6640-- Maldi Contract Request
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Texas |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Apr 14, 2026 |
| Due Date: | Apr 20, 2026 |
| Solicitation No: | 36C25726Q0465 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Apr 14, 2026 12:12 pm CDT
- Original Response Date: Apr 20, 2026 09:00 am CDT
- Inactive Policy: Manual
- Original Inactive Date: Jun 19, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
-
NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
-
Place of Performance:
Department of Veteran Affairs Dallas VA North Texas Health Care System Dallas , TX 75216USA
I. General Information
- Agency/Office: Department of Veterans Affairs (VA), VA North Texas Health Care System (VANTHCS), Dallas, TX.
- Place of Performance: VA North Texas Health Care System, Pathology and Laboratory Medicine Service (P&LMS), Microbiology Laboratory, Dallas, Texas.
- Anticipated NAICS: 334516 Analytical Laboratory Instrument Manufacturing (or other NAICS determined appropriate for MALDI TOF instrumentation).
- Anticipated PSC: 6640 Laboratory Equipment and Supplies.
The Government is seeking to identify responsible vendors capable of providing a Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry Biotyper System (MALDI TOF), brand name or equal, configured and supported as described below for use in organism identification in the Microbiology Laboratory at VANTHCS.
II. Description of Requirement
VANTHCS requires the purchase (outright equipment acquisition) of one Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry Biotyper System (MALDI TOF) and associated operating software to support high throughput, rapid identification of bacteria, fungi, and mycobacteria in the Pathology and Laboratory Medicine Service Microbiology laboratory. The system will be installed on site and integrated with the existing Beckman Coulter Microscan 96 plus / LabPro MBT solution. Testing for bacteria must be FDA cleared for in vitro diagnostic use and classified as CLIA high or moderately complex testing.
The contemplated purchase includes, at a minimum:
- One MALDI TOF Biotyper instrument (true benchtop system, small footprint, approximately 165 pounds, low noise) suitable for placement on a laboratory desktop or compatible table. Â
- Instrument specific, proprietary software required for organism identification, including MBT Compass HT 1890605, MBT Explorer Module, MBT HT Mycobacteria Module, and MBT HT Subtyping Module, plus applicable proprietary software upgrades (no third party software, and hardware upgrades for compatibility are excluded). Â
- Mycobacteria Module software and any future upgrades there to be made available during the warranty period. Â
- A MALDI TOF instrument and configuration compatible with LabPro MBT for a fully automated, LIS integrated solution with existing Beckman Coulter Microscan systems, without additional middleware. Interface connectivity support and training by a Beckman Coulter Microscan Systems application specialist must be included at no additional cost to the Government. Â
- Installation, verification/validation, and initial technical assistance by the instrument manufacturer, including set up in accordance with CLIA, FDA, The Joint Commission (TJC), College of American Pathologists (CAP), and manufacturer requirements. Â
- On site training for Clinical Laboratory Scientists in the Microbiology laboratory, including lesson plans, course materials, and training handouts for all relevant procedures at no additional cost. Â
- Uninterruptible power supply (UPS) suitable for the system. Â
- Delivery of all operational, maintenance, troubleshooting, small repair, equipment specification, and test manuals. Â
Reagents and consumable supplies will be procured separately under a different purchase agreement.
III. Salient System and Performance Characteristics
Vendors capable of providing a brand name or equal MALDI TOF Biotyper System shall demonstrate that their offered system meets or exceeds at least the following **salient** characteristics:
- System configuration Â
 - True benchtop MALDI TOF mass spectrometry system with small footprint and low noise profile, not exceeding approximately 165 pounds, suitable for standard laboratory benchtops or compatible instrument tables. Â
-Electrical Data: 220V/110V.
-LXWXH :500X710X1070 mm (19.7 X 28.0 X42.2 inches).
- Weight:75kg (165.4 lbs) net weight.
- Temperature Range:16-30 degree Celsius. Operating Humidity:20-75% non-condensing.
 - Integrated ion source cleaning capability. Â
 - High capacity vacuum system enabling fast target exchange and minimized downtime following maintenance. Â
- Operational performance Â
 - Random access operation; samples must not be restricted to batch only testing. Â
 - Capability to perform testing for bacteria, fungi, and mycobacteria. Â
 - Ability to identify bacteria in less than one hour from prepared target to result, under normal operating conditions. Â
 - Testing for bacteria is FDA cleared for in vitro diagnostic use and classified as CLIA high or moderately complex. Â
- Software, LIS and interface Â
 - Built in instrument software that is directly compatible with, and provides a fully automated, LIS integrated solution with, the existing Beckman Coulter Microscan 96 plus / LabPro MBT without the need for separate middleware. Â
 - Provision of latest LabPro MBT compatible software and reference libraries (including fungi and mycobacteria libraries). Â
 - Interfacing of the MALDI TOF system with the existing Beckman Coulter Microscan systems, including all required configuration and testing, at no additional cost to the Government. Â
IV. Submission Instructions
Interested and capable vendors should submit an electronic capability statement and include the place of manufacture for all equipment and reagents via email in PDF or Word format by April 21, 2026 by 9:00 AM Central Standard Time.
- Teresa Arzola Â
- Email: Teresa.arzola@va.gov Â
- Subject line: Sources Sought MALDI TOF Biotyper System VA North Texas HCS Â
No telephone inquiries will be accepted. Responses received will be used solely for market research and planning purposes to assist the Government in determining an appropriate acquisition strategy (e.g., small business set aside or unrestricted).
Submission of a capability statement is voluntary and shall not be construed as a commitment by the Government to issue a solicitation or award a contract, nor will the Government pay for information submitted in response to this Sources Sought.
- 5441 Babcock Road Suite 302
- San Antonio , TX 78240
- USA
- Teresa Arzola
- Teresa.Arzola@va.gov
- Phone Number 5441 Babcock Rd. Ste. 302
- Apr 14, 2026 12:12 pm CDTSources Sought (Original)
See Also
Follow Hypobaric Chamber Pilot Studies Active Contract Opportunity Notice ID 80JSC026Q0006 Related Notice
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION
Due by 10/01/2026
RFP 2026-024 City-Owned Historic Property Reuse Follow Solicitation Solicitation ID: 2026-024-01 Status: Posted
State Government of Texas
Due by 10/08/2026
Project ID: 26-101-13 Title: Automated Weather Observing System (AWOS III-PT) - Ennis Municipal
Ennis city
Due by 9/23/2026
Follow New - CAP - One Year Requirement Active Contract Opportunity Notice ID
VETERANS AFFAIRS, DEPARTMENT OF
Due by 9/18/2026