J065--FY27 SERVICES (BASE+4) - Canon CT Service Contract
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Virginia |
| Type of Government: | Federal |
| FSC Category: |
|
| Posted Date: | Oct 9, 2026 |
| Due Date: | Oct 16, 2026 |
| Solicitation No: | 36C24227Q0046 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Oct 09, 2026 12:38 pm EDT
- Original Response Date: Oct 16, 2026 12:00 pm EDT
- Inactive Policy: Manual
- Original Inactive Date: Dec 15, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
-
NAICS Code:
- 811210 - Electronic and Precision Equipment Repair and Maintenance
-
Place of Performance:
Department of Veterans Affairs Buffalo VA Medical Center Buffalo , 14215
B.2.1 GENERAL
This firm fixed price requirement is for the annual preventative maintenance of two Canon/Toshiba CT machines, model: Aquilion Prime 160, serial numbers FLB16Y2138 and FLB1742181 located at the Buffalo VA Medical Center 3495 Bailey Avenue Buffalo NY 14215, from 11/01/2027 to 10/31/2027 to include four (4) option years.
B.2.2 SCHEDULE
1. All work shall take place during normal business hours, Monday - Friday, 8:00am-5:00pm, excluding the following federal holidays.
a. New Year s Day
b. Birthday of Martin Luther King Jr.
c. Presidents Day
d. Memorial Day
e. Juneteenth
f. Independence Day
g. Labor Day
h. Columbus Day
i. Veterans Day
j. Thanksgiving Day
k. Christmas Day
l. Any other day deemed a Holiday by the President B.2.3 EQUIPMENT LIST
Serial Number
Make/Model
FLB16Y2138
Aquilion Prime 160
FLB1742181
Aquilion Prime 160D B.2.4 ANNUAL PREVENTATIVE MAINTENACE OF CANON/ TOBISHA CT MACHINES
The contractor shall ensure the CT machines are properly maintained and repaired in a timely manner.
The contractor shall perform preventative maintenance service four times a year for the two (2) Aquilion Prime 160 CT machines at the Buffalo VA Medical Center.
The contractor shall service and provide replacement of X-ray tubes.
The contractor shall provide new, standard parts that comply with applicable performance and reliability specifications.
The contractor shall provide parts that shall be warranted to be free from defects in material and workmanship for a period of twelve (12) months from the date of installation.
The Contractor warrants that all repair services shall be performed according to current manufacturer s specifications for such equipment.
The Contractor warrants that the labor and services shall be performed in a good and workmanlike manner and shall comply with all applicable laws and regulations.
The contractor shall provide a firewall between hospital network and CT machines.
B.2.5 RESPONSE TIME
Onsite Response
The contractor shall provide the Field Service Engineer (FSE) on-site response time of 4-6 hours. and 30-minute telephone response time for corrective maintenance repairs.
Telephone Response
The contractor shall provide the Field Service Engineer (FSE) a telephone response time within 30 minutes for corrective maintenance repairs.
B.2.6 PATIENT PRIVACY
The Contractor shall abide by the rules and regulations that relate to the privacy, security and confidentiality of patient information and patient-identifiable information.
B.2.7 GENERAL LIABILITY
The Contractor shall maintain at its sole cost and expenses, commercial general liability insurance for bodily injury and property damage liability. B.2.8 SERVICE DOCUMENTATION
Upon completion of the repair, the contractor shall provide an electronic copy of the field service report (FSP) to the COR and applicable VA HTM technician.
- 113 HOLLAND AVE
- ALBANY , NY 12208
- USA
- Kaitlyn Morgan
- Kaitlyn.Morgan2@va.gov
- Phone Number 703-986-6136
- Oct 09, 2026 12:38 pm EDTSources Sought (Original)
Related Document
| Oct 21, 2026 | [Presolicitation (Original)] J065--FY27 SERVICES (BASE+4) - Canon CT Service Contract |
| Oct 21, 2026 | [Presolicitation (Original)] J065--FY27 SERVICES (BASE+4) - Canon CT Service Contract |
| Oct 21, 2026 | [Presolicitation (Original)] J065--FY27 SERVICES (BASE+4) - Canon CT Service Contract |
See Also
Follow J065--Reverse Osmosis Systems Maintenance Services Active Contract Opportunity Notice ID 36C25027Q0051 Related
VETERANS AFFAIRS, DEPARTMENT OF
Due by 11/16/2026
Follow FY27 HVAC Maintenance Service Active Contract Opportunity Notice ID PANMCC26P0000056336 Related Notice
DEPT OF DEFENSE
Due by 11/13/2026
Follow CVN 75 RCOH Painting, Decking and Lagging Active Contract Opportunity Notice ID
DEPT OF DEFENSE
Due by 11/16/2026
Follow J065--RO Equipment Maintenance Active Contract Opportunity Notice ID 36C25027Q0051 Related Notice Department/Ind.
VETERANS AFFAIRS, DEPARTMENT OF
Due by 11/16/2026