| AS REQUIRED BY ROCK ISLAND COUNTY, IL, ENGINEERING DESIGN IS BASED ON AND ACCORDANCE |
| WITH THE FOLLOWING CODE(S) |
| STRUCTURAL DRAWINGS RE NOT STAND- |
ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN |
| CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER |
|
| DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS |
|
| INTO SHOP DRAWINGS AND WORK. |
|
| FOUNDATION DESIGN IS BASED ON PRELIMINARY DESIGN DRAWINGS RECEIVED FROM BUTLER MANUFACTURING. FINAL |
| DESIGN REACTIONS SUPPLIED BY THE SELECTED METAL BUILDING MANUFACTURER MAY DIFFER FROM PRELIMINARY |
| ESTIMATED REACTIONS. BASED ON FINAL REACTIONS SUPPLIED, MODIFICATIONS TO THE FOUNDATION PLAN MAY BE |
| REQUIRED. GENERAL CONTRACTOR SHALL INCLUDE IN THEIR BID AN ADD AND DEDUCT PRICE PER CUBIC YARD OF |
| CONCRETE WORK INSTALLED IN CASE SUCH CHANGES ARE REQUIRED. |
| INTERNATIONAL BUILDING CODE |
- |
2012 |
| CARR ENGINEERING, LLC |
|
|
| ILLINOIS DESIGN FIRM LIC No. |
|
|
| 184.007877 |
- |
0003 |
| COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS, DEPRESSIONS, ETC. WITH DRAWINGS FROM OTHER |
| DISCIPLINES, |
| SUPERIMPOSED ROOF DEAD LOAD ................................... BY METAL BUILDING MNFR. |
| FLOOR LIVE LOAD .................................................................. 250 PSF |
| METAL BUILDING MANUFACTURER SHALL ENGAGE A PROFESSIONAL ENGINEER LICENSED TO PRACTICE STRUCTURAL |
| ENGINEERING IN THE STATE OF ILLINOIS TO DESIGN THE METAL BUILDING AND TO SUBMIT STAMPED AND SEALED |
| DRAWINGS AND STRUCTURAL CALCULATIONS FOR THE METAL BUILDING. |
| SNOW LOAD: |
| 1) GROUND SNOW LOAD (Pg) .............................................. 20 PSF |
| 2) SNOW EXPOSURE FACTOR (Ce) ..................................... 1.0 |
| 3) SNOW IMPORTANCE FACTOR ......................................... 1.00 |
| 4) THERMAL FACTOR (Ct) ..................................................... 1.0 |
| 3294 Fields Dr. |
|
|
| Bettendorf, IA 52722 |
|
|
| (563) 503 |
- |
6100 |
| SPECIAL INSPECTION SHALL BE PROVIDED PER IBC 2012 CHAPTER 17. THE LIST BELOW IS A SUMMARY OF ITEMS |
| REQUIRING INSPECTION BY THE IBC: |
| ALL EXTERNAL LATERAL LOAD RESISTANCE AND STABILITY OF THE METAL BUILDING IN THE COMPLETED STRUCTURE IS |
| PROVIDED BY MOMENT FRAMES AND TENSION ONLY ROD BRACING. THE VERTICAL LATERAL MEMBERS CARRY THE |
| APPLIED LATERAL LOADS TO THE BUILDING FOUNDATION. THE TENSION ONLY ROD BRACING AT THE ROOF SERVES AS THE |
| HORIZONTAL DIAPHRAGM THAT DISTRIBUTES THE LATERAL WIND AND SEISMIC FORCES HORIZONTALLY TO THE VERTICAL |
| LATERAL MEMBERS. ALL LATERAL RESISTING MEMBERS ARE BY THE METAL BUILDING MANUFACTURER. |
| WIND LOAD |
| 1) BASIC WIND SPEED (3 SEC GUST) ................................. 115 MPH |
| 2) WIND IMPORTANCE FACTOR ...........................................1.0 |
| 3) BUILDING CATEGORY ....................................................... II |
| 4) WIND EXPOSURE ............................................................... C |
| 5) INTERNAL PRESSURE COEFFICIENT .............................. 0.18 |
| BUILDING. THE BUILDING MUST BE DESIGNED TO MEET THE LOADING INDICATED IN THE DRAWINGS AND THE DESIGN |
| CRITERIA INDICATED ABOVE. |
| SEISMIC |
|
| 1) SEISMIC DESIGN CATEGORY ........................................... B |
|
| 2) SEISMIC IMPORTANCE FACTOR ...................................... 1.00 |
|
| 3)SPECTRAL RESPONSE COEFFICIENTS |
|
|
Ss .......................................................................................... 0.19 |
|
S1 .......................................................................................... 0.085 |
| 4) SITE CLASS ......................................................................... D |
|
| 5)BASIC SEISMIC FORCE RESISTING SYSTEMS DESCRIPTION: |
|
|
STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE |
| OPERATIONS MAY BE MADE BY THE CONTRACTOR WITH APPROVAL FROM THE OWNER. DESIGN VALUES FROM THE 2012 IB |
| ARE AS FOLLOWS: |
| SEE METAL BUILDING DRAWINGS FOR ANCHOR ROD MATERIAL GRADE, ANCHOR ROD DIAMETERS, QUANTITIES AND |
| LAYOUT. |
| ALLOWABLE SOIL BEARING FOR FOOTING .......................................................................................... |
........................ |
| MINIMUM SOIL SUBGRADE MODULUS REQUIRED ...................................................................................... |
................ |
| THE TOP 9" (MIN.) OF THE EXISTING GRADE IS TO BE SCARIFIED AND RECOMPACTED TO MEET OR EXCEED THE REQUIREMENT |
| GIVEN IN THE GEOTECHNICAL REPORT. |
| FOR CAST- |
IN |
- |
PLACE CONCRETE THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR |
| REINFORCEMENT UNLESS NOTED OTHERWISE: |
|
|
|
| CONCRETE CAST AGAINST AND |
| PERMANENTLY EXPOSED TO EARTH |
| ENGINEER: REFERENCES OF THE STRUCTURAL DRAWINGS TO 'ENGINEER' MEAN THE |
| STRUCTURAL ENGINEER OF RECORD. OTHER ENTITIES ARE SPECIFICALLY NOTED AS |
| "CONTRACTORS ENGINEER", "MECHANICAL ENGINEER", ETC |
| WATER SHALL NOT BE ALLOWED TO ACCUMULATE IN THE EXCAVATION. PROVIDE PUMPS, IF NECESSARY, AND OPERAT |
| NIGHT AND DAY, WHENEVER REQUIRED |
| CONCRETE EXPOSED TO EARTH OR WEATHER |
| NO. 6 BARS OR LARGER |
| THE BASE OF ALL FOOTING EXCAVATIONS SHALL BE OBSERVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT |
| OF CONCRETE. |
| SLABS, WALLS, JOISTS NOT EXPOSED |
| TO WEATHER OR IN CONTACT WITH EARTH |
| NO. 14 AND NO. 18 BARS |
| BACKFILL PLACED WITHIN THE BUILDING AREA SHALL BE WITH SOIL THAT IS APPROVED BY THE GEOTECHNICAL ENGINEER. |
| PLACE IN LIFTS AND COMPACT IN STRICT COMPLIANCE WITH RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. |
| PLACE IN LOOSE LIFTS OF 8 INCHES OR LESS AND COMPACT. FILL SHOULD BE FREE OF FAT CLAYS AND ORGANIC SOIL |
| CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS |
| AND SITE OBSERVATION AS PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN. |
| CONTAMINANTS AND STONES THAT INTERFERE WITH COMPACTION OR COMPACTION TESTING. IN GENERAL, AT LEAST 70% |
|
|
|
| OF THE FILL SHOULD PASS A 3/4-I |
NCH SIEVE, THE OVER |
- |
SIZE LIMIT FOR THE ASTM D698 MAXIMUM DENSITY TEST. |
| DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS |
|
| WHICH ARE NOT NOW KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION |
|
| (DISCOVERY). CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CONDITIONS NOT |
|
| PER THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE: |
|
| - |
SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN. |
| - |
DAMAGE OR DETERIORATION TO MATERIALS OR COMPONENTS. |
| - |
ITEMS NOTED AS EXISTING ON THE DRAWINGS BUT NOT FOUND IN THE FIELD. |
| FILL SHOULD BE PLACES ON STABLE, UNFROZEN SURFACES AND IN NEARLY HORIZONTAL LIFTS THAT HAVE THICKNESSES |
|
|
|
| THAT ARE COMPATIBLE WITH THE COMPACTION EQUIPMENT USED, BUT GENERALLY NOT OVER EIGHT INCHES. ALL FILL |
|
|
|
| OTHER THAN COARSE AGGREGATES SHOULD BE COMPACTED TO AT LEAST 95% OF ITS MAXIMUM DRY DENSITY |
|
|
|
| DETERMINED BY ASTM D698, TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD |
|
|
|
| EFFORT (12,400 FT |
|
|
-LB/CUBIC FOOT). COMPACTION USUALLY REQUIRES ADJUSTMENTS OF FILL MOISTURE CONTENTS TO |
| WITHIN THREE PERCENTAGE POINTS OF THE ASTM D698 OPTIMUM MOISTURE. COARSE AGGREGATES SHOULD BE |
|
|
|
| VIBRATORY |
- |
COMPACTED TO INTERLOCK THE PARTICLES TO 98% STANDARD PROCTOR PER ASTM D698. |
|
| DIMENSIONS OF CONCRETE COVER FOR REINFORCEMENT INDICATED ON DRAWINGS ARE TO OUTERMOST |
| REINFORCING BARS. FOR BEAMS OR COLUMNS WITH STIRRUPS OR TIES, CLEAR COVER INDICATED IS TO STIRRUPS OR |
| TIES. |
| BAR SPLICES: SPLICE REINFORCING WHERE INDICATED ON THE DRAWINGS. ALL SPLICES SHALL BE CLASS 'B' AS |
| DEFINED IN ACI 318. IF SPLICE LENGTH IS NOT GIVEN ON THE DRAWINGS, PROVIDE LAP LENGTHS (IN INCHES) AS |
| FOLLOWS: |
|
|
|
3000 PSI CONC |
|
|
|
|
|
4000 PSI CONC |
|
|
|
|
|
| BAR SIZE |
|
|
OTHER |
|
|
TOP |
|
|
OTHER |
|
|
TOP |
|
|
|
#3 |
|
|
22 |
|
|
28 |
|
|
19 |
|
|
25 |
|
|
#4 |
|
|
29 |
|
|
38 |
|
|
25 |
|
|
33 |
|
|
#5 |
|
|
36 |
|
|
47 |
|
|
31 |
|
|
41 |
|
|
#6 |
|
|
43 |
|
|
56 |
|
|
37 |
|
|
49 |
|
|
#7 |
|
|
63 |
|
|
81 |
|
|
54 |
|
|
71 |
|
|
#8 |
|
|
72 |
|
|
93 |
|
|
62 |
|
|
81 |
|
|
#9 |
|
|
81 |
|
|
105 |
|
|
70 |
|
|
91 |
|
|
#10 |
|
|
91 |
|
|
118 |
|
|
79 |
|
|
102 |
|
|
#11 |
|
|
101 |
|
|
131 |
|
|
87 |
|
|
114 |
|
| CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL CONDITIONS PRIOR TO |
| SUBMITTING SHOP DRAWINGS. |
| CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH DISCOVERIES |
| IN THE CONSTRUCTION SCHEDULE. |
| CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301 |
-9 |
9, SPECIFICATIONS FOR STRUCTURAL |
| UNLESS OTHERWISE DETAILED OR NOTED, REINFORCING SHALL BE IN ACCORDANCE WITH "THE ACI DETAILING MANUA |
|
|
| SP |
- |
66." |
| TYPICAL DETAILS. DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC |
| DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE ON THE PROJECT |
| SHOP DRAWINGS WILL BE FOR COMPLIANCE WITH DESIGN REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR |
| VERIFYING DIMENSIONS AND QUANTITIES RELATIVE TO REINFORCING STEEL. |
| LICENSED TO PRACTICE IN THE STATE OF ILLINOIS. THE TESTING AGENCY SHALL MEET REQUIREMENTS CONTAINED IN AST |
| E329. SEE SPECIFICATIONS FOR TESTING REQUIREMENTS. |
| LAP LENGTHS ASSUME CLEAR SPACING BETWEEN BARS OF 2 BAR DIAMETERS, AND A MINIMUM |
|
| COVER OF 1 BAR DIAMETER. FOR DEVELOPMENT LENGTHS, DIVIDE BY 1.3. TOP BARS ARE DEFINED AS |
|
| HORIZONTAL BARS WITH MORE THAN 1'- |
0" OF FRESH CONCRETE BELOW. |
| THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS |
| RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE |
| REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES |
| SUBMIT SHOP DRAWINGS SHOWING REINFORCING STEEL QUANTITIES AND PLACEMENT. REINFORCING STEEL |
|
|
| DESIGNATIONS ON SHOP DRAWINGS SHALL BE INCH |
- |
POUND SIZES. |
| CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER |
| THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION |
| PERIOD. |
| TRIAL BATCH METHOD: IF TRIAL BATCHES ARE USED, AND INDEPENDENT TESTING LABORATORY, APPROVED BY |
| THE ARCHITECT, SHALL PREPARE MIX DESIGNS. THE MIX DESIGN SHALL BE PROPORTIONED TO ACHIEVE A |
| AVERAGE STRENGTH OF 1200 PSI HIGHER THAN THE SPECIFIED STRENGTH (F'C). |
| ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE AMERICAN CONCRETE |
| INSTITUTE "DETAILS AND DETAILING OF REINFORCED CONCRETE" (ACI 315) EXCEPT AS OTHERWISE SHOWN, NOTED OR |
| SPECIFIED |
| FIELD EXPERIENCE METHOD: IF THE FIELD EXPERIENCE METHOD IS SELECTED, THE PROPOSED MIX DESIG |
| MUST BE ACCOMPANIED BY THE COMPLETE STANDARD DEVIATION ANALYSIS |
| SUBMITTALS: |
|
| 1)IF THE CONTRACTOR REQUESTS A CHANGE FROM THE STRUCTURAL DRAWINGS, IT SHALL BE |
|
|
APPROVED AND DESIGNED BY THE ENGINEER OF RECORD PRIOR TO SUBMITTING SHOP DRAWINGS |
|
VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS. THE CONTRACTOR SHALL COMPENSATE |
|
CARR ENGINEERING, LLC FOR CHANGES. |
| PROVIDE ADEQUATE TIES FOR ALL REINFORCING BARS AND STIRRUPS IN CONCRETE SLABS AND BEAMS. REINFORCING |
| BARS TO BE HELD AT CORRECT DISTANCE FROM FORMS BY ADEQUATE CONCRETE BLOCKS, STEEL CHAIRS OR TIES. ALL |
| REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE SECURED IN POSITION WITH TIES OR |
| WELDS PRIOR TO PLACING CONCRETE. |
| READY- |
MIX CONCRETE SHALL BE IN COMPLIANCE WITH REQUIREMENTS OF ASTM C94, AND AS HEREIN SPECIFIED. |
| UNLESS NOTED OTHERWISE, SUPPORTS FOR REINFORCEMENT SHALL HAVE CLASS 2 PROTECTION AS DEFINED IN THE |
| CRSI MANUAL OF STANDARD PRACTICE. |
| TYPE |
INTENDED
USE |
28 DAY MAX
STRENGTH |
MAX WATER/CEMENT
RATIO INCLUDING
FLY ASH |
MIN CEMENT
MATERIAL
INCLUDING
FLY ASH |
MAX AGGREGATE
SIZE |
CEMENT TYPE |
SLUMP LIMITS
( +1", -2" ) |
| 1 |
SLAB-ON
-GRADE |
4 KSI |
0.50 |
520 LB/CU. YD |
3/4 IN |
I OR II |
4 |
| 2 |
FOOTINGS
GRADE BEAMS
AND WALLS |
4 KSI |
0.50 |
520 LB/CU. YD |
1 IN |
I OR II |
4 |
| SUPPORTS FOR COATED REINFORCEMENT SHALL HAVE CLASS 1 PROTECTION AS DEFINED IN THE CRSI MANUAL OF |
| STANDARD PRACTICE. |
| NON |
- |
CONFORMANCE: NOTIFY ENGINEER OF CONDITIONS NOT CONSTRUCTED PER CONTRACT |
| DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE |
|
|
| ENGINEER FOR ACCEPTANCE. CONTRACTOR SHALL COMPENSATE CARR ENGINEERING, LLC FOR |
|
|
| DESIGN OF THE REPAIR. |
|
|
| CONTINUOUS REINFORCING SHALL BE LAPPED AS FOLLOWS UNLESS NOTED OTHERWISE: |
| TOP BARS |
| BOTTOM BARS |
| THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. NOTHING SHOWN ON THE |
| STRUCTURAL DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR T |
| COMPLY WITH ALL OSHA REQUIREMENTS. THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR |
| BOLTS, STIFFENER PLATES, STABILIZER PLATES, BRIDGING, BRACING, BEARING SEATS, COLUMN SPLICES |
| ETC., AS WELL AS CLOSURES FOR OPENINGS. |
| REINFORCING BARS SHALL BE BENT COLD, AND NO METHOD OF FABRICATION SHALL BE USED WHICH WOULD BE |
| INJURIOUS TO THE MATERIAL. HEATING OF BARS FOR BENDING IS NOT PERMITTED. |
| WASHERS OR RINGS SHALL BE WELDED TO STEEL COLUMNS TO PROVIDE FOR SAFETY CABLES, DO NOT |
| PLACE HOLES IN COLUMNS WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER. |
| WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL |
| DRAWINGS REPRESENT FINAL CONDITIONS ONLY; THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING |
| THAT MAY BE NECESSARY TO COMPLY WITH OSHA. |
| THE STRUCTURE DEFINED IN THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY FOR LOADS ANTICIPATED |
| ON THE STRUCTURE DURING ITS SERVICE LIFE. PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO |
| -
-
- |
|
| -
- |
|
| - |
DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND, SEISMIC, OR SOIL LOADS. |
| - |
|
| -
- |
|
|
|
3 D W 2/3 D |
|
|
|
|
|
|
|
|
|
|
|
|
|
TRUCTURAL
D LL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OF ILLIN
ATE
O
S T IS
CHAD M.
L CARR R
E
IC 081-006490 E
E N
N I
S G
E N
D E
STRUCTURA L |
I hereby certify that this engineering document was prepared by
me or under my direct personal supervision and that I am a duly
licensed Structural Engineer under the laws of the State of
Illinois.
11-04-2025
Signature Date
Chad M. Carr
License No. 081-006490
My license renewal date is November 30, 2026
Pages or sheets covered by this seal: S100 -S301
Carr Engineering LLC
Illinois Design Firm License: #184.007877-0003 |
DESIGN LOAD CRITERIA: 9. COORDINATION: METAL BUILDING CRITERIA:
1. AS REQUIRED BY ROCK ISLAND COUNTY, IL, ENGINEERING DESIGN IS BASED ON AND ACCORDANCE
A. STRUCTURAL DRAWINGS RE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN
WITH THE FOLLOWING CODE(S): 1. FOUNDATION DESIGN IS BASED ON PRELIMINARY DESIGN DRAWINGS RECEIVED FROM BUTLER MANUFACTURING. FINAL
CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER
DESIGN REACTIONS SUPPLIED BY THE SELECTED METAL BUILDING MANUFACTURER MAY DIFFER FROM PRELIMINARY
DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS
A. INTERNATIONAL BUILDING CODE -2012 ESTIMATED REACTIONS. BASED ON FINAL REACTIONS SUPPLIED, MODIFICATIONS TO THE FOUNDATION PLAN MAY BE
INTO SHOP DRAWINGS AND WORK.
REQUIRED. GENERAL CONTRACTOR SHALL INCLUDE IN THEIR BID AN ADD AND DEDUCT PRICE PER CUBIC YARD OF
2. DESIGN LOADS:
CONCRETE WORK INSTALLED IN CASE SUCH CHANGES ARE REQUIRED.
B. COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS, DEPRESSIONS, ETC. WITH DRAWINGS FROM OTHER
A. SUPERIMPOSED ROOF DEAD LOAD ................................... BY METAL BUILDING MNFR. DISCIPLINES, PROJECT SHOP DRAWINGS, AND FIELD CONDITIONS PRIOR TO SHOP DRAWINGS SUBMITTAL.
2. METAL BUILDING MANUFACTURER SHALL ENGAGE A PROFESSIONAL ENGINEER LICENSED TO PRACTICE STRUCTURAL
FLOOR LIVE LOAD .................................................................. 250 PSF
ENGINEERING IN THE STATE OF ILLINOIS TO DESIGN THE METAL BUILDING AND TO SUBMIT STAMPED AND SEALED
10. SPECIAL INSPECTION:
DRAWINGS AND STRUCTURAL CALCULATIONS FOR THE METAL BUILDING.
B. SNOW LOAD:
1) GROUND SNOW LOAD (Pg) .............................................. 20 PSF A. SPECIAL INSPECTION SHALL BE PROVIDED PER IBC 2012 CHAPTER 17. THE LIST BELOW IS A SUMMARY OF ITEMS 3. FOUNDATION DESIGN IS BASED ON THE METAL BUILDING COLUMNS HAVING PINNED BASES AND TRANSFERRING NO
2) SNOW EXPOSURE FACTOR (Ce) ..................................... 1.0 REQUIRING INSPECTION BY THE IBC:
MOMENTS TO THE FOUNDATIONS.
3) SNOW IMPORTANCE FACTOR ......................................... 1.00
4) THERMAL FACTOR (Ct) ..................................................... 1.0 SEE TABLE ON SHEET S101
4. ALL EXTERNAL LATERAL LOAD RESISTANCE AND STABILITY OF THE METAL BUILDING IN THE COMPLETED STRUCTURE IS
PROVIDED BY MOMENT FRAMES AND TENSION ONLY ROD BRACING. THE VERTICAL LATERAL MEMBERS CARRY THE
C. WIND LOAD:
APPLIED LATERAL LOADS TO THE BUILDING FOUNDATION. THE TENSION ONLY ROD BRACING AT THE ROOF SERVES AS THE
1) BASIC WIND SPEED (3 SEC GUST) ................................. 115 MPH
HORIZONTAL DIAPHRAGM THAT DISTRIBUTES THE LATERAL WIND AND SEISMIC FORCES HORIZONTALLY TO THE VERTICAL
2) WIND IMPORTANCE FACTOR ...........................................1.0
LATERAL MEMBERS. ALL LATERAL RESISTING MEMBERS ARE BY THE METAL BUILDING MANUFACTURER.
3) BUILDING CATEGORY ....................................................... II EARTHWORK NOTES:
4) WIND EXPOSURE ............................................................... C
1. REFER TO ARCHITECTURAL DRAWINGS FOR BUILDING LOCATION ON THE SITE, FLOOR ELEVATION AND OTHER PERTINENT 5. METAL BUILDING MANUFACTURER IS SOLELY RESPONSIBLE FOR THE DESIGN AND MANUFACTURER OF THE METAL
5) INTERNAL PRESSURE COEFFICIENT .............................. 0.18
SITE AND BUILDING INFORMATION. BUILDING. THE BUILDING MUST BE DESIGNED TO MEET THE LOADING INDICATED IN THE DRAWINGS AND THE DESIGN
CRITERIA INDICATED ABOVE.
D. SEISMIC:
2. ELEVATIONS GIVEN THUS ARE TO THE TOP OF FOOTINGS, SLABS, BEAMS, JOISTS, ETC. WITH REFERENCE TO THE
1) SEISMIC DESIGN CATEGORY ........................................... B
FINISHED FLOOR ELEVATION = (0'-0"). 6. METAL BUILDING MANUFACTURER IS TO COORDINATE WITH ARCHITECTURAL DRAWINGS FOR WINDOW AND DOOR
2) SEISMIC IMPORTANCE FACTOR ...................................... 1.00
OPENINGS WHEN DESIGNING THE LATERAL SYSTEM.
3)SPECTRAL RESPONSE COEFFICIENTS 3. A GEOTECHNICAL REPORT IS NOT AVAILABLE FOR THIS SITE. ADDITIONAL TEST BORINGS AND OTHER EXPLORATORY
Ss .......................................................................................... 0.19 OPERATIONS MAY BE MADE BY THE CONTRACTOR WITH APPROVAL FROM THE OWNER. DESIGN VALUES FROM THE 2012 IBC 7. SEE METAL BUILDING DRAWINGS FOR ANCHOR ROD MATERIAL GRADE, ANCHOR ROD DIAMETERS, QUANTITIES AND
S1 .......................................................................................... 0.085 ARE AS FOLLOWS: LAYOUT.
4) SITE CLASS ......................................................................... D
5)BASIC SEISMIC FORCE RESISTING SYSTEMS DESCRIPTION: A. ALLOWABLE SOIL BEARING FOR FOOTING .................................................................................................................. 2500 PSF
STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION FACTOR (R) USED ................3.0 B. MINIMUM SOIL SUBGRADE MODULUS REQUIRED ....................................................................................................... 125 PCI
REINFORCEMENT STEEL:
4. THE TOP 9" (MIN.) OF THE EXISTING GRADE IS TO BE SCARIFIED AND RECOMPACTED TO MEET OR EXCEED THE REQUIREMENT 1. FOR CAST-IN-PLACE CONCRETE THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR
GIVEN IN THE GEOTECHNICAL REPORT. REINFORCEMENT UNLESS NOTED OTHERWISE:
GENERAL REQUIREMENTS:
5. UNLESS NOTED OTHERWISE, NEW FOOTINGS SHALL CENTER UNDER THE WALLS, PIERS OR COLUMNS. CONCRETE CAST AGAINST AND
1. DEFINITIONS:
PERMANENTLY EXPOSED TO EARTH 3 INCHES
A. ENGINEER: REFERENCES OF THE STRUCTURAL DRAWINGS TO 'ENGINEER' MEAN THE 6. WATER SHALL NOT BE ALLOWED TO ACCUMULATE IN THE EXCAVATION. PROVIDE PUMPS, IF NECESSARY, AND OPERATE
CONCRETE EXPOSED TO EARTH OR WEATHER
STRUCTURAL ENGINEER OF RECORD. OTHER ENTITIES ARE SPECIFICALLY NOTED AS NIGHT AND DAY, WHENEVER REQUIRED.
NO. 6 BARS OR LARGER 2 INCHES
"CONTRACTORS ENGINEER", "MECHANICAL ENGINEER", ETC.
NO. 5 BARS OR SMALLER 1 1/2 INCHES
7. THE BASE OF ALL FOOTING EXCAVATIONS SHALL BE OBSERVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT
2. UNDERGROUND UTILITIES: LOCATE EXISTING UTILITIES, AND NOTIFY ENGINEER OF EXISTING OF CONCRETE.
SLABS, WALLS, JOISTS NOT EXPOSED
UTILITIES OR SUBGRADE CONDITIONS WHICH INTERFERE WITH WORK.
8. BACKFILL PLACED WITHIN THE BUILDING AREA SHALL BE WITH SOIL THAT IS APPROVED BY THE GEOTECHNICAL ENGINEER. TO WEATHER OR IN CONTACT WITH EARTH
NO. 14 AND NO. 18 BARS 1 1/2 INCHES
3. EXISTING STRUCTURES: PLACE IN LIFTS AND COMPACT IN STRICT COMPLIANCE WITH RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER.
NO. 11 BARS OR SMALLER 3/4 INCHES
PLACE IN LOOSE LIFTS OF 8 INCHES OR LESS AND COMPACT. FILL SHOULD BE FREE OF FAT CLAYS AND ORGANIC SOIL
A. CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS (UNIFIED SOIL CLASSIFICATIONS CH, OL, OH, MH OR PT), FROZEN MATERIAL, RUBBLE, DEGRADABLE MATERIAL, CHEMICAL
BEAMS AND COLUMNS NOT EXPOSED TO
AND SITE OBSERVATION AS PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN. CONTAMINANTS AND STONES THAT INTERFERE WITH COMPACTION OR COMPACTION TESTING. IN GENERAL, AT LEAST 70%
WEATHER OR IN CONTACT WITH EARTH 1 1/2 INCHES
OF THE FILL SHOULD PASS A 3/4-INCH SIEVE, THE OVER-SIZE LIMIT FOR THE ASTM D698 MAXIMUM DENSITY TEST.
B. DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS
WHICH ARE NOT NOW KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION 9. FILL SHOULD BE PLACES ON STABLE, UNFROZEN SURFACES AND IN NEARLY HORIZONTAL LIFTS THAT HAVE THICKNESSES 2. DIMENSIONS OF CONCRETE COVER FOR REINFORCEMENT INDICATED ON DRAWINGS ARE TO OUTERMOST
THAT ARE COMPATIBLE WITH THE COMPACTION EQUIPMENT USED, BUT GENERALLY NOT OVER EIGHT INCHES. ALL FILL REINFORCING BARS. FOR BEAMS OR COLUMNS WITH STIRRUPS OR TIES, CLEAR COVER INDICATED IS TO STIRRUPS OR
(DISCOVERY). CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CONDITIONS NOT
OTHER THAN COARSE AGGREGATES SHOULD BE COMPACTED TO AT LEAST 95% OF ITS MAXIMUM DRY DENSITY TIES.
PER THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE:
DETERMINED BY ASTM D698, TEST METHOD FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD
-SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN.
EFFORT (12,400 FT-LB/CUBIC FOOT). COMPACTION USUALLY REQUIRES ADJUSTMENTS OF FILL MOISTURE CONTENTS TO 3. BAR SPLICES: SPLICE REINFORCING WHERE INDICATED ON THE DRAWINGS. ALL SPLICES SHALL BE CLASS 'B' AS
-DAMAGE OR DETERIORATION TO MATERIALS OR COMPONENTS.
WITHIN THREE PERCENTAGE POINTS OF THE ASTM D698 OPTIMUM MOISTURE. COARSE AGGREGATES SHOULD BE DEFINED IN ACI 318. IF SPLICE LENGTH IS NOT GIVEN ON THE DRAWINGS, PROVIDE LAP LENGTHS (IN INCHES) AS
-ITEMS NOTED AS EXISTING ON THE DRAWINGS BUT NOT FOUND IN THE FIELD.
VIBRATORY-COMPACTED TO INTERLOCK THE PARTICLES TO 98% STANDARD PROCTOR PER ASTM D698. FOLLOWS:
C. PREPARE DIMENSIONAL DRAWINGS OF ALL DISCOVERED ITEMS.
3000 PSI CONC 4000 PSI CONC
D. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL CONDITIONS PRIOR TO
SUBMITTING SHOP DRAWINGS. BAR SIZE OTHER TOP OTHER TOP
CONCRETE NOTES:
E. CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH DISCOVERIES #3 22 28 19 25
1. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301-99, SPECIFICATIONS FOR STRUCTURAL
IN THE CONSTRUCTION SCHEDULE.
#4 29 38 25 33
CONCRETE FOR BUILDINGS, EXCEPT AS MODIFIED BY SUPPLEMENTAL REQUIREMENTS CONTAINED IN THE FOLLOWING
4. USE OF DRAWINGS: NOTES. #5 36 47 31 41
#6 43 56 37 49
2. UNLESS OTHERWISE DETAILED OR NOTED, REINFORCING SHALL BE IN ACCORDANCE WITH "THE ACI DETAILING MANUAL,
A. DO NOT SCALE DRAWINGS.
SP-66." #7 63 81 54 71
B. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS AND GENERAL NOTES, THE MORE STRINGENT #8 72 93 62 81
3. SUBMIT SHOP DRAWINGS FOR FABRICATION AND PLACEMENT OF CONCRETE REINFORCING. SHOW PLAN VIEW OF SLAB, INCLUDE
REQUIREMENTS SHALL GOVERN. DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND SCHEDULES AND DIAGRAMS OF BENT BARS AND SHOW ARRANGEMENT OF CONCRETE REINFORCING. ENGINEER'S REVIEW OF #9 81 105 70 91
TYPICAL DETAILS. DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC
SHOP DRAWINGS WILL BE FOR COMPLIANCE WITH DESIGN REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR #10 91 118 79 102
DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE ON THE PROJECT.
VERIFYING DIMENSIONS AND QUANTITIES RELATIVE TO REINFORCING STEEL. #11 101 131 87 114
4. ALL CONCRETE TESTING SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A QUALIFIED ENGINEER WHO IS
5. TEMPORARY CONDITIONS:
LICENSED TO PRACTICE IN THE STATE OF ILLINOIS. THE TESTING AGENCY SHALL MEET REQUIREMENTS CONTAINED IN ASTM
LAP LENGTHS ASSUME CLEAR SPACING BETWEEN BARS OF 2 BAR DIAMETERS, AND A MINIMUM
E329. SEE SPECIFICATIONS FOR TESTING REQUIREMENTS.
A. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS COVER OF 1 BAR DIAMETER. FOR DEVELOPMENT LENGTHS, DIVIDE BY 1.3. TOP BARS ARE DEFINED AS
RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE HORIZONTAL BARS WITH MORE THAN 1'-0" OF FRESH CONCRETE BELOW.
5. PREPARE DESIGN MIXES FOR EACH TYPE AND STRENGTH OF CONCRETE BY EITHER LABORATORY TRIAL BATCH OR FIELD
REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES.
EXPERIENCE METHODS AS SPECIFIED IN ACI 301.
4. SUBMIT SHOP DRAWINGS SHOWING REINFORCING STEEL QUANTITIES AND PLACEMENT. REINFORCING STEEL
B. CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER DESIGNATIONS ON SHOP DRAWINGS SHALL BE INCH-POUND SIZES.
A. TRIAL BATCH METHOD: IF TRIAL BATCHES ARE USED, AND INDEPENDENT TESTING LABORATORY, APPROVED BY
THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION
THE ARCHITECT, SHALL PREPARE MIX DESIGNS. THE MIX DESIGN SHALL BE PROPORTIONED TO ACHIEVE AN
PERIOD. 5. ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE AMERICAN CONCRETE
AVERAGE STRENGTH OF 1200 PSI HIGHER THAN THE SPECIFIED STRENGTH (F'C).
INSTITUTE "DETAILS AND DETAILING OF REINFORCED CONCRETE" (ACI 315) EXCEPT AS OTHERWISE SHOWN, NOTED OR 6. SUBMITTALS AND SUBSTITUTIONS: SPECIFIED.
B. FIELD EXPERIENCE METHOD: IF THE FIELD EXPERIENCE METHOD IS SELECTED, THE PROPOSED MIX DESIGN
A. SUBMITTALS: MUST BE ACCOMPANIED BY THE COMPLETE STANDARD DEVIATION ANALYSIS.
6. PROVIDE ADEQUATE TIES FOR ALL REINFORCING BARS AND STIRRUPS IN CONCRETE SLABS AND BEAMS. REINFORCING
1)IF THE CONTRACTOR REQUESTS A CHANGE FROM THE STRUCTURAL DRAWINGS, IT SHALL BE
BARS TO BE HELD AT CORRECT DISTANCE FROM FORMS BY ADEQUATE CONCRETE BLOCKS, STEEL CHAIRS OR TIES. ALL
APPROVED AND DESIGNED BY THE ENGINEER OF RECORD PRIOR TO SUBMITTING SHOP DRAWINGS. C. SLUMP SHALL BE 4" MAXIMUM, 2" MINIMUM FOR STRUCTURAL SLABS.
REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE SECURED IN POSITION WITH TIES OR
VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS. THE CONTRACTOR SHALL COMPENSATE
6. READY-MIX CONCRETE SHALL BE IN COMPLIANCE WITH REQUIREMENTS OF ASTM C94, AND AS HEREIN SPECIFIED. WELDS PRIOR TO PLACING CONCRETE.
CARR ENGINEERING, LLC FOR CHANGES.
7. COMPRESSIVE STRENGTH: STRENGTH REQUIREMENTS AT 28 DAYS AND THE LOCATION OF EACH TYPE OF CONCRETE 7. UNLESS NOTED OTHERWISE, SUPPORTS FOR REINFORCEMENT SHALL HAVE CLASS 2 PROTECTION AS DEFINED IN THE
2)CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR USE IN SUBMITTALS.
REQUIRED FOR THIS PROJECT SHALL BE AS FALLOWS: CRSI MANUAL OF STANDARD PRACTICE.
B. SUBSTITUTIONS: ENGINEER'S APPROVAL SHALL BE SECURED FOR ALL SUBSTITUTIONS. MIN CEMENT 8. SUPPORTS FOR COATED REINFORCEMENT SHALL HAVE CLASS 1 PROTECTION AS DEFINED IN THE CRSI MANUAL OF
MAX WATER/CEMENT
INTENDED 28 DAY MAX MATERIAL MAX AGGREGATE SLUMP LIMITS STANDARD PRACTICE.
C. NON-CONFORMANCE: NOTIFY ENGINEER OF CONDITIONS NOT CONSTRUCTED PER CONTRACT TYPE RATIO INCLUDING CEMENT TYPE
USE STRENGTH INCLUDING SIZE ( +1", -2" )
DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE FLY ASH FLY ASH 9. CONTINUOUS REINFORCING SHALL BE LAPPED AS FOLLOWS UNLESS NOTED OTHERWISE:
ENGINEER FOR ACCEPTANCE. CONTRACTOR SHALL COMPENSATE CARR ENGINEERING, LLC FOR
TOP BARS MIDSPAN
DESIGN OF THE REPAIR.
SLAB-ON BOTTOM BARS DIRECTLY OVER SUPPORT
7. OSHA STANDARDS: 1 -GRADE 4 KSI 0.50 520 LB/CU. YD 3/4 IN I OR II 4
10. DOWELS BETWEEN FOOTINGS AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING OR NUMBER AS
A. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. NOTHING SHOWN ON THE THE VERTICAL REINFORCING, RESPECTIVELY, UNLESS NOTED OTHERWISE. FOOTINGS
STRUCTURAL DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR TO
2 GRADE BEAMS 4 KSI 0.50 520 LB/CU. YD 1 IN I OR II 4
COMPLY WITH ALL OSHA REQUIREMENTS. THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR 11. REINFORCING BARS SHALL BE BENT COLD, AND NO METHOD OF FABRICATION SHALL BE USED WHICH WOULD BE
AND WALLS
BOLTS, STIFFENER PLATES, STABILIZER PLATES, BRIDGING, BRACING, BEARING SEATS, COLUMN SPLICES INJURIOUS TO THE MATERIAL. HEATING OF BARS FOR BENDING IS NOT PERMITTED.
ETC., AS WELL AS CLOSURES FOR OPENINGS.
B. WASHERS OR RINGS SHALL BE WELDED TO STEEL COLUMNS TO PROVIDE FOR SAFETY CABLES, DO NOT
PLACE HOLES IN COLUMNS WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER.
C. WHERE THE STRUCTURAL DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL
DRAWINGS REPRESENT FINAL CONDITIONS ONLY; THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING
THAT MAY BE NECESSARY TO COMPLY WITH OSHA.
8. CONSTRUCTION ENGINEERING:
THE STRUCTURE DEFINED IN THE CONTRACT DOCUMENTS HAS BEEN DESIGNED ONLY FOR LOADS ANTICIPATED
ON THE STRUCTURE DURING ITS SERVICE LIFE. PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO
ACHIEVE THE MEANS, METHODS AND SEQUENCES OF WORK. SUCH ENGINEERING MAY INCLUDE, BUT IS NOT LIMITED
TO:
-LAYOUT. 2/3 D W 2/3 D
-DESIGN OF FORMWORK, SHORING AND RESHORING.
-DESIGN OF CONCRETE MIXES.
-ERECTION PROCEDURES WHICH ADDRESS STABILITY OF THE FRAME DURING CONSTRUCTION OF STEEL.
-WELD PROCEDURES.
-DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND, SEISMIC, OR SOIL LOADS.
-SURVEYING TO VERIFY CONSTRUCTION TOLERANCES.
-EVALUATION OF TEMPORARY LOADS ON STRUCTURE DUE TO EQUIPMENT AND MATERIALS DURING CONSTRUCTION.
-STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS NOT IDENTIFIED ON DESIGN DRAWINGS.
D
Project number
Date
DESIGN FTG LEVEL Drawn by
Checked by
STRUCTURAL I hereby certify that this engineering document was prepared by
FILL me or under my direct personal supervision and that I am a duly
RECOMMENDED
licensed Structural Engineer under the laws of the State of EXCAVATION LEVEL
ATE
OF ILLIN
O
Illinois.
S T IS 11-04-2025
Signature Date
CHAD M.
L CARR R
IC 081-006490 E E Chad M. Carr E N License No. 081-006490
N I
S E N G My license renewal date is November 30, 2026 D E
STRUCTURA L Pages or sheets covered by this seal: S100 -S301
Carr Engineering LLC
Illinois Design Firm License: #184.007877-0003
4202
(C)
THGIRYPOC
CARR ENGINEERING, LLC
ILLINOIS DESIGN FIRM LIC No.
184.007877-0003
3294 Fields Dr.
Bettendorf, IA 52722
(563) 503-6100
MP
73:60:5
6202/9/3
25-134
GENERAL NOTES
S100
TROPRIA
LANOITANRETNI
YTIC
DAUQ
YTIROHTUA
TROPRIA
NATILOPORTEM
.OC
DNALSI
KCOR
11/04/2025
WDH
CMC
GNIDLIUB
RAGNAH
KRIK
SIONILLI
,ENILOM
SCHEDULE E
NO. DESCRIPTION DATE
1 PERMIT SET 11.04.25
TYP FOOTING OVER EXCAVATION 1
3/4" = 1'-0"
| STRUCTURAL COMPONENT TESTING AND INSPECTION
1. THE FOLLOWING TESTING AND INSPECTION OF STRUCTURAL COMPONENTS IS REQUIRED AS DETAILED IN CHAPTER 17 OF THE 2012 INTERNATIONALBUILDING CODE (IBC).
2. SEE MECHANICAL, PLUMBING AND ELECTRICAL SPECIFICATIONS FOR TESTING AND INSPECTION REQUIREMENTS OF NON-STRUCTURAL COMPONENTS.
3. WORK PERFORMED ON THE PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL PER SECTION 1704.2.5.1 OF CHAPTER 17 OF THE 2012 INTERNATIONAL BUILDING
CODE NEED NOT BE TESTED AND INSPECTED PER THE TABLE BELOW. THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE THAT THE WORK HAS BEEN PERFORMED IN
ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS TO THE BUILDING OFFICIAL AND THE ARCHITECT AND ENGINEER OF RECORD.
4. DUTIES OF THE SPECIAL INSPECTION AGENCY (IBC CHAPTER 17):
A. PERFORM ALL TESTING AND INSPECTION REQUIRED PER APPROVED TESTING AND INSPECTION PROGRAM.
B. FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND THE OWNER.
C. SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTIONAGENCY'S KNOWLEDGE,
IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. |
|
|
|
|
|
|
|
|
|
|
|
|
|
SUOUNITNOC |
CIDOIREP |
|
|
REFERENCE
D STANDARD |
IBC
REFERENCE |
|
|
| FOUNDATION PREPARATION |
|
|
|
|
|
|
|
|
|
|
| VERIFY MATERIALS BELOW SHALLOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. |
|
|
|
X |
|
|
|
1705.6 |
|
|
| VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. |
|
|
|
X |
|
|
|
1705.6 |
|
|
|
PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS. |
|
|
|
X |
|
|
|
1705.6 |
|
| VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. |
|
|
X |
|
|
|
|
1705.6 |
|
|
| PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT THE SITE HAVE BEEN PROPERLY PREPARED. |
|
|
|
X |
|
|
|
1705.6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONCRETE AND CONCRETE PLACEMENT |
|
|
|
|
|
|
|
|
|
|
| INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. |
|
|
|
X |
|
|
ACI 318: 26.11.1.2(b) |
|
|
|
| INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. |
|
|
|
X |
|
|
ACI 318: CHG. 20, 25.2, 25.3,
26.6.1-26.6.3 |
1908.4 |
|
|
| INSPECTION OF ANCHORS POST-INSTALLED INSTALLED IN HARDENED CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARD INCLINED ORIENTATIONS TO RESIST SUSTAINED LOADS. |
|
|
X |
|
|
|
ACI 318: 17.8.2.4(b) |
|
|
|
| VERIFYING USE OF REQUIRED DESIGN MIX. |
|
|
|
X |
|
|
ACI 318: CH. 19, 26.4.3, 26.4.4 |
1904.1, 1904.2
1908.2, 1908.3 |
|
|
| PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE. |
|
|
X |
|
|
|
ACI 318: 26.4, 26.12 |
1908.10 |
|
|
| INSPECTION OF CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. |
|
|
X |
|
|
|
ACI 318: 26.5 |
|
1908.6, 1908.7, |
|
|
|
|
|
|
|
|
|
|
1908.8 |
|
| F AND F SLAB ON GRADE FLATNESS TESTING
F L |
|
|
|
|
|
|
ASTM E1155 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| STRUCTURAL STEEL |
|
|
|
|
|
|
REFERENCE
D STANDARD |
IBC
REFERENCE |
|
|
| 1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS, AND WASHERS:
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.
B. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. |
|
|
|
X
X |
|
|
APPLICABLE ASTM MATERIAL
STANDARDS: AISC 360,
SECTION A3.3 |
|
|
|
| 2. INSPECTION OF HIGH-STRENGTH BOLTING:
A. SNUG TIGHT JOINTS. |
|
|
|
X |
|
|
AISC 360, SECTION M2.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| STEEL DECK |
|
|
|
|
|
|
REFERENCE
D STANDARD |
IBC
REFERENCE |
|
|
| 1. MATERIAL VERIFICATION OF STRUCTURAL STEEL
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS.
B. MANUFACTURER'S CERTIFIED TEST REPORTS. |
|
|
|
X
X |
|
|
APPLICABLE ASTM
MATERIAL STANDARDS |
|
|
|
| 2. INSPECTION OF WELDING:
A. FLOOR AND ROOF DECK WELDS. |
|
|
|
X |
|
|
AW D1.3 |
|
|
|
| THE FOLLOWING TESTING AND INSPECTION OF STRUCTURAL COMPONENTS IS REQUIRED AS DETAILED IN CHAPTER 17 OF THE 2012 INTERNATIONAL |
BUILDING CODE (IBC). |
| SEE MECHANICAL, PLUMBING AND ELECTRICAL SPECIFICATIONS FOR TESTING AND INSPECTION REQUIREMENTS OF NON |
- |
STRUCTURAL COMPONENTS. |
| WORK PERFORMED ON THE PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL PER SECTION 1704.2.5.1 OF CHAPTER 17 OF THE |
2012 INTERNATIONAL BUILDING |
|
| CODE NEED NOT BE TESTED AND INSPECTED PER THE TABLE BELOW. THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE THAT THE |
|
WORK HAS BEEN PERFORMED IN |
| ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS TO THE BUILDING OFFICIAL AND THE ARCHITECT AND ENGINEER OF RECORD. |
|
|
| CARR ENGINEERING, LLC |
|
|
| ILLINOIS DESIGN FIRM LIC No. |
|
|
| 184.007877 |
- |
0003 |
| 3294 Fields Dr. |
|
|
| Bettendorf, IA 52722 |
|
|
| (563) 503 |
- |
6100 |
| SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTION |
AGENCY'S KNOWLEDGE, |
| IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS. |
|
| ACI 318: CHG. 20, 25.2, 25.3, |
|
|
| 26.6.1 |
- |
26.6.3 |
| INSPECTION OF ANCHORS POST |
- |
INSTALLED INSTALLED IN HARDENED CONCRETE MEMBERS. |
|
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARD INCLINED ORIENTATIONS TO RESIST SUSTAINED LOADS. |
| PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND |
| DETERMINE THE TEMPERATURE OF THE CONCRETE. |
| F
F |
AND F |
L |
SLAB ON GRADE FLATNESS TESTING |
| APPLICABLE ASTM MATERIAL |
| STANDARDS: AISC 360, |
| SECTION A3.3 |
| B. MANUFACTURER |
'S CERTIFICATE OF COMPLIANCE REQUIRED. |
| 2. INSPECTION OF HIGH- |
STRENGTH BOLTING: |
| A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. |
|
| B. MANUFACTURER |
'S CERTIFIED TEST REPORTS. |
| APPLICABLE ASTM |
| MATERIAL STANDARDS |
| SYMBOLS LEGEND |
| DESCRIPTION SYMBOL DESCRIPTION SYMBOL
T/X
STEP UP = ELEVATION =
EL (XXX'-X")
SLOPE UP = REVISION CLOUD =
MOMENT
NORTH ARROW =
CONNECTION =
N H
OR T
DETAIL DTL#
SECTION CUT =
GRADE = SHT#
STRUCTURAL FILL =
#LTD #THS
BUILDING
SECTION CUT =
SUBGRADE =
CONCRETE
IN SECTION =
BRACE =
MASONRY =
FOOTING SIZE = F-X WELDED WIRE FABRIC =
(-X'-X")
COLUMN = C-X
FOOTING STEP =
(-X'-X") |
STRUCTURAL COMPONENT TESTING AND INSPECTION
1.
2. SEE MECHANICAL, PLUMBING AND ELECTRICAL SPECIFICATIONS FOR TESTING AND INSPECTION REQUIREMENTS OF NON-STRUCTURAL COMPONENTS.
FOUNDATION PREPARATION
VERIFY MATERIALS BELOW SHALLOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY. X
VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. X
PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
X
CONCRETE AND CONCRETE PLACEMENT
INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT. X
STRUCTURAL STEEL
SUOUNITNOC
THE FOLLOWING TESTING AND INSPECTION OF STRUCTURAL COMPONENTS IS REQUIRED AS DETAILED IN CHAPTER 17 OF THE 2012 INTERNATIONALBUILDING CODE (IBC).
4. DUTIES OF THE SPECIAL INSPECTION AGENCY (IBC CHAPTER 17):
A. PERFORM ALL TESTING AND INSPECTION REQUIRED PER APPROVED TESTING AND INSPECTION PROGRAM.
B. FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND THE OWNER.
C. SUBMIT A FINAL SIGNED REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTIONAGENCY'S KNOWLEDGE,
IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS.
CIDOIREP
3. WORK PERFORMED ON THE PREMISES OF A FABRICATOR APPROVED BY THE BUILDING OFFICIAL PER SECTION 1704.2.5.1 OF CHAPTER 17 OF THE 2012 INTERNATIONAL BUILDING
CODE NEED NOT BE TESTED AND INSPECTED PER THE TABLE BELOW. THE FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE THAT THE WORK HAS BEEN PERFORMED IN
ACCORDANCE WITH THE APPROVED PLANS AND SPECIFICATIONS TO THE BUILDING OFFICIAL AND THE ARCHITECT AND ENGINEER OF RECORD.
REFERENCE IBC
D STANDARD REFERENCE
1705.6
1705.6
X 1705.6
VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF COMPACTED FILL. X 1705.6
PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT THE SITE HAVE BEEN PROPERLY PREPARED. 1705.6
INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. X ACI 318: 26.11.1.2(b)
ACI 318: CHG. 20, 25.2, 25.3,
1908.4
26.6.1-26.6.3
INSPECTION OF ANCHORS POST-INSTALLED INSTALLED IN HARDENED CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARD INCLINED ORIENTATIONS TO RESIST SUSTAINED LOADS. X ACI 318: 17.8.2.4(b)
1904.1, 1904.2
VERIFYING USE OF REQUIRED DESIGN MIX. X ACI 318: CH. 19, 26.4.3, 26.4.4
1908.2, 1908.3
PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND
DETERMINE THE TEMPERATURE OF THE CONCRETE. X ACI 318: 26.4, 26.12 1908.10
1908.6, 1908.7,
INSPECTION OF CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES. X ACI 318: 26.5 1908.8
F AND F SLAB ON GRADE FLATNESS TESTING ASTM E1155
F L
REFERENCE IBC
D STANDARD REFERENCE
1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS, AND WASHERS:
APPLICABLE ASTM MATERIAL A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. X
STANDARDS: AISC 360,
B. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED. X SECTION A3.3
2. INSPECTION OF HIGH-STRENGTH BOLTING:
AISC 360, SECTION M2.5
A. SNUG TIGHT JOINTS. X
REFERENCE IBC
STEEL DECK
D STANDARD REFERENCE
1. MATERIAL VERIFICATION OF STRUCTURAL STEEL
A. IDENTIFICATION MARKINGS TO CONFORM TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS. X
APPLICABLE ASTM
B. MANUFACTURER'S CERTIFIED TEST REPORTS. X MATERIAL STANDARDS
SYMBOLS LEGEND
2. INSPECTION OF WELDING:
A. FLOOR AND ROOF DECK WELDS. X AW D1.3
DESCRIPTION SYMBOL
T/X
STEP UP =
SLOPE UP = REVISION CLOUD =
MOMENT
NORTH ARROW =
CONNECTION =
DETAIL
SECTION CUT =
GRADE =
STRUCTURAL FILL =
BUILDING
SECTION CUT =
SUBGRADE =
CONCRETE
IN SECTION =
BRACE =
MASONRY =
FOOTING SIZE = F-X WELDED WIRE FABRIC =
(-X'-X")
COLUMN = C-X
FOOTING STEP =
(-X'-X")
#LTD #THS
ABBREVIATIONS
APPROX APPROXIMATE, APPROXIMATLY
ARCH ARCHITECT, -URAL, -URE
BP BASE PLATE
BLDG BUILDING
B.D. BOTTOM OF
BRG BEARING
C/C CENTER TO CENTER
CFMS COLD FORMED METAL STEEL
CLR CLEAR, -(ANCE)
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONT CONTINUOUS
D DEPTH
DAS DEFORMED ANCHOR STUD
DEG DEGREE
DEMO DEMOLITION
DIM DIMENSION
DL DEAD LOAD
DWG DRAWING
EA EACH
EF EACH FACE
EMBED EMBEDDED
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EXIST EXISTING
(E) EXISTING STRUCTURAL MEMBER
EXP EXPANSION
EXT EXTERIOR
f'c CONCRETE COMPRESSIVE MEMBER
FND FOUNDATION
FIN FINISH
FLR FLOOR
FR FRAMING
FT FOOT
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GYP GYPSUM BOARD
HORIZ HORIZONTAL
HDAB HEAD ANCHOR BOLT
HDAS HEAD ANCHOR STUD
I.F. INSIDE FACE
IN. INCH
JST JOIST
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
MAX MAXIMUM
MIN MINIMUM
MISC MISCELLANEOUS
(N) NEW STRUCTURAL MEMBER
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
O.F. OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
PC PRECAST
PL PLATE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
R RADIUS
REINF REINFORCING, -ED, -MENT
REQ'D REQUIRED
SIM SIMILAR
SP SPACE(S)
SPEC SPECIFICATION(S)
SPEC'D SPECIFIED
STD STANDARD
STIFF STIFFENER
T.O. TOP OF
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
VERT VERTICAL
WWF WELDED WIRE FABRIC
@ AT
OR DIA DIAMETER
# OR NO. NUMBER
DESCRIPTION SYMBOL
ELEVATION =
EL (XXX'-X")
N H OR T
DTL#
SHT#
Project number
Date
Drawn by
Checked by
4202
(C)
THGIRYPOC
CARR ENGINEERING, LLC
ILLINOIS DESIGN FIRM LIC No.
184.007877-0003
3294 Fields Dr.
Bettendorf, IA 52722
(563) 503-6100
MP
83:60:5
6202/9/3
25-134
NOTES &
SYMBOLS
S101
TROPRIA
LANOITANRETNI
YTIC
DAUQ
YTIROHTUA
TROPRIA
NATILOPORTEM
.OC
DNALSI
KCOR
11/04/2025
WDH
CMC
GNIDLIUB
RAGNAH
KRIK
SIONILLI
,ENILOM
NO. DESCRIPTION DATE
1 PERMIT SET 11.04.25
ISOMETRIC VIEW
1
ALL STEEL FRAMING IS TO BE DESIGNED BY THE METAL BUILDING MANUFACTURER