J--WASH RACK MAINTENANCE
| Agency: | INTERIOR, DEPARTMENT OF THE |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Nov 21, 2025 |
| Due Date: | Dec 5, 2025 |
| Solicitation No: | 140R3026Q0006 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Nov 21, 2025 01:39 pm PST
- Original Response Date: Dec 05, 2025 05:00 pm PST
- Inactive Policy: 15 days after response date
- Original Inactive Date: Dec 20, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J036 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SPECIAL INDUSTRY MACHINERY
-
NAICS Code:
- 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
-
Place of Performance:
Proposed Project:
The Bureau of Reclamation, Hoover Dam, Property and Vehicle Maintenance Group of the Hoover Dam, Boulder City, NV requires the current wash rack electric pressure washer and water recycle system to be maintained to factory specifications on a scheduled basis.
The tasks the contractor is to complete are as follows:
1.1.1 Thoroughly test and inspect complete Recycle System including peripheral equipment
1.1.1.1 Inspect any specific faults noted by Warehouse Personnel
1.1.2 Perform any routine maintenance
1.1.3 Test and inspect Reagent pumps
1.1.3.1 Check for air bubbles in lines
1.1.3.2 Adjust pumps settings as needed
1.1.4 Test and inspect skimming system
1.1.4.1 Inspect tank and scum level
1.1.4.2 Inspect skimming pipes
1.1.4.3 Adjust skim timer as needed
1.1.5 Test and inspect sludge removal system
1.1.5.1 Inspect sludge levels in coagulant and separator tanks
1.1.5.2 Inspect sludge socks for efficiency
1.1.5.3 Adjust sludge timer as needed
1.1.6 Check and calibrate pH sensor
1.1.6.1 Clean sensor bulb before calibration occurs
1.1.6.2 If necessary, mix buffer solution to maintain proper pH levels
1.1.7 Inspect and clean collection pit
1.1.7.1 When cleaning out the collection pit, remove all heavier solids and floatable oils and greases from wastewater.
1.1.8 Test and inspect all electrically energized components to include but not limited to:
1.1.8.1 Power switches
1.1.8.2 Breakers
1.1.8.3 Automatic flow control valves
1.1.8.4 Pumps
1.1.8.5 Wiring
1.1.8.6 Motors
1.1.8.7 Float switches
1.1.8.8 Etc..
1.1.9 Inspect all filter media
1.1.9.1 Cleaning filters and media if possible
1.1.9.2 Advise on replacement when necessary Delivered to the Hoover Dam Central Warehouse State Route 172, Boulder City, NV 89005.
The applicable North American Industry Classification System (NAICS) Code 332911, Pressure Control Valves Manufacturing with a size standard of 750 Employees.
Interested firms must submit the following information:
1. Name and address of Firm
2. Phone number
3. Email Address
4. Unique Entity ID Number (Formerly the DUNS Number)
5. Statement as whether the firm manufacturers the end product or not.
6. Identify if the product is American made or not.
7. Size status/SBA certifications (Small business, Women Owned Small Business, HUBZone, Service-Disabled Veteran Owned Small Business, Indian Small Business Economic Enterprise, other)
8. Capability Statement (not to exceed 5 pages). A brief summary of capabilities to include demonstration of the company's capability to perform the work. Previous procurements performed of similar size and complexity to include references with point of contact information. Customary lead times for these types of items. Any known or foreseeable issues with manufacturing these types of items.
9. Estimated delivery date.
All responses must be submitted via email no later than 1600 Pacific Time on 1/5/2026. Email address: nmaye@usbr.gov. Include the reference number (AGBOR300170) in the subject line.
When it is determined that a formal solicitation will be issued, the pre-solicitation notice will be posted on Contract Opportunities at sam.gov web site at http://sam.gov/.
- 500 DATE STREET BUILDING 200
- BOULDER CITY , NV 89005
- USA
- Maye, Noah
- nmaye@usbr.gov
- Phone Number 7022938095
- Fax Number 70229384990000
- Nov 21, 2025 01:39 pm PSTSources Sought (Original)
Related Document
| May 8, 2026 | [Solicitation (Original)] WASH RACK MAINTENANCE |
| May 11, 2026 | [Solicitation (Updated)] J--WASH RACK MAINTENANCE |
| May 19, 2026 | [Solicitation (Updated)] J--WASH RACK MAINTENANCE |
| May 28, 2026 | [Solicitation (Updated)] J--WASH RACK MAINTENANCE |
| Jul 8, 2026 | [Award Notice (Original)] H--WASH RACK MAINTENANCE Base Year and 4 Option Years |
See Also
Follow BORESIGHT KIT CALIBRATION and REPAIR Active Contract Opportunity Notice ID N6833526R1106 Related
DEPT OF DEFENSE
Due by 9/24/2026
Follow annual maintenance and service agreement for autoclave Active Contract Opportunity Notice ID
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION
Follow J--Amendment #3 to 1333MF26Q0108 Active Contract Opportunity Notice ID 1333MF26Q0108 Related Notice
COMMERCE, DEPARTMENT OF
Due by 9/15/2026
Follow R80D Skyraider Maintenance, Training, and Spares Active Contract Opportunity Notice ID FA805126SSRADAS
DEPT OF DEFENSE
Due by 9/17/2026