J041--Chiller Shaft Replacement John D. Dingell VA Medical Center
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Virginia |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Dec 10, 2024 |
| Due Date: | Dec 18, 2024 |
| Solicitation No: | 36C25025Q0167 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Sources Sought (Original)
- Original Published Date: Dec 10, 2024 10:39 am EST
- Original Response Date: Dec 18, 2024 03:00 pm EST
- Inactive Policy: Manual
- Original Inactive Date: Feb 16, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
-
NAICS Code:
- 238220 - Plumbing, Heating, and Air-Conditioning Contractors
-
Place of Performance:
John D. Dingell VA Medical Center Detroit , 48201USA
General Information
Engineering is requesting a Service Contract for the Removal and Replacement of shaft seal that is leaking oil on Chiller #1. York: YKMQMSH9, S/N: SAXM833730 Chiller. Locate in the Energy Center, room EC103 at the John D. Dingell VA Medical Center. The Contractor shall provide all parts, materials, labor, supervision, test equipment, technical manuals, and transportation necessary to perform the work required. The Contractor shall use/follow only original equipment manufacturer (OEM) parts/materials/recommendations and applicable national, state, county, and local codes, and must have Environmental Protection Agency (EPA) recovery license.
The Contractor shall use a certified Johnson Controls/York chiller mechanic with verified
credentials to perform the services and technical expertise that is required with Johnson
Controls and York products.
The contractor shall use only original equipment (OEM) parts and materials for this
requirement. The contractor shall follow all applicable national, state, county, and local
codes having jurisdiction and shall match existing building construction and standards,
at the John D. Dingell Veterans Affairs VA Medical Center and VA standards.
Contractor shall perform the following work required during the period of performance:
Shaft Seal replacement:
Properly LO/TO chiller.
Recover and store approximately 2600lbs of refrigerant
Charge the chiller with nitrogen to atmospheric pressure.
Remove the defective shaft seal.
Install new OEM shaft seal
Check the motor/compressor shaft alignment, compressor shaft run-out and thrust tolerances.
If the measurements are within specification, a new shaft seal will be installed.
If the measurements are out of spec. disassembly/repair will be quoted separately.
The chiller will be pressurized, and leak checked to 500 microns at a minimum, prior to being dehydrated and evacuated.
Charge the chiller with the recovered refrigerant.
Additional refrigerant may be needed and will be charged separately.
Once the machine is started, the oil charge will be verified, and oil added as
needed. Check new seal to ensure there is no oil leak.
If this is a service your business can provide, respond to this Sources Sought by Wednesday, December 18, 2024; 3:00 P.M. Eastern time. Responses should include: (1) Business Name and Address (2) Point of Contact Name, Phone Number, and E-mail Address (3) SAM UEI and NAICS code (4) Business Size SMALL or LARGE (5) Type of Business SERVICE DISABLED VETERAN OWNED, VETERAN OWNED, 8A, HUBZone, WOMEN-OWNED etc. (6) Applicable GSA/FSS Contract Number (if applies). All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above noted service. E-mail responses to: Alexis Alexander, at Alexis.Alexander1@va.gov. (Note: This is NOT A REQUEST FOR QUOTE or an announcement of a solicitation.)
- VISN 10 CONSOLIDATED CONTRACTING 4100 WEST 3RD STREET
- DAYTON , OH 45428
- USA
- Alexis S. Alexander
- Alexis.Alexander1@va.gov
- Phone Number 734-222-7169
- Dec 10, 2024 10:39 am ESTSources Sought (Original)
Related Document
| Dec 20, 2024 | [Presolicitation (Original)] J041--Chiller Shaft Replacement John D. Dingell VA Medical Center |
| Dec 27, 2024 | [Solicitation (Original)] J041--Chiller Shaft Replacement John D. Dingell VA Medical Center |
| Jan 3, 2025 | [Solicitation (Updated)] J041--Chiller Shaft Replacement John D. Dingell VA Medical Center |
| Jan 27, 2025 | [Award Notice (Original)] J041--Chiller Shaft Replacement John D. Dingell VA Medical Center |
See Also
Virginia Lottery iLottery System, Services, and Su... Status: Open RFP 123127-2 Virginia State
State Government of Virginia
Due by 9/23/2026
Follow J059--Automatic Transfer Switch and Isolation Panel Service | Leavenworth VAMC | Active
VETERANS AFFAIRS, DEPARTMENT OF
Due by 10/02/2026
Follow Getinge Preventive Maintenance Active Contract Opportunity Notice ID HT9410 Related Notice Department/Ind.
DEPT OF DEFENSE
Due by 9/16/2026
Biomedical Preventative Maintenance and Repair Ser... Status: Open IFB 127602-1 Piedmont Geriatric Hospital
State Government of Virginia
Due by 9/21/2026