459MXS Equipment Ventilation
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | Maryland |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Total Small Business Set-Aside (FAR 19.5) |
| Posted Date: | Aug 22, 2025 |
| Due Date: | Aug 27, 2025 |
| Solicitation No: | FA286025Q4051 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Aug 22, 2025 11:25 am EDT
- Original Response Date: Aug 27, 2025 04:00 pm EDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Sep 11, 2025
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
JB Andrews , MD 20762USA
Provide and install 8" CPVC pipe and fittings from the existing parts washer exhaust pipe to outside the building. The existing 8” CVPC pipe will need to be extended and supported vertically approximately 14 feet. Then the pipe will need to run horizontally approximately 28 feet and exit building above the hangar doors on the north side of hangar 11. The horizontal pipe will need to be supported from the concrete ceiling as required. The ceiling is approximately 3 feet above where the horizontal pipe will run. The area that the vent will exit the building is corrugated steel and will need to be cut to allow for the exhaust pipe to exit the hangar. This area will need to be sealed around the exhaust pipe once installed. The exhaust pipe will also require some type of barrier to prevent birds and other rodents from entering.
-See attached statement of work and photos for more information.
***This sources sought is for market research only and does not obligate the Government. It is not a solicitation and cannot be accepted to form a contract. The Government will not reimburse costs for responding, and no work is authorized without a contract signed by a warranted Contracting Officer.***
- CP 240 612 5676 1349 LUTMAN DR
- JB ANDREWS , MD 20762-7001
- USA
- Amn Zwe Naing
- zwe.naing@us.af.mil
- TSgt Andrea Begens
- andrea.begens@us.af.mil
- Aug 22, 2025 11:25 am EDTSources Sought (Original)
See Also
ID: BPM059606 Title: CEGENE30SB Generator repair at SHA Elkton Status: Open Due /
State Government of Maryland
Due by 11/19/2026
Follow Service Contract for Carl Zeiss LSM 900 Confocal Microscope System Active Contract
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 11/20/2026
Contract Number & Title Anticipated Advertising Date Pre-Bid Meeting Bid Opening Date MAA-MC-28-002
BWI Airport
ID: BPM059820 Title: LIFE SAFETY AND SECURITY MONITORING, MAINTENANCE, AND REPAIRS Status: Open
State Government of Maryland
Due by 12/22/2026