J030--Generator-ATS Maintenance (VA-27-00002745)
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Set Aside: | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| Posted Date: | Sep 16, 2026 |
| Due Date: | Oct 19, 2026 |
| Solicitation No: | 36S79726Q0006 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- Updated Published Date: Sep 16, 2026 03:16 pm CDT
- Original Published Date: Aug 25, 2026 02:54 pm CDT
- Updated Date Offers Due: Oct 19, 2026 04:00 pm CDT
- Original Date Offers Due: Sep 28, 2026 04:00 pm CDT
- Inactive Policy: Manual
- Updated Inactive Date: Dec 03, 2026
- Original Inactive Date: Nov 27, 2026
-
Initiative:
- None
- Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Product Service Code: J030 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MECHANICAL POWER TRANSMISSION EQUIPMENT
-
NAICS Code:
- 561210 - Facilities Support Services
-
Place of Performance:
1st Ave., One Block N of 22nd Bldg 37 Hines , 60141
What are the hours of operation for Generator Maintenance? This is in the SOW
Can you provide a Document with each Back-up Generator Model # s &Serial # s? This is Attachment A of the package
Please Confirm the Voltage of the Generators? 480 and 240
Regarding Contractor Provided Consumables, many of the items listed are typically repairs quoted and approved before work proceeds on this and some parts(hoses and belts). As an outside vendor there is no way to effectively build this into your maintenance plan to guarantee effective cost for both the vendor and for Edward Hines VA. We request this section is altered to allow for these costs to be sectioned out for repairs and for one annual service to replace filters and oil. See Attachment B.
How many Generators have Diesel Engines? All of them
Are there any Generators with difficulty accessing (Roof, Parking Garage, Basement)? If so, which units are they? NO
Are your Generators within 50 ft of the Entry Door, where our truck will be parked? Yes
Are the Annual Load Tests performed with your Minor B-PMs? No
Can I get the age of each equipment if possible? See Attachment A
Please clarify the Unscheduled Repair CLIN amount. Is the stated $50,000 intended to mean $50,000 per contract year? This is just a funding item for me to populate an unscheduled maintenance clin for me to address items the break.
Where should emergency travel and labor be priced? All previous contracts has local labor. Never had this issue. Build it in your quote.
Will VA furnish diesel consumed during inspections? VA furnishes Fuel for the generators Period.
Can you provide any previous maintenance reports, emergency calls, major repairs, etc.? After Award.
Consumables Attachment
Section 2.1 states Replace PM Consumables as required and references Attachment 1, while the solicitation package includes Generator Consumables Attachment B. Please confirm that Attachment B is the document intended by the reference to Attachment 1, and that the consumables identified in Attachment B are to be furnished and replaced by the contractor as required during preventive maintenance and included within the applicable PM CLIN pricing. Consumables are outlined in Attachment B.
Work Hours / Load Bank Testing
Section 4.3 identifies the monthly PM for the two 600 kW generators and one 500 kW generator as occurring on the second Tuesday of each month from 4:00 AM to 7:00 AM, while the 1250 kW and 750 kW generators may be serviced during normal business hours. Please confirm whether the annual load-bank testing, ATS maintenance, sampling, and other annual maintenance activities may also be performed during normal business hours unless otherwise coordinated with the COR.
The 600 s, and 500 are backing up a critical production line that is old and has issues during power transfers. We require them and their associated equipment to be cycled or maintained prior to that department s workday start, so they can start the production line on time with no delay. This department is the Consolidated Mail Order Pharmacy (CMOP). All the generator maintenance is to be performed on the second Tuesday of each month, we need the CMOP Generators started and done first.
Transformer Annual Inspection and IR Scan
The scope includes quarterly energized transformer inspections as well as an annual inspection that includes additional maintenance activities and an IR scan. The pricing schedule only provides a quarterly transformer CLIN with a quantity of four. Please confirm whether the annual transformer inspection and IR scan are to be included within the pricing for the four quarterly inspections, with one quarterly service incorporating the annual work, or if the annual service is to be priced separately.
Please confirm the intended operating condition for the annual IR scan, as it appears under the annual de-energized inspection section.
Annual Transformer and ATS IR Scanning Procedure
The annual infrared (IR) scan of transformer lugs and automatic transfer switches (ATSs) is to be completed while the equipment is energized, prior to any deenergizing procedures. This approach allows for the identification of potential faults under operating conditions, ensuring that any issues are detected before maintenance begins.
Once the IR scan is performed, any necessary repairs should be made during the scheduled deenergized maintenance period. This ensures that faults identified during the scan can be addressed safely while the equipment is not under load.
The IR scan should occur once each year and, whenever possible, should be scheduled close to the time of the annual deenergized maintenance. This coordination facilitates efficient fault resolution and minimizes downtime.
In the event of an emergent issue identified during the scan, immediate corrective action will be taken to address the problem as soon as possible, regardless of the scheduled maintenance cycle.
- P.O. BOX 76
- HINES , IL 60141
- USA
- Michelle Williams
- michelle.williams4@va.gov
- Phone Number 708.786.7565
- Sep 16, 2026 03:16 pm CDTCombined Synopsis/Solicitation (Updated)
- Aug 31, 2026 01:24 pm CDT Combined Synopsis/Solicitation (Updated)
- Aug 31, 2026 01:24 pm CDT Combined Synopsis/Solicitation (Updated)
- Aug 25, 2026 02:54 pm CDT Combined Synopsis/Solicitation (Original)
Related Document
| Aug 25, 2026 | [Combined Synopsis/Solicitation (Original)] J030--Generator-ATS Maintenance (VA-27-00002745) |
| Aug 31, 2026 | [Combined Synopsis/Solicitation (Updated)] J030--Generator-ATS Maintenance (VA-27-00002745) |
See Also
Follow Modernizing the Naval Enterprise Digital Environment Active Contract Opportunity Notice ID N6175027R0000
DEPT OF DEFENSE
Follow J065--Pyxis Carousel Maintenance Active Contract Opportunity Notice ID 36C25527Q0054 Related Notice Department/Ind.
VETERANS AFFAIRS, DEPARTMENT OF
Due by 11/23/2026
Follow USNS SOJOURNER TRUTH (T-AO 210) PSA Active Contract Opportunity Notice ID N3220527R6004
DEPT OF DEFENSE
Follow T-6/T-34 Aircraft Maintenance and Contractor Logistics Support (CLS): Request for Proposal (RFP)
DEPT OF DEFENSE
Due by 12/08/2026