J059--bldg 61 feeder breaker repair
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jan 30, 2025 |
| Due Date: | Jan 31, 2025 |
| Solicitation No: | 36C25625P0470 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
Follow
Active
Contract Opportunity
Notice ID
36C25625P0470
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
256-NETWORK CONTRACT OFFICE 16 (36C256)
General Information
Classification
Description
Contact Information
History
- Contract Opportunity Type: Special Notice (Original)
- Original Published Date: Jan 30, 2025 12:43 pm CST
- Original Response Date: Jan 31, 2025 12:00 pm CST
- Inactive Policy: Manual
- Original Inactive Date: Apr 01, 2025
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J059 - MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS
-
NAICS Code:
- 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
-
Place of Performance:
NOTICE OF INTENT TO SOLE SOURCE
SCOPE OF WORK
Furnish all labor and equipment necessary to perform all repair work associated with the repairing the electrical feeder breaker at Building 61 located at the VA Gulf Coast Veterans Health Care System, Biloxi, Mississippi 39531.
Background: Building 61 is the primary electrical switch gear, which controls power to multiple healthcare buildings on the campus and directly affects patient care if not working properly. Recently the VA Medical Center power utility authority, Mississippi Power Company, discovered that (2) feeder breakers were not operating properly and are in need immediate repairs. All work performed on the VA owned electrical switch gear Building 61, must be performed by the power utility authority for the facility. The intent of this requirement is for MPC to make all necessary repairs to (2) feeder breakers as outlined below and to immediately restore the power system to normal operation. It is imperative that power disruption to the facility is minimal.
The work required is listed as follows:
Power/Vac circuit breaker SN:103924-02-001
Provide Technical Specialist, tools, equipment, and parts to repair one GE Power/Vac VBH 15.0-50-3 circuit breaker. The secondary disconnect and damaged pins are to be replaced. The breaker will be repaired, fully tested, adjusted, and returned to service.
Power/Vac circuit breaker SN:103924-02-009
Provide Technical Specialist, tools, equipment, and parts to repair one GE Power/Vac VBH 15.0-50-3 circuit breaker. The secondary disconnect and damaged pins are to be replaced. The breaker will be repaired, fully tested, adjusted, and returned to service.
SCOPE OF WORK
Furnish all labor and equipment necessary to perform all repair work associated with the repairing the electrical feeder breaker at Building 61 located at the VA Gulf Coast Veterans Health Care System, Biloxi, Mississippi 39531.
Background: Building 61 is the primary electrical switch gear, which controls power to multiple healthcare buildings on the campus and directly affects patient care if not working properly. Recently the VA Medical Center power utility authority, Mississippi Power Company, discovered that (2) feeder breakers were not operating properly and are in need immediate repairs. All work performed on the VA owned electrical switch gear Building 61, must be performed by the power utility authority for the facility. The intent of this requirement is for MPC to make all necessary repairs to (2) feeder breakers as outlined below and to immediately restore the power system to normal operation. It is imperative that power disruption to the facility is minimal.
The work required is listed as follows:
Power/Vac circuit breaker SN:103924-02-001
Provide Technical Specialist, tools, equipment, and parts to repair one GE Power/Vac VBH 15.0-50-3 circuit breaker. The secondary disconnect and damaged pins are to be replaced. The breaker will be repaired, fully tested, adjusted, and returned to service.
Power/Vac circuit breaker SN:103924-02-009
Provide Technical Specialist, tools, equipment, and parts to repair one GE Power/Vac VBH 15.0-50-3 circuit breaker. The secondary disconnect and damaged pins are to be replaced. The breaker will be repaired, fully tested, adjusted, and returned to service.
Attachments/Links
Contracting Office Address
- 715 SOUTH PEAR ORCHARD RD., PLAZA 1
- RIDGELAND , MS 39157
- USA
Primary Point of Contact
- Angela Kennedy
- angela.kennedy2@va.gov
- Phone Number (484) 788-1632
Secondary Point of Contact
- Jan 30, 2025 12:43 pm CSTSpecial Notice (Original)
Related Document
| Jan 31, 2025 | [Award Notice (Original)] J059--bldg 61 feeder breaker repair |
Get Government Bids Like This by Email
Receive daily bid alerts that match your keywords, business categories, and target regions.
See Also
Follow R80D Skyraider Maintenance, Training, and Spares Active Contract Opportunity Notice ID FA805126SSRADAS
DEPT OF DEFENSE
Due by 9/17/2026
Follow J--N1 Brake Ring Active Contract Opportunity Notice ID 140R3026Q0137 Related Notice Department/Ind.
INTERIOR, DEPARTMENT OF THE
Due by 10/02/2026
Follow Atmosphere Furnaces Units - Bldg 108 Active Contract Opportunity Notice ID W911KF26QA054
DEPT OF DEFENSE
Due by 9/25/2026
Follow J065--Emergency Repair to Philips Radiology Digital Radiography Active Contract Opportunity Notice ID
VETERANS AFFAIRS, DEPARTMENT OF
* Disclaimer: This website provides information about bids, requests for proposals (RFPs), or requests for qualifications (RFQs) for convenience only and does not serve as an official public notice. Individuals who wish to respond to or inquire about bids, RFPs, or RFQs should contact the relevant government department directly.