| Agency: | State Government of Ohio |
|---|---|
| State: | Ohio |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Jun 3, 2026 |
| Due Date: | Jun 18, 2026 |
| Solicitation No: | SRC0000039872 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
| Solicitation ID: | SRC0000039872 |
| Solicitation Name: | ODOC Air Quality Monitoring Re-Calibration and Repair |
| Original Begin Date: | 6/3/2026 2:08:23 PM |
| Begin Date: | 6/3/2026 2:08:23 PM |
| End Date: | 6/18/2026 5:00:00 PM |
| Inquiry End Date: | 6/12/2026 8:00:00 AM |
| Commodity: | Gas detectors |
| MBE Set Aside: | MBE Set Aside |
| Agency: | COM650000 State Fire Marshal COMSFM |
| Solicitation Status: | Open for Bidding |
| Solicitation Type: | Request for Quote (RFQ) |
|
In an MBE set-aside solicitation, only those bidders/suppliers with an active MBE certification at the time the solicitation closes can submit a response
|
|||
|
Solicitation ID
SRC0000039872
|
|||
|
Solicitation Name
ODOC Air Quality Monitoring Re-Calibration and Repair
|
RFx Type
Request for Quote (RFQ)
|
||
|
Lot #
1
|
Solicitation Status
Open for Bidding
|
||
|
Round #
1
|
MBE Set Aside
|
||
|
Begin Date
6/3/2026 2:08:23 PM (ET)
|
Amendment?
|
||
|
End Date
6/18/2026 5:00:00 PM (ET)
|
Inquiry End Date
6/12/2026 8:00:00 AM
|
||
|
Summary
The Ohio Department of Commerce (COM), Division of the Division of State Fire Marshal is requesting Fiscal Year 2027 (July 1, 2026 – June 30, 2027) quotes for: 2 Brasch monitoring stations and for troubleshooting current error codes.
The A-Building on the DSFM campus has an environmental control system for the apparatus bays. The control system is now controlled by two (2) Brasch (Model: GSE2-NCM-24) monitoring stations. This system monitors hazardous gases that are produced when running a gasoline or diesel engine. When readings reach a specified (dangerous) level, a series of exhaust fans turn on automatically to expel the hazardous gasses. In addition, a make-up air unit (HVAC) is simultaneously triggered to bring in fresh, tempered air the apparatus bays are not experiencing a negative-pressure air space. All these components work in synchrony to keep the air at a safe level for occupants. All these components rely on the environment control system sensor. The sensor is a permanent part of the environment control system. It has two sensors inside the unit that detect nitrogen dioxide (product of diesel engines) and carbon monoxide (product of gasoline engines). These units require a calibration upgrade/renewal every two-to-three years - including replacement of both modules that detect NO2 and CO in both sensors. There are two units located in the apparatus bays, one on the north side and one on the south that need service. They are due for new calibration kits and, at least one sensor is showing a communication issue error “9203”. DSFM is requesting for both sensors to have new kits installed (new CO and NO2 modules), calibrate as necessary and to troubleshoot the error code on the north sensor. • S/N: SA-21746 – GSE2-NCM-24 (north sensor) • S/N: SA-21745 - GSE2-NCM-24 (south sensor) Work location: ATTN: Michael Sands COM SFM-ADM 8895 East Main St. 43068 Reynoldsburg Ohio UNITED STATES Terms & Conditions: The State Standard Terms and Conditions apply to this solicitation. No additional terms and conditions will be accepted. Bidders must include a PDF copy of their bid on company letterhead, and should include the vendor e-mail and a contact number. All bids shall be good for a minimum of 90 days from the COM solicitation closing date to be considered. Selection will be based on the lowest responsive and responsible bid. COM reserves the right to make no award under this solicitation. COM reserves the right to reject any and all bids, in whole or in part, received in response to this RFQ. COM may cancel or reissue this RFQ for any reason. |
Predecessor Contract
|
||
|
Process
Itemized Quote.
The quote shall be itemized and include the following: estimated shipping, company name, contact information, including name, phone number and email to which COM should remit the purchase order.
|
|||
|
Ship To
|
|||
1 Record(s)
|
0 Record(s)
|
1 Record(s)
|
With Free Trial, you can:
You will have a full access to bids, website, and receive daily bid report via email and web.
Follow J045--Boiler Tuning Services at the Chalmers P Wylie VA Ambulatory Care Center
Federal Agency
Bid Due: 6/26/2026
Solicitation #: RFQ033092 Requesting Department: Public Service Document Title: DPS - 5913 -
City of Columbus
Bid Due: 7/16/2026
Description: Maintenance, Repair, and Operational (MRO) Supplies Department: Procurement Buyer: Sarah Dolly Solicitation
City of Cincinnati
Bid Due: 6/25/2026
Project: Maintenance, Repair, & Operational (MRO) Supplies Ref. #: 265X901150 Department: Various Agencies
City of Cincinnati
Bid Due: 6/25/2026