MICROWAVE THERAPY SYSTEM
| Agency: | DEPT OF DEFENSE |
|---|---|
| State: | North Carolina |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | No Set aside used |
| Posted Date: | May 12, 2026 |
| Due Date: | May 21, 2026 |
| Solicitation No: | W81K0426QA059 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: May 12, 2026 02:26 pm EDT
- Original Response Date: May 21, 2026 10:00 am EDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Jun 05, 2026
-
Initiative:
- None
- Original Set Aside: No Set aside used
- Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
-
NAICS Code:
- 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
-
Place of Performance:
Fort Bragg , NC 28310USA
This is a Request for Information (RFI) – Sought Notice Only. This notice is issued solely for information and planning purposes only.
1. The US Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder; not responding to this notice does not preclude participation in any further RFQ; IFB or RFP if issued.
2. The associated North American Industry Classification System (NAICS) is 334510. The business size standard is 750 Employees. All contractors doing business with the Department of Defense shall be registered and approved through the System for Award Management (SAM). This is the Official U.S. Government system that consolidates the capabilities of CCR/FedReg, and EPLS. There is no fee to register for this site. Entities may register at no cost directly from this page. The proposed performance start date will be on or about 1 July 2026. The Solicitation number is W81K0426QA043.
3. Note – Prior to award your company shall reflect the NAICS Code 334510 identified on your SAM. If your company is interested in competing on this project, and have services, please submit the following documentation no later than 21 May 2026, 10:00 AM EST, to Cynthia A. Richardson-Rhone and Jason Holck at cynthia.a.richardson-rhone.civ@health.mil.
Your email response shall provide the following:
Can you provide the following:
General System Description
The Intelli Blate Microwave Ablation System is a software-controlled microwave therapy delivery platform intended for the coagulation (ablation) of soft tissues. The system utilizes microwave energy to produce controlled, spherical ablation zones and features integrated cooling, real-time temperature monitoring, and advanced probe placement functions.
Generator (Console) Specifications
- Operating Frequency 2.45 GHz ± 50 MHz
- Ablation Channels Must support at least two (2) independent ablation channels, allowing for single-probe, dual-independent, or dual-linked probe operations
- Output Power Single Channel: 0 to 90 Watts. Dual Channel: 0 to 80 Watts per channel (up to 160 Watts linked)
- Power Adjustments Output power must be adjustable in 5-Watt increments.
- Safety Shut off Must feature an automatic system shutdown if probe temperatures or reflected power exceed established safety limits
- Dimensions & Weight Console alone must weigh no more than 40 lbs. (approx. 38 lbs.) for portability and mount securely to a customized mobile cart
User Interface & Display
- Monitor 15.6-inch foldable, high-resolution color touchscreen
- Ergonomics Screen must be capable of swiveling 180 degrees (CW/CCW) to allow visibility from any operating position. Must be fully operable with gloved hands or through a sterile drape
- Visual Feedback Interface must provide real-time tracking of time, tip power, reflected energy (power), and multi-point temperature data
Integrated Cooling System
- Pump Mechanism Must feature two (2) fully integrated peristaltic pumps built directly into the console (one for each ablation channel)
- Coolant Compatibility Must be compatible with standard, user-supplied sterile water or 0.9% saline (1000 mL bags or greater)
- Cassette Loading Must utilize a drop-in, integrated fluid cassette system to streamline coolant delivery and prevent setup errors
Probe Assembly Characteristics (Ximitry Probes)
- Antenna Profile 13.5 Gauge (2.3 mm diameter) fiberglass shaft with a ceramic trocar tip
- Available Lengths Must be available in at least three lengths: 15 cm, 20 cm, and 27 cm
- Integrated Temperature Sensing Probe must contain at least three (3) integrated thermocouples along the shaft and two (2) internal temperature sensors within the handle for continuous, real-time thermal feedback
- Cable Management Must utilize a single-cable bundle that integrates both the RF power cable and the coolant tubing (supply and return lines) into one cord
- Visual Indicators Probe handles must include integrated LED indicators to visually signal when microwave energy is actively being delivered
Advanced Clinical Workflow Features
- Needle Lock Must include a feature that delivers a short, calculated burst of microwave energy to secure the radiating section of the probe to the tissue, mitigating accidental probe migration during setup or intra-procedural imaging
- Tract Ablation Must include a specific track ablation/cauterization mode to safely ablate the tissue along the insertion tract (4-10 mm) during probe retraction to prevent bleeding and tumor seeding.
- External Temperature Monitoring System must support the connection of up to two (2) remote/external Temperature Sensor Probes to monitor collateral tissue temperatures independently from the ablation probes
- System Integration Must be capable of integrating with advanced 3D planning and laser guidance software (e.g., my Ablation Guide, my Needle Companion) and support laser alignment discs on the probe handles.
Please ensure to address the below:
Name of Company
Point of contact
Phone number
Email address
Identify Your Small Business Socio-Economic Group
DUNS number and CAGE Code
4. This requirement No telephonic inquiries will be responded to. A solicitation will be posted within 2-3 weeks www.Sam.gov.
- HEALTH READINESS CONTRACTING OFFICE 2199 STORAGE ST BLDG 4197 STE 68
- JBSA FT SAM HOUSTON , TX 78234-5074
- USA
- cynthia a. Richardson-rhone
- cynthia.a.richardson-rhone.civ@health.mil
- Phone Number 9109079310
- Jason Holck
- jason.t.holck.mil@health.mil
- May 12, 2026 02:26 pm EDTSources Sought (Original)
See Also
RFB #26-075 WC Mini City EMS Station RFB #26-075 Wake County Mini City
Wake County
Due by 9/24/2026
Solicitation Number: 377-IFB 2026-040 Project Title: IFB 2026-040 UC EMS Revovation Description: Scope
State Government of North Carolina
Due by 9/16/2026
Follow Mobile (MRI) Trailer Lease Active Contract Opportunity Notice ID 36C24627Q0008 Related Notice
VETERANS AFFAIRS, DEPARTMENT OF
Due by 9/16/2026
DL00382 POC 50984.3.2, ETC. - INSTALLATION OF SINUSOIDAL RUMBLE STRIPS & THERMO PAVEMENT
Division of Highways
Due by 9/22/2026