Mainland High - Baseball Field Lighting

Agency: Volusia County Schools
State: Florida
Type of Government: State & Local
NAICS Category:
  • 238210 - Electrical Contractors and Other Wiring Installation Contractors
Posted Date: Apr 28, 2026
Due Date: May 14, 2026
Solicitation No: Project No. 2648275
Original Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Mainland High - Baseball Field Lighting - Project No. 2648275
Mandatory Prebid Meeting: April 28, 2026 at 10:00 AM
Bid: May 14, 2026 at 1:30 PM
Project Bid Documents: Plans
Project Manual
Prebid Sign-in
Estimate: $1,005,000
Consultant: Matern Professional Engineering, Inc.
Adrian Baus

(407) 740-5020
Owner: VCS Project Manager
Jim Bott

(386) 947-8786
Bid Status: Active

Attachment Preview

130 Candace Drive Maitland, FL 32751 ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365 MPE JOB #2:025-135
E
ADDING BASEBALL FIELD LIGHTING TO THE EXISTING BASEBALL FIELD AS SHOWN ON THESE DRAWINGS AND DESCRIBED IN THE PROJECT MANUAL. Engineer's Statement of Compliance To the best of my knowledge, these drawings and the project manual are complete and comply with the Florida Building Code.
BUILDING DATA
A. SURVEY PARCEL ID XXX B. LEGAL DESCRIPTION XXX C. OCCUPANCY TYPE Educational D. CONSTRUCTION TYPE XXX E. RISK CATEGORY XXX F. AUTOMATIC SPRINKLER XXX G. BUILDING AREA XXX H. BUILDING HEIGHT XXX I. OCCUPANT LOAD XXX
LOCATION MAP
SHEET INDEX
SHEET NO. SHEET NAME SCALE
G001 COVER SHEET NONE
E001 GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS NONE
E100 SITE PLAN - ELECTRICAL 1" = 50'
E101 PARTIAL SITE PLAN - ELECTRICAL - RENOVATION 1" = 20'-0"
E102 PARTIAL SITE PLAN - ELECTRICAL - RENOVATION 1" = 20'-0"
E501 DETAILS NONE
E502 DETAILS NONE
E503 DETAILS NONE
E504 DETAILS NONE
E601 POWER RISER DIAGRAM AND SCHEDULES NONE
E602 SCHEDULES NONE
ETAD
DESIGNED BY AWB DRAWN BY MM
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE COVER SHEET

SCHOOL BOARD
MAINLAND HIGH
MEMBERS
BASEBALL FIELD
LIGHTING
VCS Project NO. 2648275
DESCRIPTION OF WORK ENGINEERS & CONSULTANTS
ADDING BASEBALL FIELD LIGHTING TO THE EXISTING BASEBALL FIELD AS SHOWN ON THESE DRAWINGS AND DESCRIBED IN
THE PROJECT MANUAL.
Engineer's Statement of Compliance
To the best of my knowledge, these drawings and the project manual are complete and comply with
the Florida Building Code.
BUILDING DATA
A. SURVEY PARCEL ID XXX
B. LEGAL DESCRIPTION XXX
C. OCCUPANCY TYPE Educational
D. CONSTRUCTION TYPE XXX
E. RISK CATEGORY XXX
F. AUTOMATIC SPRINKLER XXX
G. BUILDING AREA XXX
H. BUILDING HEIGHT XXX
I. OCCUPANT LOAD XXX
LOCATION MAP
NOT TO SCALE
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
VOLUSIA 130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
COUNTY SCHOOLS MPE JOB #2:025-135
"LEADING WITH GRACE AND RESPECT" Ruben Colon Board Chair
Krista Goodrich Board Vice Chair
Donna Brosemer Member
Jamie Haynes Member
THE SCHOOL BOARD OF VOLUSIA Jessie Thompson Member
COUNTY FLORIDA
200 North Clara Avenue Carmen J. Balgobin Superintendent
DeLand, Florida 32720
MATERN PROFESSIONAL ENGINEERING
130 Candace Drive
Maitland, Fl 32715
407-740 -5020
Adrian Baus
abaus@matern.net 130 Candace Drive
http://matern.net Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
ARCH/ENGR OF RECORD
Engineer
Adrian Baus
DESIGNED BY DRAWN BY
AWB MM
ISSUE DATE AE PROJECT NUMBER
02/20/2026 2025-135
SHEET TITLE
COVER SHEET
CONSTRUCTION DOCUMENTS 02/20/2026
DRAWING NO.
G001
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
1255 W INTERNATIONAL SPEEDWAY
BLVD, DAYTONA BEACH, FL 32114
SHEET INDEX
SHEET
SHEET NAME SCALE
NO.
G001 COVER SHEET NONE
E001 GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS NONE
E100 SITE PLAN - ELECTRICAL 1" = 50'
E101 PARTIAL SITE PLAN - ELECTRICAL - RENOVATION 1" = 20'-0"
E102 PARTIAL SITE PLAN - ELECTRICAL - RENOVATION 1" = 20'-0"
E501 DETAILS NONE
E502 DETAILS NONE
E503 DETAILS NONE
E504 DETAILS NONE
E601 POWER RISER DIAGRAM AND SCHEDULES NONE
E602 SCHEDULES NONE

ETAD
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE AE PROJECT NUMBER 02/20/2026 2025-135 SHEET TITLE
GENERAL NOTES, SYMBOL LEGEND, AND ABBREVIATIONS

"
34"
"
ARCH/ENGR OF RECORD
DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
GENERAL NOTES,
SYMBOL LEGEND,
AND ABBREVIATIONS
E001

ETAD
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE SITE PLAN - ELECTRICAL

ARCH/ENGR OF RECORD
DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
SITE PLAN - ELECTRICAL
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
SITE PLAN -
ELECTRICAL
E100

ETAD
DESIGNED BY DRAWN BY AWB MM/AWB
ISSUE DATE AE PROJECT NUMBER 02/20/2026 2025-135 SHEET TITLE PARTIAL SITE PLAN - ELECTRICAL - RENOVATION

ARCH/ENGR OF RECORD
DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
PARTIAL SITE PLAN - ELECTRICAL - RENOVATION
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
PARTIAL SITE PLAN -
ELECTRICAL -
RENOVATION
E101
AREA OF WORK PARTIAL KEYPLAN

AREA OF WORK
ETAD
DESIGNED BY DRAWN BY AWB MM/AWB
ISSUE DATE AE PROJECT NUMBER 02/20/2026 2025-135 SHEET TITLE PARTIAL SITE PLAN - ELECTRICAL- RENOVATION DRAWING NO.

ARCH/ENGR OF RECORD
DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
PARTIAL SITE PLAN - ELECTRICAL - RENOVATION
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
AREA OF WORK
PARTIAL SITE PLAN -
ELECTRICAL-
RENOVATION
E102
PARTIAL KEYPLAN

POLE DECRIPTION #LUMINAIRES/POLE LUMINAIRE FIXTURE GROUP MOUNTING MODEL POLE HEIGHT HEIGHT CONTACTOR FLA CONTACTOR SIZ E CIRCUIT SIZE ZONE
A2 BASEBALL 4 MUSCO TLC- LED-1500 80' C-BT-575 80' 19' C1 12.74 30 20 B
1 MUSCO TL
A3 BASEBALL 4 MUSCO TLC- LED-1500 80' C-BT-575 80' 16' C2 12.74 30 20 B
1 MUSCO TL
B2 BASEBALL 6 MUSCO TLC- LED-1500 80' C-BT-575 80' 80' 80 16' C3 15.00 30 20 B
1 MUSCO TL
B3 BASEBALL 6 MUSCO TLC- LED-1500 80' C-BT-575 80' 80' 80 16' C4 15.00 30 20 B
1 MUSCO TL
C1 BASEBALL 5 MUSCO TLC- LED-1500 70' C-BT-575 70' 70' 16' C5 12.74 30 20 B
2 MUSCO TL
C2 BASEBALL 5 MUSCO TLC- LED-1500 70' C-BT-575 70' 70' 16' C6 12.75 30 20 B
2 MUSCO TL
TOTAL 38 80.97
LUMINAIRE DESCRIPTION
TYPE SOURCE WATT AGE MAX AMPS LUMENS L90 L80 L70
TLC-LED-1500 LED 5700K - 75 CRI 1410 W ATTS 3.6 181,000 >120,000 >120,000 >120,000
TLC-LED-1200 LED 5700K - 75 CRI 1170 W ATTS 3.0 150,000 >120,000 >120,000 >120,000
TLC-LED-900 LED 5700K - 75 CRI 880 WA TTS 2.3 104,000 >120,000 >120,000 >120,000
TLC-BT-575 LED LED 5700K - 75 CRI 575 WA TTS 1.5 52,000 >120,000 >120,000 >120,000
2 1 7 2 3 4 14 5 6" 6 1 7 4" (*) (*) 10 12 8 4 13 3 10 9 10 4" 10 14 6 5 8 5" * 9 11 11 12 13 14 FLUSH GRADE HANDHOLE DETAIL - 'PBD2'
CALCULATON GRID SUMMARY
GRID NAME CALCULATION METRIC AVERAGE MINIMUM MAXIMUM MAX/MIN ZONES OPERATIN
INFIELD HORIZONTAL ILLUMINANCE 51.05 36.14 63.36 1.75 B
OUTFIELD HORIZONTAL ILLUMINANCE 33.97 24.7 44.50 1.80 B
ETAD
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE DETAILS

BASEBALL FIELD POLE /FIXTURE SCHEDULE
FIXTURE GROUP
MOUNTING
POLE DECRIPTION #LUMINAIRES/POLE LUMINAIRE MODEL POLE HEIGHT HEIGHT CONTACTOR FLA CONTACTOR SIZE CIRCUIT SIZE ZONE PANEL /CKT
A2 BASEBALL 4 MUSCO TLC-LED-1500 80'
1 MUSCO TLC-BT-575 80' 19' C1 12.74 30 20 B HBBF-1:3:5
A3 BASEBALL 4 MUSCO TLC-LED-1500 80'
1 MUSCO TLC-BT-575 80' 16' C2 12.74 30 20 B HBBF-7:9:11
B2 BASEBALL 6 MUSCO TLC-LED-1500 80'
1 MUSCO TLC-BT-575 80'
80' C3 15.00 30 20 B HBBF-13:15:17
80
16'
B3 BASEBALL 6 MUSCO TLC-LED-1500 80'
1 MUSCO TLC-BT-575 80'
80' C4 15.00 30 20 B HBBF-19:21:23
80
16'
C1 BASEBALL 5 MUSCO TLC-LED-1500 70'
2 MUSCO TLC-BT-575 70' 70' C5 12.74 30 20 B HBBF-25:27:29
16'
C2 BASEBALL 5 MUSCO TLC-LED-1500 70'
2 MUSCO TLC-BT-575 70' 70' C6 12.75 30 20 B HBBF-31:33:35
16'
TOTAL 38 80.97
LUMINAIRE DESCRIPTION
TYPE SOURCE WATTAGE MAX AMPS LUMENS L90 L80 L70 QUANTITY
TLC-LED-1500 LED 5700K - 75 CRI 1410 WATTS 3.6 181,000 >120,000 >120,000 >120,000 30
TLC-LED-1200 LED 5700K - 75 CRI 1170 WATTS 3.0 150,000 >120,000 >120,000 >120,000
TLC-LED-900 LED 5700K - 75 CRI 880 WATTS 2.3 104,000 >120,000 >120,000 >120,000
TLC-BT-575 LED LED 5700K - 75 CRI 575 WATTS 1.5 52,000 >120,000 >120,000 >120,000 8
CALCULATON GRID SUMMARY
# FIXTURES
GRID NAME CALCULATION METRIC AVERAGE MINIMUM MAXIMUM MAX/MIN ZONES OPERATING
OPERATING
INFIELD HORIZONTAL ILLUMINANCE 51.05 36.14 63.36 1.75 B 38
OUTFIELD HORIZONTAL ILLUMINANCE 33.97 24.7 44.50 1.80 B 38
2 1
7
2
3
4
14
5
6"
6
1
7
4"
(*)
(*)
10
12
8
4
13 3
10 9
10 4"
10
14 6
5
8
5" * ARCH/ENGR OF RECORD
9
11 11 DESIGNED BY DRAWN BY
12
ISSUE DATE AE PROJECT NUMBER
13
14
DRAWING NO.
FLUSH GRADE HANDHOLE DETAIL - 'PBD2'
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
DETAILS
E501

GROUND WELL DETAIL (MAIN SERVICE) FOR GRASSY UNPAVED NON-TRAFFIC AREAS
CHILLER CH-1 HEAT TAPE 20 AMP 120V 1PH 2W FED FROM 1L1-73 LOCATED IN BUILDING 1 ROOM 01-142 TYPICAL NAMEPLATE
GROUND WELL DETAIL - POLE LIGHTING
ETAD
WARNIN !
Arc Flash and Shock H Appropriate PPE Requ
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE DETAILS

DISCONNECT RACK (DOUBLE) -
FREESTANDING/GRADE MOUNTED
GROUND WELL DETAIL (MAIN SERVICE) FOR
GRASSY UNPAVED NON-TRAFFIC AREAS
CHILLER CH-1
HEAT TAPE
20 AMP 120V 1PH 2W
FED FROM
1L1-73 LOCATED IN
BUILDING 1 ROOM 01-142
WARNING
!
Arc Flash and Shock Hazard
Appropriate PPE Required
NOTES
PROVIDE/INSTALL SIGN ON ALL EQUIPMENT PER ANSI, NEC, AND OSHA.
ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, PROVIDES GUIDELINES FOR
THE DESIGN OF SAFETY SIGNS AND LABELS FOR APPLICATION TO PRODUCTS.
TYPICAL NAMEPLATE
"ARC FLASH AND
ARCH/ENGR OF RECORD
SHOCK HAZARD" SIGN GROUND WELL DETAIL - POLE LIGHTING
N.T.S AFSH DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
DETAILS
E502

NOITPIRCSED
ETAD
LIGHTING FIXTURE SCHEDULE
VCS - MAINLAND HIGH
TYPE SLB DESCRIPTION ONE (1) ARM MOUNTED LED SHOEBOX LUMINAIRE, TYPE V DISTRIBUTION, DARK BRONZE COLOR, MOUNT 20'-0" AFG TO DIRECT BURIED CONCRETE POLE WITH 155 MPH WIND LOADING BASED ON EMBEDMENT IN SAND APPROVED DESIGN SELECTION SUBSTITUTION LEOTEK LIGHTING # CURRENT LIGHTING # ASL1 160L-115 4K7 5QW UNV MAF SP DBT POLE: SEMINOLE POLES # 28FT PRE-CAST SPECIALTIES (NOTE 9 & 10) (NOTE 9 & 10) APPROVED VOLTS SUBSTITUTION LITHONIA/ACUITY# 277 # CCT 4000K WATTAGE 110 LUMENS 15,632 LAM LE
SLC ONE (1) ARM MOUNTED LED SHOEBOX LUMINAIRE, TYPE III DISTRIBUTION, DARK BRONZE COLOR, MOUNT 20'-0" AFG TO DIRECT BURIED CONCRETE POLE WITH 155 MPH WIND LOADING BASED ON EMBEDMENT IN SAND LEOTEK LIGHTING # CURRENT LIGHTING # ASL1 160L-115 4K7 3 UNV MAF SP DBT POLE: SEMINOLE POLES # 28FT PRE-CAST SPECIALTIES (NOTE 9 & 10) (NOTE 9 & 10) LITHONIA/ACUITY# 277 # 4000K 110 15,413 LE
LIGHTING FIXTURE SCHEDULE GENERAL NOTES: (1) CONTRACTOR SHALL CAREFULLY COORDINATE THE LIGHTING FIXTURE TRIM TYPES WITH THE TYPE OF CEILING WHERE THE LIGHTING FIXTURES ARE TO BE INSTALLED. MODIFY FIXTURE CATALOG NUMBER AS REQUIRED TO COORDINATE FIXTURE WITH CEILIN (2) ALL FIXTURES TO HAVE IN-LINE FUSE AND FUSE HOLDER. (3) PROVIDE MANUFACTURER'S POINT BY POINT PHOTOMETRIC ANALYSIS FOR SITE LIGHTING WITH SUBMITTALS 10 DAYS PRIOR TO BID FOR APPROVAL BY DESIGN ENGINEER.. PROVDIE EMBEDMENT DETAILS FOR SAND (4) CONTRACTOR, AT HIS OPTION, MAY USE A U.L. LISTED FLEXIBLE WIRING SYSTEM FOR LIGHTING FIXTURE BRANCH CIRCUITRY ABOVE ACCESSIBLE LAY-IN CEILINGS. ALL HOMERUNS, CONNECTIONS TO LIGHT SWITCHES, AND BRANCH CIRCUITRY FOR ALL OTHE CEILING CONDITIONS SHALL BE IN A CONVENTIONAL RACEWAY SYSTEM PER SPECIFICATIONS. (5) WHEN FIXTURE MODEL NUMBER DIFFERS FROM FIXTURE DESCRIPTION, CONTRACTOR IS TO SUBMIT RFI REQUESTING CLARIFICATION PRIOR TO BID, PRIOR TO SHOP DRAWING SUBMITTAL AND PRIOR TO ORDERING OF FIXTURE. WHERE CONTRACTOR DOES NO REQUEST CLARIFICATION PRIOR TO BID, CONTRACTOR SHALL PROVIDE THE MOST EXPENSIVE OPTION BETWEEN A FIXTURE THAT MATCHES THE DESCRIPTION AND A FIXTURE THAT MATCHES THE MODEL NUMBER. AFTER BID, CONTRACTOR SHALL SUBMIT RFI REQUESTING CLARIFICATION SO PROPER FIXTURE GETS SUBMITTED, PROVIDED AND INSTALLED. (6) MOUNT LINEAR FIXTURES TOGETHER, END TO END, WHERE SHOWN IN CONTINUOUS ROWS. (7) MANUFACTURER SHALL PROVIDE A WARRENTY AGAINST LOSS OF PERFORMANCE AND DEFECTS IN MATERIALS AND WORKMANSHIP FOR THE LUNINAIRS FOR A PERIOD OF 10 YEARS AFTER ACCEPTANCE OF THE LUMINAIRES. WARRANTY SHALL COVER ALL COMPONENTS COMPRISING THE LUMINAIRE. (8) AT TIME OF PURCHASE, ALL APPROVED MANUFACTURERS MUST BE USING CREE, PHILLIPS, SAMSUNG, BRIDGELUXE LED'S, NO OTHER LED MANUFACTURERS ARE PERMITTED. (9) PROVIDE SEPARATE SLEEVE IN CONCRETE POLES FOR LIGHTNING PROTECTION DOWN CONDUCTOR. (10) PROVIDE MANUFACTURER'S POINT BY POINT PHOTOMETRIC ANALYSIS FOR SITE LIGHTING WITH SUBMITTALS.
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE DETAILS

PHOTOCONTROL TIME CLOCK SCHEMATIC - MXB
BASE DETAIL - CONCRETE LIGHT POLE
LIGHTING FIXTURE SCHEDULE
VCS - MAINLAND HIGH
APPROVED APPROVED
TYPE DESCRIPTION DESIGN SELECTION VOLTS CCT WATTAGE LUMENS LAMP
SUBSTITUTION SUBSTITUTION
LEOTEK LIGHTING #
ONE (1) ARM MOUNTED LED SHOEBOX LUMINAIRE, TYPE V CURRENT LIGHTING #
DISTRIBUTION, DARK BRONZE COLOR, MOUNT 20'-0" AFG ASL1 160L-115 4K7 5QW UNV MAF SP DBT
SLB POLE: LITHONIA/ACUITY# 277 4000K 110 15,632 LED
TO DIRECT BURIED CONCRETE POLE WITH 155 MPH WIND SEMINOLE POLES # 28FT
PRE-CAST SPECIALTIES #
LOADING BASED ON EMBEDMENT IN SAND (NOTE 9 & 10)
(NOTE 9 & 10)
LEOTEK LIGHTING #
ONE (1) ARM MOUNTED LED SHOEBOX LUMINAIRE, TYPE III CURRENT LIGHTING #
DISTRIBUTION, DARK BRONZE COLOR, MOUNT 20'-0" AFG ASL1 160L-115 4K7 3 UNV MAF SP DBT
SLC POLE: LITHONIA/ACUITY# 277 4000K 110 15,413 LED
TO DIRECT BURIED CONCRETE POLE WITH 155 MPH WIND SEMINOLE POLES # 28FT
PRE-CAST SPECIALTIES #
LOADING BASED ON EMBEDMENT IN SAND (NOTE 9 & 10)
(NOTE 9 & 10)
LIGHTING FIXTURE SCHEDULE GENERAL NOTES:
(1) CONTRACTOR SHALL CAREFULLY COORDINATE THE LIGHTING FIXTURE TRIM TYPES WITH THE TYPE OF CEILING WHERE THE LIGHTING FIXTURES ARE TO BE INSTALLED. MODIFY FIXTURE CATALOG NUMBER AS REQUIRED TO COORDINATE FIXTURE WITH CEILING.
(2) ALL FIXTURES TO HAVE IN-LINE FUSE AND FUSE HOLDER.
(3) PROVIDE MANUFACTURER'S POINT BY POINT PHOTOMETRIC ANALYSIS FOR SITE LIGHTING WITH SUBMITTALS 10 DAYS PRIOR TO BID FOR APPROVAL BY DESIGN ENGINEER.. PROVDIE EMBEDMENT DETAILS FOR SAND
(4) CONTRACTOR, AT HIS OPTION, MAY USE A U.L. LISTED FLEXIBLE WIRING SYSTEM FOR LIGHTING FIXTURE BRANCH CIRCUITRY ABOVE ACCESSIBLE LAY-IN CEILINGS. ALL HOMERUNS, CONNECTIONS TO LIGHT SWITCHES, AND BRANCH CIRCUITRY FOR ALL OTHER
CEILING CONDITIONS SHALL BE IN A CONVENTIONAL RACEWAY SYSTEM PER SPECIFICATIONS.
(5) WHEN FIXTURE MODEL NUMBER DIFFERS FROM FIXTURE DESCRIPTION, CONTRACTOR IS TO SUBMIT RFI REQUESTING CLARIFICATION PRIOR TO BID, PRIOR TO SHOP DRAWING SUBMITTAL AND PRIOR TO ORDERING OF FIXTURE. WHERE CONTRACTOR DOES NOT
REQUEST CLARIFICATION PRIOR TO BID, CONTRACTOR SHALL PROVIDE THE MOST EXPENSIVE OPTION BETWEEN A FIXTURE THAT MATCHES THE DESCRIPTION AND A FIXTURE THAT MATCHES THE MODEL NUMBER. AFTER BID, CONTRACTOR SHALL SUBMIT RFI
REQUESTING CLARIFICATION SO PROPER FIXTURE GETS SUBMITTED, PROVIDED AND INSTALLED.
(6) MOUNT LINEAR FIXTURES TOGETHER, END TO END, WHERE SHOWN IN CONTINUOUS ROWS. ARCH/ENGR OF RECORD
(7) MANUFACTURER SHALL PROVIDE A WARRENTY AGAINST LOSS OF PERFORMANCE AND DEFECTS IN MATERIALS AND WORKMANSHIP FOR THE LUNINAIRS FOR A PERIOD OF 10 YEARS AFTER ACCEPTANCE OF THE LUMINAIRES. WARRANTY SHALL COVER ALL
COMPONENTS COMPRISING THE LUMINAIRE.
DESIGNED BY DRAWN BY
(8) AT TIME OF PURCHASE, ALL APPROVED MANUFACTURERS MUST BE USING CREE, PHILLIPS, SAMSUNG, BRIDGELUXE LED'S, NO OTHER LED MANUFACTURERS ARE PERMITTED.
(9) PROVIDE SEPARATE SLEEVE IN CONCRETE POLES FOR LIGHTNING PROTECTION DOWN CONDUCTOR. ISSUE DATE AE PROJECT NUMBER
(10) PROVIDE MANUFACTURER'S POINT BY POINT PHOTOMETRIC ANALYSIS FOR SITE LIGHTING WITH SUBMITTALS.
PHOTOCONTROL CONTACTOR MXA SCHEMATIC - MXA
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
DETAILS
E503

POLE DECRIPTION #LUMINAIRES/POLE LUMINAIRE MODEL POLE HEIGHT FIXTURE GROUP MOUNTING HEIGHT CONTACTOR FLA CONTACTOR SIZE CIRCUIT SIZE ZONE PANEL /CKT
A1 SOFTBALL 1 MUSCO TLC-LED-1200 70' 70' C1 5.17 30 15 A HBBF-2:4:6
2 MUSCO TLC-LED-550 16'
1 MUSCO TLC-BT-575
A2 SOFTBALL 1 MUSCO TLC-LED-1200 80' 70' C2 5.17 30 15 A HBBF-8:10:12
2 MUSCO TLC-LED-550 16'
1 MUSCO TLC-BT-575
B1 SOFTBALL 5 MUSCO TLC-LED-1500 80' 80' C3 12.47 30 20 A HBBF-14:16:18
1 MUSCO TLC-LED-550 80'
1 MUSCO TLC-BT-575 16'
B2 SOFTBALL 5 MUSCO TLC-LED-1500 80' 80' C4 12.47 30 20 A HBBF-20:22:24
MUSCO TLC-LED-550 80'
1 MUSCO TLC-BT-575 16'
TOTAL 21 35.28
LUMINAIRE DESCRIPTION
TYPE SOURCE WATTAGE MAX AMPS LUMENS L90 L80 L70 QUANTITY
TLC-LED-1500 LED 5700K - 75 CRI 1410 WATTS 3.6 181,000 >120,000 >120,000 >120,000 10
TLC-LED-1200 LED 5700K - 75 CRI 1170 WATTS 3.0 150,000 >120,000 >120,000 >120,000 2
TLC-LED-900 LED 5700K - 75 CRI 880 WATTS 2.3 104,000 >120,000 >120,000 >120,000
TLC-LED-550 LED 5700K - 75 CRI 540 WATTS 1.4 67,000 >120,000 >120,000 >120,000 5
TLC-BT-575 LED LED 5700K - 75 CRI 575 WATTS 1.5 52,000 >120,000 >120,000 >120,000 4
ETAD
CALCULATON GRID SUMMARY
GRID NAME CALCULATION METRIC AVERAGE MINIMUM MAXIMUM MAX/MIN ZONES OPERATING # FIXTURES OPERATING
INFIELD HORIZONTAL ILLUMINANCE 50.29 34.91 64.33 1.84 A 21
OUTFIELD HORIZONTAL ILLUMINANCE 31.43 18.42 42.88 2.33 A 21
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE DETAILS

SOFTBALL FIELD POLE /FIXTURE SCHEDULE
FIXTURE GROUP
MOUNTING
POLE DECRIPTION #LUMINAIRES/POLE LUMINAIRE MODEL POLE HEIGHT HEIGHT CONTACTOR FLA CONTACTOR SIZE CIRCUIT SIZE ZONE PANEL /CKT
A1 SOFTBALL 1 MUSCO TLC-LED-1200 70'
2 MUSCO TLC-LED-550 70' 16' C1 5.17 30 15 A HBBF-2:4:6
1 MUSCO TLC-BT-575
A2 SOFTBALL 1 MUSCO TLC-LED-1200 70'
2 MUSCO TLC-LED-550 80' 16' C2 5.17 30 15 A HBBF-8:10:12
1 MUSCO TLC-BT-575
B1 SOFTBALL 5 MUSCO TLC-LED-1500 80'
1 MUSCO TLC-LED-550 80' 80' C3 12.47 30 20 A HBBF-14:16:18
1 MUSCO TLC-BT-575 16'
B2 SOFTBALL 5 MUSCO TLC-LED-1500 80'
MUSCO TLC-LED-550 80' 80' C4 12.47 30 20 A HBBF-20:22:24
1 MUSCO TLC-BT-575 16'
TOTAL 21 35.28
LUMINAIRE DESCRIPTION
TYPE SOURCE WATTAGE MAX AMPS LUMENS L90 L80 L70 QUANTITY
TLC-LED-1500 LED 5700K - 75 CRI 1410 WATTS 3.6 181,000 >120,000 >120,000 >120,000 10
TLC-LED-1200 LED 5700K - 75 CRI 1170 WATTS 3.0 150,000 >120,000 >120,000 >120,000 2
TLC-LED-900 LED 5700K - 75 CRI 880 WATTS 2.3 104,000 >120,000 >120,000 >120,000
TLC-LED-550 LED 5700K - 75 CRI 540 WATTS 1.4 67,000 >120,000 >120,000 >120,000 5
TLC-BT-575 LED LED 5700K - 75 CRI 575 WATTS 1.5 52,000 >120,000 >120,000 >120,000 4
CALCULATON GRID SUMMARY
# FIXTURES
GRID NAME CALCULATION METRIC AVERAGE MINIMUM MAXIMUM MAX/MIN ZONES OPERATING
OPERATING
INFIELD HORIZONTAL ILLUMINANCE 50.29 34.91 64.33 1.84 A 21
OUTFIELD HORIZONTAL ILLUMINANCE 31.43 18.42 42.88 2.33 A 21
ARCH/ENGR OF RECORD
DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
DETAILS
E504

FEEDER SCHEDULE: BASEBALL FIELD DATE: 2/17/2026 COPYRIGHT: ME, LLC 2009VERSION: A8d5R1 REV: 1-7-2021
FEEDER FEEDING OCP AMP SIZE VOLTS FEEDER AMPACITY FEEDER VOLTAGE DROP (%) WIRE/PHASE NEUTRAL WIRE GROUND WIRE EXTRA NEUTRAL FEEDER MATERIAL PARALLEL RUNS CONDUIT SIZE (IN) SHORT CIRCUIT AMPS AT PANEL
HBBF 250 480 248 2% #350 KCMIL #350 KCMIL #2 COPPER 1 4 10243
POLE A2 (BASEBALL CKT) 30 480 40 1% #8 #8 #8 COPPER 1 1
POLE A3 30 480 40 2% #8 #8 #8 COPPER 1 1
POLE B2 (BASEBALL CKT) 30 480 40 0% #8 #8 #8 COPPER 1 1
POLE B3 30 480 30 2% #6 #6 #6 COPPER 1 1
POLE C1 30 480 40 1% #8 #8 #8 COPPER 1 1
POLE C2 30 480 30 2% #6 #6 #6 COPPER 1 1
LBBF 175 208 175 0% #2/0 #2/0 #4 COPPER 1 2.5 1946
LBBF XFMR PRI 70 480 85 0% #4 ----- #8 COPPER 1 1.5 8085
ETAD
DESIGNED BY AWB DRAWN BY MM/AWB
ISSUE DATE 02/20/2026 AE PROJECT NUMBER 2025-135
SHEET TITLE POWER RISER DIAGRAM AND SCHEDULES

FEEDER SCHEDULE: BASEBALL FIELD DATE: 2/17/2026 COPYRIGHT: ME, LLC 2009VERSION: A8d5R1 REV: 1-7-2021
SHORT
OCP FEEDER
FEEDER NEUTRAL GROUND EXTRA FEEDER PARALLEL CONDUIT CIRCUIT
FEEDER FEEDING AMP VOLTS VOLTAGE WIRE/PHASE
AMPACITY WIRE WIRE NEUTRAL MATERIAL RUNS SIZE (IN) AMPS AT
SIZE DROP (%)
PANEL
HBBF 250 480 248 2% #350 KCMIL #350 KCMIL #2 COPPER 1 4 10243
POLE A2 (BASEBALL CKT) 30 480 40 1% #8 #8 #8 COPPER 1 1
POLE A3 30 480 40 2% #8 #8 #8 COPPER 1 1
POLE B2 (BASEBALL CKT) 30 480 40 0% #8 #8 #8 COPPER 1 1
POLE B3 30 480 30 2% #6 #6 #6 COPPER 1 1
POLE C1 30 480 40 1% #8 #8 #8 COPPER 1 1
POLE C2 30 480 30 2% #6 #6 #6 COPPER 1 1
LBBF 175 208 175 0% #2/0 #2/0 #4 COPPER 1 2.5 1946
LBBF XFMR PRI 70 480 85 0% #4 ----- #8 COPPER 1 1.5 8085 "
GENERAL NOTES:
1) CONDUIT SIZE IS BASED ON 2020 N.E.C. FOR EMT, IMC, RMC, FLEXIBLE METAL, AND SCHED 40 PVC. IF ANY OTHER TYPE OF CONDUIT/TUBING IS USED, THE
CONTRACTOR SHALL RESIZE CONDUIT AND SIZE AS REQUIRED TO COMPLY WITH THE N.E.C..
2) USE CABLE REDUCERS AT TERMINATIONS AND/OR AT/IN JUNCTION BOX NEAR TERMINATIONS AS REQUIRED TO COORDINATE OVERSIZED PHASE OR
NEUTRAL CONDUCTORS WITH TERMINATION LUG SIZE OR PROVIDE TERMINATION/LUGS SIZED FOR FEEDERS.
3) CONTRACTOR IS TO MEGGER TEST ALL FEEDERS PER SPECIFICATIONS.
4) WHERE DISCONNECT SWITCH (DISC SW) IS INCLUDED IN THE NAME UNDER "FEEDER FEEDING", PROVIDE DISC SW TO MEET ALL ELECTRICAL
CHARACTERISTICS PER THIS SCHEDULE, INCLUDING SCCR RATING. PROVIDE FUSE IN FUSIBLE SWITCHES OR PROVIDE UPSTREAM CIRCUIT BREAKER,
WHERE NON-FUSED SWITCHES ARE USED, AS REQUIRED BY DISCONNECT SWITCH MANUFACTURER FOR SHORT CIRCUIT AMPS SHOWN.
ARCH/ENGR OF RECORD
DESIGNED BY DRAWN BY
ISSUE DATE AE PROJECT NUMBER
DRAWING NO.
SNOISIVER
YROTSIH
TNEMUCOD
NOITPIRCSED
ETAD
.ON
130 Candace Drive
Maitland, FL 32751
ENG. BUS. No. EB-0005096 PHONE (407) 740-5020
CERT. OF AUTH. No. 5096 FAX (407) 740-0365
Engineer
Adrian Baus
AWB MM/AWB
02/20/2026 2025-135
SHEET TITLE
HGIH
DNALNIAM
GNITHGIL
DLEIF
LLABESAB
5728462
.ON
tcejorP
SCV
,DVLB
YAWDEEPS
LANOITANRETNI
W
5521
41123
LF
,HCAEB
ANOTYAD
POWER RISER DIAGRAM
AND SCHEDULES
E601

This page summarizes the opportunity, including an overview and a preview of the attached documents.
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Description: West Boynton Park - Lighting Replacement Department: Facilities Dev & Ops Buyer:

Palm Beach County

Bid Due: 9/26/2029

Description: West Boynton Park - Lighting Replacement Department: Facilities Dev & Ops Buyer:

Palm Beach County

Bid Due: 3/20/2030

Description: West Boynton Park - Lighting Replacement Department: Purchasing Buyer: Jonathan Silva Solicitation

Palm Beach County

Bid Due: 9/26/2029

Description: West Boynton Park - Lighting Replacement Department: Purchasing Buyer: Jonathan Silva Solicitation

Palm Beach County

Bid Due: 2/28/2030