J065--ANNUAL TRANSFORMER TESTING & INSPECTION l WICHITA VAMC
| Agency: | VETERANS AFFAIRS, DEPARTMENT OF |
|---|---|
| State: | Federal |
| Type of Government: | Federal |
| FSC Category: |
|
| NAICS Category: |
|
| Posted Date: | Jan 7, 2026 |
| Due Date: | Dec 26, 2025 |
| Solicitation No: | 36C25526Q0128 |
| Original Source: | Please Login to View Page |
| Contact information: | Please Login to View Page |
| Bid Documents: | Please Login to View Page |
Description
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Solicitation (Original)
- Original Published Date: Jan 07, 2026 12:36 pm CST
- Original Date Offers Due: Dec 26, 2025 10:00 am CST
- Inactive Policy: Manual
- Original Inactive Date: Feb 24, 2026
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
-
NAICS Code:
- 335311 - Power, Distribution, and Specialty Transformer Manufacturing
-
Place of Performance:
This statement of work is for the annual inspection and testing of our facility's liquid-filled transformers at the Robert J. Dole VA Medical Center located at 5500 E. Kellogg Ave. Wichita, Kansas 67218. All Inspections shall be done according to IEEE C57 standards and other specifications that may apply, such as NFPA 70B, the Life Safety Code, the Joint Commission on Accreditation of Healthcare Organizations, and VA Regulations.
The contractor shall provide (Base with four option years) all labor, personnel, equipment, tools, materials, supervision, and other items necessary to perform a facility-wide annual transformer inspection.
1. Description of Work
Visual Inspection: Conduct a thorough visual inspection for signs of physical damage, leaks, and corrosion. Visually inspect the transformer grounding.
Oil Sampling and Analysis: Obtain oil samples for chromatographic analysis to assess the oil condition and identify problems.
Record Keeping: Document inspection findings, including test results of the chromatographic analysis.
Contractor will provide one digital copy of the inspection and findings, and one paper copy 3-ringed bound.
2. Requirements
The contractor shall provide all materials, tools, test equipment, and incidentals (travel expenses and transportation charges) necessary to inspect the facility's liquid-filled transformers.
Hours: Work must be performed within the facility's regular work hours, which are Monday through Friday, from 8:00 a.m. to 4:00 p.m. (CST). Scheduling shall be coordinated with the facility maintenance point of contact and will be designated once it is awarded. Services will be confirmed and approved by the facility maintenance Point of Contact or their designated representative. The contractor must report to the Engineering Office, building 20, each day, where he/she will sign in and out at the beginning and end of each day.
Property Damage: The contractor shall take all necessary precautions to prevent damage to any Government property and will notify the contracting officer representative or POC immediately if damages occur. The Contracting Officer will authorize the contractor to remedy the situation in one of the following: be assessed current replacement costs for damaged property, replace damaged property in a timely manner, or correct the damages with like materials at no additional cost.
Identification, Parking, Smoking, and VA Regulations: The contractor's employees shall obtain a contractor's badge from the Engineering office in Building 20. The contractor must always acquire a badge for each worker and ensure that the badge will be worn in a visible location on the worker while on the premises of the VA property. It s the responsibility of the contractor to park in the appropriate designated parking areas. Information on parking is available from the VA Police. The VA will not invalidate or make reimbursement for parking violations of the contractor under any conditions. Smoking is prohibited inside the VA premises. Smoking is available off site or outside the boundaries of the VA premises. Possession of a firearm on the VA premises is prohibited. Enclosed containers, tool bags, or tool kits are subject to search. Violations of VA regulations may result in a citation answerable in the United States District Court.
3. List of liquid filled Transformers on-site
Building 1:
(2) 500KVA 12.5kV/280V
(2) 750KVA 12.5kV/240V
(1) 750KVA 12.5kV/480V
Building 2:
(1) 500KVA 12.5kV/480V
Building 4:
(1) 300KVA 12.5kV/208V
Building 5:
(1) 500KVA 12.5kV/208V
Building 11:
(1) 225KVA 12.5kV/208V
(1) 300KVA 12.5kV/240V
Building 19:
(1) 500KVA 12.5kV/480V
Building 26:
(1) 750KVA 12.5kV/208V
(1) 750KVA 12.5kV/240V
(1) 750KVA 12.5kV/480
Building 34:
(1) 1000KVA 12.5kV/480V
Building 60:
(1) 500KVA 12.5kV/208V
(1) 500KVA 12.5kV/480V
Building 61:
(1) 1000KVA 12.5kV/480V
4. CERTIFICATION AND ACCEDITATION (C&A)
The C&A requirements do not apply to this acquisition. A Security Accreditation Package is not required.
5. Contact Information
Will be released with the contract.
- VA MEDICAL CENTER 4101 SOUTH 4TH STREET
- LEAVENWORTH , KS 66048
- USA
- Aubrey L Visocsky
- Aubrey.Visocsky@va.gov
- Jan 07, 2026 12:36 pm CSTSolicitation (Original)
- Jan 07, 2026 12:34 pm CST Presolicitation (Original)
Related Document
| Jan 7, 2026 | [Presolicitation (Original)] J065--ANNUAL TRANSFORMER TESTING & INSPECTION l WICHITA VAMC |
See Also
Follow Atmosphere Furnaces Units - Bldg 108 Active Contract Opportunity Notice ID W911KF26QA054
DEPT OF DEFENSE
Due by 9/25/2026
Follow J065--Emergency Repair to Philips Radiology Digital Radiography Active Contract Opportunity Notice ID
VETERANS AFFAIRS, DEPARTMENT OF
Follow BORESIGHT KIT CALIBRATION and REPAIR Active Contract Opportunity Notice ID N6833526R1106 Related
DEPT OF DEFENSE
Due by 9/24/2026
Follow REPAIRS TO FIRE SUPPRESSION TANK RICH Active Contract Opportunity Notice ID 140P4226R0031
INTERIOR, DEPARTMENT OF THE
Due by 9/21/2026