J065--HOOD FUME MAINTENANCE - Base plus 4 (8/1/24 - 7/31/29

Agency: VETERANS AFFAIRS, DEPARTMENT OF
State: Arizona
Type of Government: Federal
FSC Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted Date: Apr 23, 2024
Due Date: May 7, 2024
Solicitation No: 36C26224Q0558
Bid Source: Please Login to View Page
Contact information: Please Login to View Page
Bid Documents: Please Login to View Page
Follow
J065--HOOD FUME MAINTENANCE - Base plus 4 (8/1/24 - 7/31/29
Active
Contract Opportunity
Notice ID
36C26224Q0558
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
262-NETWORK CONTRACT OFFICE 22 (36C262)
Looking for contract opportunity help?

APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.

APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.

The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).

General Information
  • Contract Opportunity Type: Presolicitation (Updated)
  • All Dates/Times are: (UTC-06:00) MOUNTAIN STANDARD TIME, DENVER, USA
  • Updated Published Date: Apr 22, 2024 04:53 pm MDT
  • Original Published Date: Feb 05, 2024 02:15 pm MST
  • Updated Response Date: May 07, 2024 04:00 pm MDT
  • Original Response Date: Mar 04, 2024 04:00 pm MST
  • Inactive Policy: Manual
  • Updated Inactive Date: May 30, 2024
  • Original Inactive Date: May 03, 2024
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 811210 - Electronic and Precision Equipment Repair and Maintenance
  • Place of Performance:
    Southern Arizona Healthcare System (SAVAHCS) Tucson , AZ 85723
    USA
Description

D.1 STATEMENT OF WORK





The contractor shall provide all labor, personnel, equipment, transport of materials to certified lab, reporting of results, disposal of hazardous/nonhazardous waste materials, proof of licensing, documentation of required service and permits when required to provide testing, tools, materials, supervision, and other items necessary to provide annual preventive maintenance and corrective repair service on-site for the equipment and systems listed in Section 3 below for the Southern Arizona VA Health Care System (SAVAHCS) and as defined in this Statement of Work (SOW).






  1. SERVICE/WORK TO BE PERFORMED:


    • The contractor will perform on-site certification testing on equipment/systems as provided for in the contract agreement. Since there are multiple types of hoods and certification requirements, the standards for each device and room are listed in the equipment table below. Service engineer/technicians must be Controlled Environment Testing Association (CETA) registered cleanroom certification professionals.










    • Travel and labor included.

    • All test equipment requiring calibration is traceable through the National Bureau of Standards.

    • Certification:














      1. All primary engineering controls (PEC) and secondary engineering controls (SEC) and passthrough certification are completed no less than every 6 months or whenever changes to the area such as redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room that could affect airflow or air quality. PEC, SEC and passthroughs will be retested if they fail to meet standards of USP 797 and USP 800. Certification will occur under dynamic operating conditions. Testing for certification includes:

        1. Airflow testing (PEC and SEC)

        2. HEPA filter integrity testing (PEC and SEC)

        3. Total particle count testing (PEC, SEC and passthroughs)

        4. Dynamic airflow smoke pattern testing (PEC and SEC)

        5. Viable air sampling (PEC, SEC and passthroughs)
















      1. Viable surface sampling (SS) of all PEC and SEC are performed no less than monthly and after every personnel medial fill (MF) testing. Compounders and personnel with direct observation of compounding will need to be retested if they fail to meet standards of USP 797. IV room, anteroom, hazardous drug (HD) room and segregated compounding area (SCA) PEC, all SEC and passthroughs will need to be retested if viable SS testing fails to meet standards of USP 797.














      1. Personnel gloved fingertip (GFT) testing shall occur no less than every 6 months for compounders and no less than annually for direct observation of compounding. Personnel GFT testing is performed after donning of garb and MF testing. Personnel GFT testing is performed three times after each donning of garb for initial personnel certification and once for recertification. Compounding and personnel with direct observation of compounding will need to be retested if they fail to meet USP 797 standards.














      1. Environmental wipe sampling for hazardous drug residue is performed no less than every 6 months or more frequently as needed to verify containment per the standards of USP 800. The kits used to complete wipe sampling must be verified prior to use to ensure the sensitivity and validity of the methods and reagents used to recover a specific percentage of known marker drugs. A minimum of 6 surface samples will be completed per certification. Facilities can elect to expand beyond the minimum number of samples, but coordination with the contractor will be required prior to the certification visit. Surface sampling should include the following areas:
















        1. Interior of containment primary engineering control (C-PEC) and any equipment contained inside the C-PEC

        2. Pass-through chambers

        3. Surfaces in staging or work areas near C-PEC

        4. Areas adjacent to C-PECs (e.g., floors directly under C-PEC, staging, and dispensing area)

        5. Areas immediately outside the hazardous drug buffer room or C-SCA

        6. Patient administration areas
















      1. No less than 5 commonly used chemotherapy drugs will be tested at your facility at the time of testing.










  1. EMERGENCY LINE ITEM:








    • Service calls with on-site response within 24 hours (Monday to Friday 8:00 AM to 5:00 PM). Emergency Designated Response time 24 hours unless otherwise agreed upon by COR or designee: Completed as needed and price added separately.










    • Response: All requests for repair service will be considered requests for emergency service unless a statement to the contrary is made by the COR, POC or designee. A competent service representative adequately equipped with tools, test instruments, service manuals, and repair parts will arrive at the SAVAHCS within the designated response time. The service representative may contact VA staff by phone before arrival at the SAVAHCS. Such contacts, however, will not serve to alter the requirements for arrival on-site except when the request for service is withdrawn by designee.








  1. PERFORMANCE:








    • Hours: Normal duty hours are 8:00 a.m. through 4:30 p.m., Monday through Friday, not including federal holidays. Whenever contact with Operations Supervisor is required outside of normal duty hours, the Utility System Repair Operator (USRO) may be contacted as an alternate. The hospital operator at extension "0" can contact the USRO via radio.

    • Preventive maintenance will be scheduled with a contact person as assigned by the Contracting Officer’s Representative (COR), Point of Contact (POC) or designee. This PM work must be completed in the month specified during the request unless another date is agreed upon by COR or designee. The Operations supervisor can be contacted at (520) 792-1450 ext. 15020. All contractor personnel (without exception) must report to the Maintenance & Operations Department, Bldg. 2-room B17, to sign in and receive a contractor identification badge before any work is performed and return to the same location to sign out and turn-in said badge along with the documented service report (as described in section 4, DOCUMENTATION) for the service performed.

    • Noncontract Charges: The contractor shall not perform any service that will result in additional charges without prior approval from the Contracting Officer.

    • Payment: Payment will be made in Tungsten, and upon receipt of a properly prepared invoice which references the period for which payment is due, the contract number and/or assigned purchase order number. The invoice must include the correct payment address.

    • Waste Removal: The contractor is responsible to remove and properly dispose of all waste related to the services provide on-site at SAVAHCS.

    • Failure to carry out the above procedures will be considered as a failure to document the service visit and will constitute a failure to perform.

    • All shipping for parts will be included in the cost of the contract.








  1. DOCUMENTATION:








    • Service reports will be provided for all service activities including preventive maintenance, emergency repair, and safety inspections, and must contain the following information:








    1. Date(s) and time of service.

    2. Complete description of equipment serviced including model number and serial number.

    3. Complete description of equipment services performed including upgrades, updates and software changes made.

    4. Complete list of all materials, parts, or assemblies installed or replaced including serial numbers of parts where applicable.

    5. A statement of the complaint that initiated the service call.

    6. Total standard labor hours, total overtime/premium hours, and total travel hours expended during the repair.

    7. Last calibration date of service equipment.



  • For each PEC passing the required certification tests, the contractor will supply each unit with a certification sticker with the following information:

    • Company name and contact information.

    • Unit make, model and serial number.

    • Report number

    • Location (e.g., building, room number)

    • Certification date

    • Recertification date

    • Technician signature








  1. REMOVAL OF EQUIPMENT:








    • Whenever possible, all repairs and preventive maintenance will be performed at the SAVAHCS. When that is not possible, the COR, POC or designee may give approval for service work to be done at another location. All transportation charges will be borne by the contractor.

    • VA property may not be removed from the SAVAHCS prior to execution, and approval of all documents as required by Logistics Service. Computer hard drives and other storage media items may not leave VA property.

    • Requirements for service reports for designated equipment not at this location are the same as for work done on-site. Service reports for incoming equipment will be presented for signature at the time of delivery. If equipment is returned via commercial carrier, the service report may be included with the shipment.



  1. GOVERNMENT REPAIRS: Government employees will work on contract equipment only with authorization of the contractor or following the failure of the contractor to respond. The government is not obligated to perform any work on contract equipment.

  2. PRIOR INSPECTION OF EQUIPMENT: Potential contractors may, at their own expense, inspect equipment covered by this solicitation (ref 52.237-1 SITE VISIT). Arrangements must be made in advance with Operations Supervisor. (see section 3, above).

  3. GUARANTEE: The contractor will guarantee workmanship and all parts furnished by the contractor for a period of not less than 90 days.






  1. EQUIPMENT:





EE#



LOC.



MAKE



MDL



SN



Certification Standards



EQU. TYPE



AREA



92627



BA080-57



Baker



Edgegard VF401



128826



Per Manufacturer's Specifications, CETA Applications Guide 002-2006; Per ISO 14644-1



Positive Isolator



Pharm



93003



BA080-57



Baker



Edgegard VF601



130072



Per Manufacturer's Specifications, CETA Applications Guide 002-2006; Per ISO 14644-1



Positive Isolator



Pharm



88030



BA080-57



Baker



SG-304



126553



Per Manufacturer's Specifications, CETA Applications Guide 002-2006; Per ISO 14644-1



Negative Isolator



Pharm



98084



BA080-57



Baker



CS-500



125183



Per Manufacturer's Specifications, CETA Applications Guide 002-2006; Per ISO 14644-1



Negative Isolator



Pharm



92626



BA080-57



Baker



Edgegard VF401



128825



Per Manufacturer's Specifications, CETA Applications Guide 002-2006; Per ISO 14644-1



Positive Isolator



Pharm



114338



BA086



Baker



BCG 401



143302



Per USP 797/800



BSC Biochemgard



Pharm



Do not have yet



BA084



Baker



BCG 401



Do Not Have yet



Per USP 797/800



BCG Biochemgard



Pharm



57903



0B138A-57



BSL III Hood Room



Filters



HEPA



Testing includes air volume, air exchange rates, room pressurization, HEPA filter leak testing



BSL III



Lab



55366



0B139-57



Ante Room



Filters



HEPA



Testing includes air volume, air exchange rates, room pressurization, HEPA filter leak testing



BSL III



Lab





0B140-57



BSL III Lab Room



Filters



HEPA



Testing includes air volume, air exchange rates, room pressurization, HEPA filter leak testing



BSL III



Lab



57903



0BA015-57



Extraction



Filters



HEPA



Testing includes air volume, air exchange rates, room pressurization, HEPA filter leak testing



BSL III



Lab



76270



107-10



NUAIRE



NU-437-400



163682061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



76272



107-10



NUAIRE



NU-437-400



163684061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



53702



110-10



BAKER



SG403A



94853



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



76256



110-10



NUAIRE



NU-437-500



163685061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



76269



110-10



NUAIRE



NU-430-600



163698061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II B Direct Inflow Method



Research



76261



112-78



NUAIRE



NU-437-600



163690061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



76263



113-10



NUAIRE



NU-435-400



163692061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II B Direct Inflow Method



Research



76259



113-78



NUAIRE



NU-437-500



163688061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



76260



114A-78



NUAIRE



NU-437-500



163689061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



76262



115-78



NUAIRE



NU-437-600



163691061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Research



53149



116-78



Fisher Scientific



115V



80383682



Smoke Containment/Face Velocity



Fume Hood



Research



76264



116-78



NUAIRE



NU-435-400



163693061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II B Direct Inflow Method



Research



56724



138A-78



Thermo Electron



C8004055



68013



AIHA/ANSI Lab Ventilation Requirements



Downdraft Table



Research



30029



111-78



LABCONCO



6900000



255087



Ductless-Smoke Containment/Face Velocity



Fume Hood



Research



86409



138-78



SAFETY LAB



112537002



171150096



Walk-In



Walk-in



Research



81099



107-10



LABCONCO



3955200



160728749B



Smoke Containment/Face Velocity



Fume Hood



Research



76271



111-78



NUAIRE



NU-3437-400



163683061014



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II, Type A2 Biological Safety Cabinet



Research



76658



0B146-57



MOPEC



BF100



BF100H14006



Per Manufacturer's Specifications; Directional Smoke/Face Velocity



Fume Hood



Lab



86323



0B147-57



NUAIRE



NU-435-400



176331092816



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II B Direct Inflow Method



Lab



34107



0B138-57



NUAIRE



NU-427-400



77388AFR



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II B Direct Inflow Method



Lab



61599



0B133-57



NUAIRE



NU-425-600



140865102610





BSL III



Lab



34546



0B138-57



NUAIRE



NU-427-400



82675AGR



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II B Direct Inflow Method



Lab



96063



B146-57



MOPEC



MB1060R



MB1060R0135661001



Smoke Containment/Face Velocity



Fume Hood



Lab



96064



B146-57



MOPEC



MB1060R



MB1060R0135661002



Smoke Containment/Face Velocity



Fume Hood



Lab



62974



0B146-57



Air Science



P5-36



P66066



Ductless-Smoke Containment/Face Velocity



Fume Hood



Lab



73235



0BA028A-38



Labconco



3440001



130171290C



Per Manufacturer's Specifications; Per NSF Standard No. 49



Class II A Direct Inflow Method



Lab



102996



0B133-57



Thermofisher Scientific



1300



300429464



Per Manufacturer's Specifications; Per IES-RP-CC-001



Class I Biological Safety Cabinet



Lab



103551



0BA045-57



Thermofisher Scientific



1100-2-C



210514





Fume Hood



Lab



39668



0BA028B-38



Air Clean Sys



AC648LFUVC



AC648LFUVC2356



Per Manufacturer's Specifications; Per IES-RP-CC-001



Class I Biological Safety Cabinet



Lab



104536



181U-57



PCI



G18-E



121-0019



Smoke Containment/Face Velocity



Fume Hood



SPS



55283



181U-57



PCI



G14KA



29590



Smoke Containment/Face Velocity



Fume Hood



SPS



75491



2756-80



Air Science



P30



P70084



Chemical Fume



Fume Hood



Derm



76657



227-57



Mopec



BF100



BF100H14005



Per Manufacturer's Specifications; Directional Smoke/Face Velocity



Fume Hood



OR



66199



A109-38



Comecer



FHR1 50 LAR



40C1C\0111\V11246



Chemical Fume



Fume Hood



Radiology


Attachments/Links
Contact Information
Contracting Office Address
  • 335 E. German Rd SUITE 301
  • Gilbert , AZ 85297
  • USA
Primary Point of Contact
Secondary Point of Contact


History

Related Document

May 7, 2024[Presolicitation (Updated)] J065--HOOD FUME MAINTENANCE - Base plus 4 (8/1/24 - 7/31/29

Sign-up for a Free Trial, Government Bid Alerts

With Free Trial, you can:

You will have a full access to bids, website, and receive daily bid report via email and web.

Try One Week FREE Now

See Also

Water Conditioning and Treatment Services for HVAC Equipment and Systems BPM006201 Water Conditioning

State Government of Arizona

Bid Due: 5/15/2024

Follow Chemical Fire Suppression Services - Sources Sought Active Contract Opportunity Notice ID

DEPT OF DEFENSE

Bid Due: 5/30/2024

Rolls Royce 250-C47B Engine Overhaul, Repair and Maintenance BPM006225 Rolls Royce 250-C47B Engine

State Government of Arizona

Bid Due: 5/31/2024

240144-C TIRES ON AND OFF-ROAD FLEET AND ROADSIDE SERVICE RFB Maricopa County Arizona

Maricopa County

Bid Due: 5/21/2024