Olink Explorer >5400
| Agency: | HEALTH AND HUMAN SERVICES, DEPARTMENT OF |
|---|---|
| State: | Maryland |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | No Set aside used |
| Posted Date: | Jul 15, 2026 |
| Due Date: | Jul 25, 2026 |
| Solicitation No: | 75N98026Q00800 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Original)
- Original Published Date: Jul 15, 2026 12:12 pm EDT
- Original Date Offers Due: Jul 25, 2026 09:00 am EDT
- Inactive Policy: Manual
- Original Inactive Date: Jul 26, 2026
-
Initiative:
- None
- Original Set Aside: No Set aside used
- Product Service Code: Q301 - REFERENCE LABORATORY TESTING
-
NAICS Code:
- 541380 - Testing Laboratories and Services
-
Place of Performance:
Bethesda , MD 20892USA
Requirements:
2.0 BACKGROUND
Our lab studies the role of inflammation/innate resistance and commensal microbiota in carcinogenesis, cancer progression and therapy of cancer.
The following product features/characteristics are required for this requirement:
Protein Coverage - Measures ~5,400+ human proteins simultaneously in a single workflow.
Technology - Uses Proximity Extension Assay (PEA) with dual antibody recognition coupled to DNA barcoding and next-generation sequencing (NGS) readout.
Sample input – requires only 2 ul of plasma, serum, and other sample types
Specificity - Reported 99.5% specificity with negligible cross-reactivity due to dual-recognition antibody design.
Dynamic Range - Approximately 10 orders of magnitude (fg/mL to mg/mL), enabling detection of both low- and high-abundance proteins.
Key strengths
- Very broad proteome coverage while maintaining antibody-based specificity.
- Excellent sensitivity for low-abundance circulating proteins (especially cytokines and signaling proteins).
- Extremely low sample-volume requirement.
- Highly standardized platform, making it attractive for epidemiology and multi-omics studies.
- 6011 EXECUTIVE BLVD., SUITE 503L
- BETHESDA , MD 20892
- USA
- John Burton
- burtonjo@mail.nih.gov
- Jul 15, 2026 12:12 pm EDTSolicitation (Original)
See Also
Bid Number: BPM058461 Bid Title: Community Needs Assessment Category: Other Departments Status: Open
Queen Anne County
Due by 9/16/2026
Project: E-Filing Service Provider Certification (Open & Continuous) Ref. #: E-Filing Service Provider
Maryland Courts
Due by 4/22/2036
Project ID: Title: Jail Medical and Mental Health Services Addenda: 0 Release Date:
St. Mary's County
Due by 9/30/2026
ID: BPM058622 Title: 27-05, Mobile Health Services Expansion Initiative Status: Open Due /
State Government of Maryland
Due by 9/17/2026