Description
Follow
Active
Contract Opportunity
Notice ID
36C24526Q0333
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
245-NETWORK CONTRACT OFFICE 5 (36C245)
General Information
Classification
Description
Contact Information
History
- Contract Opportunity Type: Special Notice (Original)
- Original Published Date: Mar 02, 2026 03:45 pm EST
- Original Response Date: Mar 10, 2026 09:00 am EDT
- Inactive Policy: Manual
- Original Inactive Date: May 09, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J061 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
-
NAICS Code:
- 238210 - Electrical Contractors and Other Wiring Installation Contractors
-
Place of Performance:
NOTICE OF INTENT TO SOLE SOURCE A 1 YEAR AWARD TO EATON CORPORATION - FOR REPLACEMENT OF UPS BATTERIES FOR THE HUNGTION VA MEDICAL CENTER LOCATED IN HUNTINGTON WV.
Eaton Corporation
REPRESENTED BY:
Lynn Associates, Inc.
8175 Sheridan Drive
Buidling #1 Suite #1
Buffalo NY 14221
STATEMENT OF WORK PART A GENERAL INFORMATION
A.1 INTRODUCTION The Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704 has eight (8) Uninterruptable Power Source (UPS) units that allow electricity to be supplied to medical center equipment vital to patient care in the event of normal power disruptions. All 8 units require routine maintenance and testing from factory certified technicians to guarantee reliable alternate power 24/7.
EATON UPS MODES have proprietary software that only EATON CORP can service.
A.2 BACKGROUND Failure to have reliable UPS units will prevent other necessary patient care as well as increase the risk of catastrophic failure of the sensitive equipment they protect with severe, patient care consequences such as costly down time to MRI, CAT SCAN and IT servers.
A.3 SCOPE OF WORK Vendor will provide all labor, material, equipment, tools, and supervision necessary to needs a replace UPS units for the IT and CT departments.
Tasks to be accomplished:
Provide 40 new Powerware 9390, Serial EE423CAB13; Model 153302085-002
Provide 40 new Powerware 93PM, Serial ES265UXX06; Model 153000034-002
Vendor will provide:
New Batteries
Removal and EPA approved disposal of old batteries.
Installation utilizing proper torque values (where applicable) and verification of new batteries
Visually inspect conditions and appearance of the following:
Connection terminals inter cell/battery connectors, cables and associated hardware.
Cell/battery covers, containers, and post seals.
Battery racks or cabinets and associated components and hardware.
Cell/battery jar or cover, noting any excessive distortion.
Perform cleaning of all accessible surfaces as required.
Reporting of Battery Update Visit:
The technician(s) will issue the customer a verbal report summarizing the work that was performed, condition of the battery and identifying any critical issues before leaving the customer s site.
A Field Activity Report containing applicable notes and observations will be sent within 5 business days.
Vendor will provide services within 14 days upon contract award.
STATEMENT OF WORK PART C SUPPORTING INFORMATION
C.1 Place of Performance Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington, WV 25704. Delivery vehicles shall keep traffic disruptions to a minimum. Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times.
Eaton Corporation
REPRESENTED BY:
Lynn Associates, Inc.
8175 Sheridan Drive
Buidling #1 Suite #1
Buffalo NY 14221
STATEMENT OF WORK PART A GENERAL INFORMATION
A.1 INTRODUCTION The Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington WV, 25704 has eight (8) Uninterruptable Power Source (UPS) units that allow electricity to be supplied to medical center equipment vital to patient care in the event of normal power disruptions. All 8 units require routine maintenance and testing from factory certified technicians to guarantee reliable alternate power 24/7.
EATON UPS MODES have proprietary software that only EATON CORP can service.
A.2 BACKGROUND Failure to have reliable UPS units will prevent other necessary patient care as well as increase the risk of catastrophic failure of the sensitive equipment they protect with severe, patient care consequences such as costly down time to MRI, CAT SCAN and IT servers.
A.3 SCOPE OF WORK Vendor will provide all labor, material, equipment, tools, and supervision necessary to needs a replace UPS units for the IT and CT departments.
Tasks to be accomplished:
Provide 40 new Powerware 9390, Serial EE423CAB13; Model 153302085-002
Provide 40 new Powerware 93PM, Serial ES265UXX06; Model 153000034-002
Vendor will provide:
New Batteries
Removal and EPA approved disposal of old batteries.
Installation utilizing proper torque values (where applicable) and verification of new batteries
Visually inspect conditions and appearance of the following:
Connection terminals inter cell/battery connectors, cables and associated hardware.
Cell/battery covers, containers, and post seals.
Battery racks or cabinets and associated components and hardware.
Cell/battery jar or cover, noting any excessive distortion.
Perform cleaning of all accessible surfaces as required.
Reporting of Battery Update Visit:
The technician(s) will issue the customer a verbal report summarizing the work that was performed, condition of the battery and identifying any critical issues before leaving the customer s site.
A Field Activity Report containing applicable notes and observations will be sent within 5 business days.
Vendor will provide services within 14 days upon contract award.
STATEMENT OF WORK PART C SUPPORTING INFORMATION
C.1 Place of Performance Hershel Woody Williams VAMC located at 1540 Spring Valley Drive, Huntington, WV 25704. Delivery vehicles shall keep traffic disruptions to a minimum. Use of any other entry points must be approved by Chief, Engineering Service prior to use. Vendor shall deliver required parts or equipment specified above during approved work times.
Attachments/Links
Contracting Office Address
- 8849 International Drive Suite 215
- LINTHICUM , MD 21090
- USA
Primary Point of Contact
- Bill Pratt
- Billie.Pratt@va.gov
- Phone Number 410-642-2411
Secondary Point of Contact
- Mar 02, 2026 03:45 pm ESTSpecial Notice (Original)
Get Government Bids Like This by Email
Receive daily bid alerts that match your keywords, business categories, and target regions.
See Also
Follow Atmosphere Furnaces Units - Bldg 108 Active Contract Opportunity Notice ID W911KF26QA054
DEPT OF DEFENSE
Due by 9/25/2026
Follow J065--Emergency Repair to Philips Radiology Digital Radiography Active Contract Opportunity Notice ID
VETERANS AFFAIRS, DEPARTMENT OF
Follow BORESIGHT KIT CALIBRATION and REPAIR Active Contract Opportunity Notice ID N6833526R1106 Related
DEPT OF DEFENSE
Due by 9/24/2026
Follow REPAIRS TO FIRE SUPPRESSION TANK RICH Active Contract Opportunity Notice ID 140P4226R0031
INTERIOR, DEPARTMENT OF THE
Due by 9/21/2026
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.