern is the manufacture and the sole distributor, please provide documentation to that effect.
Please see requirements below:
Indianapolis VA Medical Center, located at 5610 Dividend Rd, STE B, Indianapolis, IN 46241, is requesting the purchase of TWO Ingersoll Rand RS55I, 75HP, 138 PSI Contact Cooled Rotary Screw with Total Air System or equivalent.
Project minimal specification requirements:
a. ON-SITE pre-proposal visitation by potential vendor is available, to ensure accuracy in the vendor s proposal to the government.
b. Two (2) units, each unit independently able to continuously provide the minimally acceptable air demand requirements (335 CFM) of the VA Optical Lab, installed in tandem, to allow continuous, uninterrupted supply of air, regardless of which air compressor is operational. The VA currently owns a 500-gallon (approximate) air storage tank.
c. Each air compressor unit shall include an integrated air-drying system.
d. Variable speed/rotary design is preferred, but not mandatory.
e. Fully turn-key project management/installation
- Removal and scrapping of two (2) existing units IR model IRN40H-CC-HV air compressors
- Transportation and all rigging of outgoing & incoming equipment
- Integration and exhaust duct work required to place both new air compressor units in the most acceptable location in the VA s mechanical room- core ductwork is present.
- All utilities hook-up and/or modification required to optimize new air compressor requirements. Presently, the VA has one (1) 100A/60V safety switch, and one (1) 200A/240V safety switch.
- All drain requirements of the new air compressors.
- All plumbing & material requirements to tie into or modify present air supply lines (4 copper) to optimize new equipment replacement/location.
- Relocation of existing 500-gallon (approximate) air storage tank to optimize new equipment replacement/location.
f. Awarded vendor must be able to offer an optional, Preventative Maintenance program (to be solicitated and awarded later) to support this equipment for the OEM estimated life of these air compressors.
Contractors that deem themselves capable of meeting the requirement shall provide the below information to Brooke Hansen, Contracting Officer, at Brooke.Hansen@va.gov no-later-than Wednesday, December 17, 2025 at 4:30PM, EST, referencing (36C25026Q0162). Responses shall include: (1) Business Name and Address, (2) GSA Contract Number and expiration date, if applicable (3) Point of Contact Name, Phone Number and E-mail Address (4) DUNS and NAICS code (5) Business Size SMALL or LARGE (6) Type of Small Business (if applicable): service disabled veteran owned, veteran owned small business, 8a, HUBZone, woman-owned, etc. (7) A concern that is not a manufacturer of the supply shall provide the manufacturers name and size standard (8) Country of Origin. If the concern is the manufacture and the sole distributor, please provide documentation to that effect.
Please see requirements below:
Indianapolis VA Medical Center, located at 5610 Dividend Rd, STE B, Indianapolis, IN 46241, is requesting the purchase of TWO Ingersoll Rand RS55I, 75HP, 138 PSI Contact Cooled Rotary Screw with Total Air System or equivalent.
Project minimal specification requirements:
a. ON-SITE pre-proposal visitation by potential vendor is available, to ensure accuracy in the vendor s proposal to the government.
b. Two (2) units, each unit independently able to continuously provide the minimally acceptable air demand requirements (335 CFM) of the VA Optical Lab, installed in tandem, to allow continuous, uninterrupted supply of air, regardless of which air compressor is operational. The VA currently owns a 500-gallon (approximate) air storage tank.
c. Each air compressor unit shall include an integrated air-drying system.
d. Variable speed/rotary design is preferred, but not mandatory.
e. Fully turn-key project management/installation
- Removal and scrapping of two (2) existing units IR model IRN40H-CC-HV air compressors
- Transportation and all rigging of outgoing & incoming equipment
- Integration and exhaust duct work required to place both new air compressor units in the most acceptable location in the VA s mechanical room- core ductwork is present.
- All utilities hook-up and/or modification required to optimize new air compressor requirements. Presently, the VA has one (1) 100A/60V safety switch, and one (1) 200A/240V safety switch.
- All drain requirements of the new air compressors.
- All plumbing & material requirements to tie into or modify present air supply lines (4 copper) to optimize new equipment replacement/location.
- Relocation of existing 500-gallon (approximate) air storage tank to optimize new equipment replacement/location.
f. Awarded vendor must be able to offer an optional, Preventative Maintenance program (to be solicitated and awarded later) to support this equipment for the OEM estimated life of these air compressors.
Attachments/Links
Contracting Office Address
- VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
- DAYTON , OH 45428
- USA
Primary Point of Contact
- Brooke Hansen
- brooke.hansen@va.gov
- Phone Number Phoned inquiries will not be accepted.
Secondary Point of Contact
- Dec 10, 2025 09:38 am ESTSources Sought (Original)
Get Government Bids Like This by Email
Receive daily bid alerts that match your keywords, business categories, and target regions.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.