6550 - Molecular Diagnostic Laboratory Reagents (Kits)
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Oregon |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | No Set aside used |
| Posted Date: | Aug 18, 2026 |
| Due Date: | Sep 11, 2026 |
| Solicitation No: | 36C26026Q0957 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Aug 18, 2026 01:40 pm PDT
- Original Response Date: Sep 11, 2026 05:00 pm PDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Sep 26, 2026
-
Initiative:
- None
- Original Set Aside: No Set aside used
- Product Service Code: 6550 - IN VITRO DIAGNOSTIC SUBSTANCES, REAGENTS, TEST KITS AND SETS
-
NAICS Code:
- 325413 - In-Vitro Diagnostic Substance Manufacturing
-
Place of Performance:
Portland , OR 97239USA
Vendor will provide Test Kits as needed to perform testing on VA owned molecular analyzer, located in the VA Portland Medical Center Microbiology Department.
The instrument processes kits that must utilize a multiplex PCR (polymerase chain reaction) method, have FDA-cleared assays that simultaneously tests for as many as 20 respiratory pathogen targets, has testing capability to test for common GI pathogens including viruses, bacteria, and parasites with at least 20 targets, at least 40 blood culture identification targets, and up to 14 meningitis/encephalitis targets inclusive of bacteria, viruses and fungi.
The method should have very little hands-on time (2 minutes or less) to set up and have results for respiratory pathogen targets, blood culture, GI pathogens and meningitis/encephalitis targets in one hour. The technique must perform amplification, detection and analysis in one self-contained system. The VA equipment includes software that automatically generates a result for each target in a single report.
- 1601 E Fourth Plain Blvd Bldg 17 Suite B428
- VANCOUVER , WA 98661
- USA
- Eric A Lingenfelter
- Eric.Lingenfelter@va.gov
- Phone Number 3608529891
- Aug 18, 2026 01:40 pm PDTSources Sought (Original)
See Also
Bid Solicitation: S-44300-00001160 Responses Due in 1826 Days, 1 Hours, 28 Minutes Header
State Government of Oregon
Due by 11/09/2026
Follow Warm Springs Service Unit Optical Coherence Tomography with Angiography Installation, Calibration, and
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 5/08/2029
Bid Solicitation # S-58100-00017752 Bid Solicitation # S-58100-00017752 Organization Name Department of Education
State Government of Oregon
Due by 9/16/2026
Follow Dental Equipment Active Contract Opportunity Notice ID 75H71326Q00068 Related Notice Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Due by 9/15/2026