Marydia to Hansel 69kV Storm Hardening Project-Tubular Steel Transmission Poles
| Agency: | Kissimmee Utility Authority |
|---|---|
| State: | Florida |
| Type of Government: | State & Local |
| NAICS Category: |
|
| Posted Date: | Aug 11, 2026 |
| Due Date: | Aug 25, 2026 |
| Solicitation No: | IFB 26-042-JG |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
Main
Agency
Kissimmee Utility Authority
Kissimmee Utility Authority
Status
Active
Active
Fiscal Year
2026
2026
Title
Marydia to Hansel 69kV Storm Hardening Project-Tubular Steel Transmission Poles
Marydia to Hansel 69kV Storm Hardening Project-Tubular Steel Transmission Poles
Number
IFB 26-042-JG
IFB 26-042-JG
Tertiary Contact
Type
Invitation to Bid
Invitation to Bid
Department
Operations
Operations
Online Submissions
Yes
Yes
Project Estimate
Piggyback Solicitation
No
No
Insurance Required
Yes
Yes
Bid Bond Required
No
No
Bid Bond Amount
Performance Bond Required
Yes
Yes
Performance Bond Amount
100%
100%
Construction Bond Required
No
No
Construction Bond Amount
Scope of Services
It is the intent of this invitation for bid to engage with a successful Bidder(s) to
purchase transmission structures for the Marydia - Hansel Storm Hardening project for
Kissimmee Utility Authority (KUA) based on a fixed price, in accordance with the
following specifications listed herein. It is understood that there may be additions
or deletions to the list specified herein during the life of this contract as dictated by
KUA’s service protocols.
It is the intent of this invitation for bid to engage with a successful Bidder(s) to
purchase transmission structures for the Marydia - Hansel Storm Hardening project for
Kissimmee Utility Authority (KUA) based on a fixed price, in accordance with the
following specifications listed herein. It is understood that there may be additions
or deletions to the list specified herein during the life of this contract as dictated by
KUA’s service protocols.
Dates(All times are listed as
EST
)
Broadcast Date
7/10/2026 8:00 AM EST
7/10/2026 8:00 AM EST
Question End Date
7/28/2026 2:00 PM EST
7/28/2026 2:00 PM EST
Sample Due Date
Due Date
8/25/2026 2:00 PM EST
8/25/2026 2:00 PM EST
Bid Opening Date
Question End Date Reminder Notification
1 Day(s)
1 Day(s)
Sample Due Date Reminder Notification
0 Day(s)
0 Day(s)
Due Date Reminder Notification
1 Day(s)
1 Day(s)
Pre-Bid Meetings
Total: 0
(All times are listed as
EST
)
| Date | Time | Mandatory | Location |
Shortlist Meeting
Total: 0
(All times are listed as
EST
)
| Date | Time | Location |
Documents
Total: 5
Quote/Bid
Quote/Bid Items
Additional Quote/Bid Items Fields
Quote/Bid Items
Total: 0
| # | Required | Group | Make | Model | Description | Quantity | Unit of Measure | Price/ Percent | Type |
Delivery Date
None
None
Required Files to be Uploaded by the Vendor
Pricing Sheet
IFB Response
Pricing Sheet
IFB Response
Shipping
FOB Destination
FOB Destination
Terms and Conditions
See KUA`s Terms and Conditions
See KUA`s Terms and Conditions
Include Shipping in Price of Items
Yes
Yes
Display Bid Tabulation to Vendors
No
No
Display Vendor Submissions to Vendors
No
No
View Vendor Submissions while Bid Solicitation is Active
No
No
Allow Options File to be Updated after Due Date
No
No
Allow Post Due Date Submission
No
No
Questions & Answers
Total: 5
| Question | Date Asked | Answer | Date Answered |
|
Dear KUA Team,
Load tests are normally avoided for Transmission poles due to high cost and delays in delivery. Moreover it`s only one pole per per type, each one with a load test!. Can you confirm this load test is rally needed? |
7/13/2026 7:11:51 PM | KUA has removed the load test requirement for this project. | 8/10/2026 10:05:56 AM |
|
For structures 9194, the load values appear to be corrupted (refer to the image below), and the same values are shown for all load cases. Could you please provide the correct load table for this structure.
|
7/20/2026 11:35:35 AM | Please see the revised steel pole load trees for clarity. | 8/10/2026 10:06:14 AM |
|
Please confirm the loading information for the following structures:
Structure 9194: The loading table appears to be inconsistent. Could you please confirm that the loading values shown are correct? Structure 9195: The loading table does not include the Ahead and Back components. Based on the current loading, the structure appears to represent a dead-end condition rather than a tangent structure. Could you please confirm that the loading values are correct, or provide an updated loading table if necessary? |
7/20/2026 7:40:35 PM | Please see the revised steel pole load trees for clarity. | 8/10/2026 10:06:29 AM |
|
1. Regarding the position where the load be applied
There are eight pairs the load point(red part in the below table) in the load table, but these loading positions did not mark on the drawings. Please provide the position on the pole where these loads should be applied. |
7/24/2026 10:21:45 AM | KUA has removed the load test requirement for this project. | 8/10/2026 10:07:06 AM |
|
2. Regarding the arm
a. The 2.02B.4 item In the MVAB26096 TUBULAR STEEL SPECIFICATION said “Arm Shape: Provide 4-sided arm sections”. Can the arm be changed to 6 sided ? b. Based on diagram of the arm in the drawing, There seems to be a rise at small end of arm. Could you provide the rise size? |
7/24/2026 10:23:24 AM | The distribution arm design should meet the provided horizontal length and loading requirements. Any necessary design changes to the arm shape or rise are acceptable. | 8/10/2026 10:07:25 AM |
Commodity Codes
Total: 3
| Code | Description |
| [725-42] | Poles, Metal, Transmission, High Voltage (EFFECTIVE 3-1-07 THIS CLASS-ITEM INACTIVATED FOR NEW USE, REFER TO 839-60) |
| [839-60] | Poles, High Voltage Transmission |
| [320-20] | Bolts, Steel |
Publications
Total: 0
| Publication | Date |
Get Government Bids Like This by Email
Receive daily bid alerts that match your keywords, business categories, and target regions.
See Also
RFQ-26-D-00044 26-D-00044 Assessment of Fire Station 6, 9, &10 for Renovation View Details
City of Tampa
Due by 10/08/2026
RFQ-26-D-00044 26-D-00044 Assessment of Fire Station 6, 9, &10 for Renovation View Details
City of Tampa
Due by 10/08/2026
Follow Construct Concrete Targets Active Contract Opportunity Notice ID FA248826RB001 Related Notice Department/Ind.
DEPT OF DEFENSE
Due by 10/09/2026
Project ID: Title: McIntosh Park Wetland Construction Addenda: 0 Release Date: 8/19/2026 Due
City of Plant City
Due by 10/08/2026
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.